Parameter Specification Part Number 2CDS200912R0001 ABB Reference S2C‑H6R Function Auxiliary Contact / Signalling Switch Contact Configuration SPDT (1 Change-over Contact) Rated Current ~10 A (typical auxiliary duty) Rated Operational Voltage Compatible with AC/DC control circuits (e.g., 230 V AC common rating) Mounting Position Right-side mounting on compatible modular devices Suitable for Device Series MCB S 200 series, SN 201 series, RCCB F 200 series, RCBO DS201/DS202C and DS 200 series Standards Compliance IEC/EN 60947‑5‑1; UL 1077 Dimensions (approx.) Width 8.8 mm; Height 85 mm; Depth 69 mm Weight (approx.) 0.043 kg RoHS Status Compliant

Technical Specifications Parameter Specification Part Number 1SDA051002R1 Product Type Moulded Case Circuit Breaker (MCCB) Series / Range Tmax T2S Pole Configuration 3‑pole (3P) Rated Current (In) 100 A Trip Unit Thermal‑magnetic (TMD), adjustable thermal setting 100‑1000 A Rated Insulation Voltage (Ui) 800 V Rated Operational Voltage (Ue) 690 V AC / 500 V DC Impulse Withstand Voltage (Uimp) 8 kV Rated Ultimate Short‑Circuit Breaking Capacity (Icu) up to 50 kA (varies by voltage) Rated Service Short‑Circuit Breaking Capacity (Ics) up to 85 kA (at lower AC voltages) Connection Type Fixed (front) terminals Version F Standards Compliance IEC 60947 Mechanical Durability ~25 000 operations Electrical Durability ~8 000 operations Weight ~1.1 kg Dimensions (W x H x D) ~90 mm x 130 mm x 70 mm

Technical Parameters Parameter Specification Product type Molded Case Circuit Breaker (MCCB) Product series ABB SACE Tmax XT3N Poles 3 poles Terminal type Fixed front terminals (FF) Trip unit type TMD (Thermal‑magnetic) Adjustable instantaneous (short‑circuit) setting 250 A to 2500 A Rated uninterrupted (frame) current 250 A Rated operational voltage (Ue) Up to 690 V AC / 500 V DC Rated insulation voltage (Ui) 800 V AC Rated impulse withstand voltage (Uimp) 8 kV Rated service short‑circuit breaking capacity (Ics) e.g., 37.5 kA @ 230 V AC, 27 kA @ 380–415 V AC (typical IEC values) Rated ultimate short‑circuit breaking capacity (Icu) Higher values depending on system voltage and configuration Protection functions Overload protection, short‑circuit protection Standards compliance IEC 60947‑2 (low‑voltage circuit breakers) Mechanical durability ~25,000 operations Electrical durability ~8,000 operations at rated load Mounting Fixed panel installation Typical applications Industrial and commercial power distribution, feeder protection, switchboards

Technical Parameters Parameter Specification Product type Electromechanical magnetic contactor Product series ABB A series Poles (main contacts) 3 poles (3 NO) Coil/control voltage 110 V AC (50 Hz) / 110–120 V AC (60 Hz) Rated operational voltage (main) Up to 690 V AC Conventional free‑air thermal current (Ith) 28 A at 40 °C Rated operational current AC‑1 (Ie) ~27 A at 690 V Rated operational current AC‑3 (Ie) ~12 A at 415–500 V; ~9 A at 690 V Rated operational power AC‑3 ~3 kW at 230–240 V; ~5.5 kW at 380–415 V; ~7.5 kW at 500–690 V Rated operational current AC‑15 Up to 6 A at 24–127 V AC; 4 A at 220–240 V; 2 A at 500–690 V Making/breaking capacity 10 × Ie AC‑3 making; AC‑15 10 × Ie breaking Rated frequency limits 25–400 Hz Operating temperature –40 °C to +55 °C Coil power consumption ~74–80 VA pull‑in, ~8 VA holding Terminal type Screw terminals Auxiliary contacts Typically 1 NO auxiliary contact Mounting Panel / DIN rail (with adapter) Protection degree IP20 Standards IEC 60947‑4‑1 / IEC 60947‑5‑1 compliant Typical applications Motor starters, control panels, automation systems

