Parameters Parameter Specification / Value Application Standard IEC/EN 61643-11 Protection Class / Type Type 2 (Class C per UL 1449 4th Ed.) Rated Voltage (Un) 230/400V AC (50/60 Hz) Maximum Continuous Operating Voltage (Uc) 255V AC (Line to Neutral) Nominal Discharge Current (In) 8/20 µs 5 kA Maximum Discharge Current (Imax) 8/20 µs 20 kA Voltage Protection Level (Up) @ In ≤ 1.5 kV (Line to Neutral) Response Time < 25 ns Short-Circuit Withstand Rating According to IEC 61643-11 Backup Fuse Recommendation gG / gL 16 A (typical, refer to local regulations) Connection / Cross-Section Plug-in terminal / 1.5 - 4 mm² (stranded or solid) Housing Material Thermoplastic (UL94 V-0) Protection Degree (IP) IP20 (when installed in appropriate enclosure) Operating Temperature Range -40 °C to +80 °C Status Indication Visual (color flag: green/red) Mounting DIN-rail mountable (35 mm) Dimensions (H x W x D) Approx. 90 mm x 18 mm x 62 mm (module size)
Specifications Parameter Specification Supply Voltage 24 V DC (±20%) via host device Power Consumption 2.5 W typical, 3.5 W maximum Current Consumption 100 mA typical at 24 V DC Isolation 500 V AC (communication to power circuits) PROFIBUS Interface RS-485 isolated, 9-pin D-Sub female connector Baud Rate 9.6 kbit/s to 12 Mbit/s (auto-detect) PROFIBUS Address 1-125 (set via rotary switch 0-99 + software 100-125) Protocol PROFIBUS DP-V1 (slave) GSD File ABB0809.GSD (specific version required) Data Consistency 8 bytes input / 8 bytes output (configurable) Update Time <10 ms (at 12 Mbit/s) 3. Mechanical Specifications Parameter Specification Dimensions (W×H×D) 45 × 90 × 62 mm (1.77 × 3.54 × 2.44 in) Weight 120 g (0.26 lb) Housing Material Polycarbonate (UL94 V-0) Protection Degree IP20 (for mounting in enclosure) Mounting Direct plug-in to PSR soft starter control unit Connector 9-pin D-sub female (PROFIBUS), screw terminals (aux power) Operating Position Any orientation allowed Color ABB standard gray (RAL 7035) 4. Environmental Specifications Parameter Specification Operating Temperature -20°C to +60°C (-4°F to +140°F) Storage Temperature -40°C to +85°C (-40°F to +185°F) Relative Humidity 5% to 95% non-condensing Altitude ≤2000 m (6560 ft) above sea level Vibration Resistance 5-150 Hz, 1g (IEC 60068-2-6) Shock Resistance 15g, 11ms half-sine (IEC 60068-2-27) Pollution Degree 2 (IEC 60664-1)
Specifications Parameter Specification Supply Voltage 24 V DC (powered from host device) Power Consumption Typically 2-5 W Isolation Voltage 500 V AC (input to output, typical) Communication Speed If PROFIBUS DP: 9.6 kbit/s - 12 Mbit/s If Modbus RTU: 1200 - 115200 baud Data Update Rate ≤ 10 ms (typical for motor data) Number of Process Data Words 4-8 input / 4-8 output words (typical) 3. Mechanical Specifications Parameter Specification Dimensions (W×H×D) Approx. 45 × 90 × 60 mm (estimate) Weight 100-150 g Housing Material Polycarbonate (PC) or Polyamide (PA) Protection Degree IP20 (for enclosure mounting) Mounting Method Direct plug-in to host device Connection Type 9-pin D-sub (if PROFIBUS) or terminal block Operating Position Any (module orientation independent) 4. Environmental Specifications Parameter Specification Operating Temperature -20°C to +60°C (-4°F to +140°F) Storage Temperature -40°C to +85°C (-40°F to +185°F) Relative Humidity 5% to 95% (non-condensing) Altitude ≤ 2000 m above sea level Vibration Resistance 5-2000 Hz, 1g (IEC 60068-2-6) Shock Resistance 15g, 11ms (IEC 60068-2-27) Pollution Degree 2 (IEC 60664-1)
Technical Specifications Parameter Specification Product Code UL-740A-R2A-B024-021 Product Family ABB Symphony / IndustrialIT 800xA / S800 I/O System Module Type Redundant Power Supply Unit Input Voltage 100-240V AC, 50/60 Hz (Universal Input) Output Voltage 24V DC (regulated, for field instruments and I/O modules) Output Current 10A (per module, total 20A in redundant configuration) Redundancy N+1 Redundant Configuration supported (hot-swappable) Efficiency >85% (typical) Protection Overload, Short-circuit, Overvoltage protection Isolation 1500V AC input-to-output isolation Cooling Convection cooling (fanless) Operating Temperature 0°C to +60°C (32°F to 140°F) Relative Humidity 5% to 95% non-condensing MTBF >200,000 hours (calculated per MIL-HDBK-217F) Standards UL 508, CSA C22.2 No. 14, IEC 61131-2, CE, RoHS