Technical Parameters (English) Parameter Specification Product type Molded Case Circuit Breaker (MCCB) Product family ABB S2N / SACE MCCB ABB Ordering Code 1SDA092547R1 Poles 4 poles (4P) Frame rating 160 A (S2N160 family typical) Trip unit type Thermal‑magnetic (adjustable) Current setting (overload) Typical adjustable range around R125 (e.g., 80 A–125 A) Rated operational current (In) 125 A setting (nominal value on listing) Rated operational voltage (Ue) Up to 690 V AC Rated insulation voltage (Ui) ~800 V AC Rated impulse withstand voltage (Uimp) 8 kV Breaking capacity Depends on exact C curve and variant (industrial MCCB level) Protection functions Overload & short‑circuit protection Terminal type Front fixed and front cable‑ready (FFC) Standards compliance IEC/EN 60947‑2 (typical for MCCBs) Mounting Fixed panel installation Typical applications Industrial / commercial power distribution and circuit protection

Technical Parameters Parameter / Requirement Typical Specification / ABB Compliance Standard Type IEC 60947‑4‑1 / EN 60947‑4‑1 Device Category Motor control and protection devices Scope Contactors, motor starters, thermal overload relays, manual starters Rated operational voltage (Ue) Up to 690 V AC / 500 V DC (depending on device) Rated insulation voltage (Ui) Up to 1000 V AC Rated current (Ie) Depends on device (e.g., MCCB, contactor, starter) Rated service short-circuit breaking capacity (Ics) Defined per device, e.g., MCCB 25–100 kA Protection functions Overload, short-circuit, phase-failure, motor stall Mechanical endurance Typically ≥25,000 operations for contactors, MCCBs Electrical endurance Typically ≥8,000–10,000 operations at rated load Operating temperature range -25 °C to +60 °C (typical) Mounting Panel, DIN rail, or chassis depending on device Environmental compliance IP20–IP65 (depending on enclosure and device type) Certification / Testing Type-tested according to IEC/EN 60947‑4‑1, CE marking, UL/CSA where applicable ABB Typical Products MS132/MS495 manual motor starters, T1/T2/Tmax MCCBs, XT/AX series contactors, AF/AX soft starters

Technical Parameters Parameter Specification Product type Manual motor starter / Motor protection breaker ABB Ordering Code 1SAM350000R1013 Model / Series MS132‑20 Rated operational current (Ie) 20 A Setting range (overload) 16–20 A Number of poles 3 poles Rated operational voltage 250–690 V AC Rated service short‑circuit breaking capacity (Ics) 100 kA @ 400 V AC Mechanical operation Thermo‑magnetic trip Trip class Class 10 Short‑circuit release setting (instantaneous) 300 A Rated motor power AC‑3 7.5 kW at 230/400 V AC Mounting DIN rail / panel mount Connection type Screw terminals Phase failure sensitive Yes Handle Rotary ON/OFF/TRIP, lockable Protection degree IP20 Ambient operating temperature Approx. ‑25 °C to +60 °C Standards IEC/EN 60947‑1/-2/-4‑1 Typical applications Motor start/stop and protection in industrial machinery and control panels

Technical Parameters Parameter Specification Product type Molded Case Circuit Breaker (MCCB) Product series ABB SACE Tmax XT2N ABB Ordering Code 1SDA067013R1 Poles 3 poles Terminal type Front fixed terminals (FF) Trip unit type TMD (Thermal‑magnetic) Current setting range 32–320 A (overload and short‑circuit) Frame rating 160 A Rated operational voltage (Ue) Up to 690 V AC / 500 V DC Rated insulation voltage (Ui) 1000 V AC Rated impulse withstand voltage (Uimp) 8 kV Rated service short‑circuit breaking capacity (Ics) 65 kA @ 220–240 V AC, 36 kA @ 380–440 V AC, 30 kA @ 500 V AC, 10 kA @ 690 V AC (typical IEC values) Rated ultimate short‑circuit breaking capacity (Icu) Same categories as Ics depending on voltage Overload release setting 22.4–32 A Undelayed short‑circuit release setting 320 A fixed Connection type Bolt connections, front fixed Compliant standards IEC 60947‑2 Mechanical durability ~25,000 operations Electrical durability ~8,000 operations Typical applications Industrial and commercial power distribution, feeder protection