Technical Specifications Parameter Specification Product Code PSE142-600-70 Series ABB PSE Electronic Motor Starters Rated Operational Current (Iₑ) 142 A (at 400V, 40°C ambient) Supply Voltage 3-phase, 380 - 690 V AC, 50/60 Hz Motor Power Range Approx. 75 kW (at 400V) Control Supply Voltage (Us) Selectable: 24 V AC/DC, 48-130 V AC, 110-130 V DC, or 200-240 V AC/DC Starting Method Voltage ramp with adjustable initial torque (kick start) and ramp time Starting Current Adjustable, typically up to 400% of motor Full Load Current (FLC) Stopping Method Coast stop (standard); programmable soft stop (optional) Motor Protection Class 10 electronic overload protection, phase loss/imbalance, jam protection, underload, PTC thermistor input Enclosure IP00 (Open Type) for panel mounting Ambient Temperature -25°C to +60°C (operating), derating above +40°C Communication Optional plug-in communication modules (PROFIBUS DP, Modbus RTU, DeviceNet) Standards & Approvals IEC/EN 60947-4-2, UL 508, CE, cULus
Technical Specifications Parameter Specification Product Code PSTX170-600-70 Series ABB PSTX Medium Voltage Soft Starters Rated Voltage 3300 V / 6000 V (switch-selectable) Rated Current 170 A (continuous at 40°C) Starting Current Adjustable, typically 200% - 450% of motor Full Load Current (FLC) Motor Power Range Approx. 850 - 1120 kW (dependent on voltage & motor PF) Control Supply Voltage 110-120V AC or 220-240V AC, 50/60 Hz (configurable) Starting Time Adjustable from 5 to 120 seconds Stopping Time Adjustable soft-stop (optional) Cooling Method Forced air cooling (integrated fans) Enclosure IP00 / Open Type (for cabinet installation) Ambient Temperature 0°C to +40°C (32°F to 104°F) for full rating; up to +50°C (122°F) with derating Altitude Up to 1000 m (3280 ft) without derating Standards & Approvals IEC, UL, CSA, CE; compliant with IEC 60947-4-2
Technical Specifications Parameter Specification Product Code PSTB1050-600-70 Series ABB PSTB Medium Voltage Soft Starters Rated Voltage 3300 V / 6000 V (switch-selectable) Rated Current 1050 A (continuous at 40°C) Starting Current Adjustable, typically 200% - 500% of motor Full Load Current (FLC) Motor Power Range Approx. 5500 - 8000 kW (dependent on voltage, motor PF & efficiency) Control Supply Voltage 110-120V AC or 220-240V AC, 50/60 Hz (configurable) Starting Time Adjustable from 10 to 120 seconds (or more for very high inertia loads) Stopping Time Adjustable soft-stop (optional) Cooling Method Forced air cooling with high-capacity fans; may require external ducting. Enclosure IP00 / Open Type (intended for installation in a robust, contractor-suppiled floor-standing cubicle) Ambient Temperature 0°C to +40°C (32°F to 104°F) for full rating; derating up to +50°C (122°F) Altitude Up to 1000 m (3280 ft) without derating Standards & Approvals IEC, IEEE, UL, CSA, CE; compliant with IEC 60947-4-2, IEEE 519
Technical Specifications Parameter Specification Product Code PSE85-600-70 Series ABB PSE Electronic Motor Starters Rated Operational Current (Iₑ) 85 A (at 400V, 40°C ambient) Supply Voltage 3-phase, 380 - 690 V AC, 50/60 Hz Motor Power Range Approx. 45 - 55 kW (at 400V) Control Supply Voltage (Us) Selectable: 24 V AC/DC, 48-130 V AC, 110-130 V DC, or 200-240 V AC/DC Starting Method Voltage ramp with adjustable initial torque and ramp time. Starting Current Adjustable, typically up to 400% of motor Full Load Current (FLC). Stopping Method Coast stop (standard); programmable soft stop (optional). Motor Protection Class 10 electronic overload protection (I²t), phase loss/imbalance, jam/blocked rotor, underload, and PTC thermistor input for direct motor temperature monitoring. Enclosure IP00 (Open Type) for mounting inside a customer-supplied control cabinet. Ambient Temperature -25°C to +60°C (operating), with derating required above +40°C. Communication Via optional plug-in communication modules (e.g., PROFIBUS DP, Modbus RTU, DeviceNet). Standards & Approvals IEC/EN 60947-4-2, UL 508, CE, cULus listed.
Technical Specifications Parameter Specification Product Code PSTX250-600-70 Series ABB PSTX Medium Voltage Soft Starters Rated Voltage 3300 V / 6000 V (switch-selectable) Rated Current 250 A (continuous at 40°C) Starting Current Adjustable, typically 200% - 450% of motor FLC (Full Load Current) Motor Power Range Approx. 1400 - 1850 kW (dependent on voltage & motor characteristics) Control Supply Voltage 110-120V AC or 220-240V AC, 50/60 Hz (configurable) Starting Time Adjustable from 5 to 120 seconds Stopping Time Adjustable soft-stop (optional, 5 to 120 seconds) Cooling Method Forced air cooling (integrated fans) Enclosure IP00 / Open Type (for cabinet installation) Ambient Temperature 0°C to +40°C (32°F to 104°F) for full rating; up to +50°C (122°F) with derating Altitude Up to 1000 m (3280 ft) without derating Standards & Approvals IEC, UL, CSA, CE; compliant with IEC 60947-4-2
Technical Specifications Parameter Specification Product Code PSE60-600-70 Series ABB PSE Electronic Motor Starters Rated Operational Current (Iₑ) 60 A (at 400V, 40°C) Supply Voltage 3-phase, 380 - 690 V AC, 50/60 Hz Motor Power Range Approx. 30 - 37 kW (at 400V) Control Supply Voltage (Us) 24 V AC/DC, 48-130 V AC, 110-130 V DC, or 200-240 V AC/DC (selectable) Starting Method Voltage ramp with adjustable initial torque (kick start) and ramp time. Starting Current Adjustable, typically 200% - 400% of motor FLC. Stopping Method Coast stop (standard); Soft stop (optional, adjustable). Motor Protection Class 10 electronic overload, phase loss/imbalance, jam protection, underload, PTC thermistor input. Enclosure IP00 (Open Type) for panel mounting. Ambient Temperature -25°C to +60°C (operating), derating above +40°C. Communication Via optional plug-in modules (e.g., PROFIBUS DP, Modbus RTU). Standards & Approvals IEC/EN 60947-4-2, UL 508, CE, cULus.
Technical Specifications Parameter Specification Product Code PSE170-600-70 Series ABB PSE Electronic Motor Starters Rated Operational Current (Iₑ) 170 A (at 400V, 40°C) Rated Supply Voltage 3-phase, 380 - 690 V AC, 50/60 Hz Motor Power Range Approx. 90 - 110 kW (at 400V) Control Supply Voltage (Us) 24 V AC/DC, 48-130 V AC, 110-130 V DC, or 200-240 V AC/DC (selectable) Starting Method Voltage Ramp with adjustable initial torque and ramp time. Starting Current Adjustable, typically up to 400% of motor FLC (Full Load Current). Stopping Method Coast stop (default) or optional soft stop. Motor Protection Class 10 electronic overload protection, phase imbalance, jam/blocked rotor, underload, PTC thermistor input. Enclosure IP00 (Open Type) for mounting in a customer-supplied control cabinet. Ambient Temperature -25°C to +60°C (derating above +40°C) Communication Optional plug-in communication modules (e.g., PROFIBUS DP, Modbus RTU, DeviceNet). Standards IEC/EN 60947-4-2, UL 508, CE, cULus.
Technical Specifications Parameter Specification Product Code PSE210-600-70 Series ABB PSE Electronic Motor Starters Rated Operational Current (Iₑ) 210 A (at 400V, 40°C) Rated Supply Voltage 3-phase, 380 - 690 V AC, 50/60 Hz Motor Power Range Approx. 110 - 132 kW (at 400V) Control Supply Voltage (Us) 24 V AC/DC, 48-130 V AC, 110-130 V DC, or 200-240 V AC/DC (selectable) Starting Method Voltage Ramp with adjustable initial torque and ramp time. Starting Current Adjustable, typically up to 400% of motor FLC (Full Load Current). Stopping Method Coast stop (default) or optional soft stop. Motor Protection Class 10 electronic overload protection, phase imbalance, jam/blocked rotor, underload, PTC thermistor input. Enclosure IP00 (Open Type) for mounting in a customer-supplied control cabinet. Ambient Temperature -25°C to +60°C (derating above +40°C) Communication Optional plug-in communication modules (e.g., PROFIBUS DP, Modbus RTU, DeviceNet). Standards IEC/EN 60947-4-2, UL 508, CE, cULus.