Technical Parameters Parameter Specification Product type Electronic multifunction time relay Model / Type CT‑MBS.22S ABB Ordering Code 1SVR730010R3200 Supply voltage (control voltage) 24–240 V AC / 24–48 V DC Timing range 0.05 s to 300 h (10 adjustable time ranges) Timing functions Multiple timing modes for on‑delay, off‑delay, star‑delta change‑over, flasher, pulse former, ON/OFF, etc. Output contacts 2 change‑over (SPDT) Contact rating 250 V AC, ~4 A (typical) Contact form 2 C/O (SPDT) relay outputs Trigger input Volt‑free (floating) trigger input Display / Indication LED status indication Remote adjustment Remote potentiometer connection supported Terminals Screw terminals with double‑chamber cage connection Mounting DIN rail (35 mm TH rail) Enclosure protection IP20 / IP50 variants available Housing width 22.5 mm Height ~85.6 mm Depth ~103.7 mm Operating temperature –25 °C to +60 °C Storage temperature –40 °C to +85 °C Standards / Compliance EN/IEC 61812‑1, CE, UL, RoHS compliant Typical applications Timing control in automation, machine control, motor sequencing, delay functions

Technical Parameters Parameter Specification Product type Residual Current Circuit Breaker (RCCB) Product series ABB F200 / F204 AC ABB Ordering Code 2CSF204005R1800 Poles 4 poles (4P) Rated current (In) 80 A Rated operational voltage (Ue) 230 / 400 V AC Rated insulation voltage (Ui) 500 V Rated impulse withstand voltage (Uimp) 4 kV Rated residual current (IΔn) 30 mA Type of residual current Type AC (sensitive to AC sinusoidal leakage) Rated conditional short‑circuit current (Inc) 10 kA Rated service short‑circuit breaking capacity (Ics) 1 kA Standards compliance IEC 61008‑1 / IEC 61008‑2‑1 Leakage current sensing AC type leakage detection Mounting DIN rail Typical applications Earth leakage protection in distribution panels for residential, commercial, and light industrial installations

Technical Parameters Parameter Specification Product type Manual Motor Starter / Motor Protection Breaker Series / Model MS495‑63 ABB Ordering Code 1SAM550000R1007 Poles 3 Rated operational current (Ie) 63 A Overload release setting range 45–63 A Undelayed instantaneous short‑circuit release setting 819 A Rated operational voltage 230–690 V AC Rated service short‑circuit breaking capacity (Ics) 50 kA @ 400 V AC Thermal protection type Thermomagnetic Phase failure sensitive Yes Rated motor power (AC‑3, 400 V) 30 kW Connection type Screw terminals Control element Rotary handle (ON/OFF/TRIP) Handle features Lockable to prevent unauthorized changes Mounting Panel / DIN‑rail (TH35) Protection degree Housing IP20, Main terminals IP00 Insulation withstand / Impulse Typical 6 kV Ambient operating temperature ‑20 °C to +70 °C (compensated ‑20 °C to +60 °C) Ambient storage temperature ‑50 °C to +80 °C Mechanical durability ~50 000 cycles Electrical durability ~25 000 cycles Standards IEC/EN 60947‑1, 60947‑2, 60947‑4‑1, UL 508, CSA 22.2 No. 14 Typical applications Motor switching and protection, control panels, industrial installations

Technical Parameters Parameter Specification Product type Molded Case Circuit Breaker (MCCB) Product series ABB SACE Tmax XT2N Poles 3 poles Terminal type Front fixed terminals (FF) Trip unit type TMG (thermal‑magnetic) Adjustable current range 16 A to 160 A Frame rating 160 A Rated operational voltage (Ue) Up to 690 V AC / 500 V DC Rated insulation voltage (Ui) 1000 V AC Rated impulse withstand voltage (Uimp) 8 kV Rated service short‑circuit breaking capacity (Ics) 65 kA @ 220–240 V AC; 36 kA @ 380–415 V AC; 30 kA @ 500 V AC; 10 kA @ 690 V AC (typical IEC values) Indctl Protection functions Overload and short‑circuit protection Standards compliance IEC 60947‑2 Mechanical durability ~25,000 operations Electrical durability ~8,000 operations at rated load Mounting Fixed panel installation Typical applications Industrial/commercial power distribution, feeder protection, control panels