Technical Parameters General & Contact Configuration Product Type: Electromechanical contactor Series: ASL16 Number of Main Poles: 3 (three‑phase) Main Contact Configuration: 3 Normally Open (3 NO) Built‑In Auxiliary Contact: 1 Normally Open (1 NO) Control Circuit Type: DC coil (polarity sensitive) Electrical Ratings Rated Operational Voltage (Main Circuit): up to 690 V AC Rated Operational Voltage (Control Coil): DC (e.g., 220 V DC) Rated Operational Current (AC‑1): 30 A @ 690 V AC at 40 °C ambient 26 A @ 690 V AC at 70 °C ambient Rated Operational Current (AC‑3 – Motor Control): 18 A @ 220–415 V AC 15 A @ 500 V AC 10.5 A @ 690 V AC Coil & Control Coil Type: DC magnet coil Control Voltage: Specified DC voltage variant (220 V DC typical for “88” suffix) Coil Polarity: Polarity must be respected for DC operation Insulation & Withstand Rated Insulation Voltage (Ui): 690 V AC Rated Impulse Withstand Voltage (Uimp): 6 kV Conventional Free‑Air Thermal Current (Ith): 35 A @ 40 °C Mechanical & Mounting Terminal Type: Screw terminals Mounting: DIN‑rail or panel mount compatible Mechanical Durability: High cycle life typical for ASL contactors Dimensions: 45 mm (W) × 77 mm (D) × 86 mm (H) Net Weight: ~0.30 kg Environmental Operating Ambient Temperature: −25 °C to +60 °C (with thermal overload) Without overload: −40 °C to +70 °C Pollution Degree: 3 Protection: IP20 (installed inside panel)
Technical Parameters Electrical Type: Illuminated buzzer / acoustic indicator Rated Voltage: 24 V AC/DC Voltage Type: AC and DC compatible Rated Current: approx. 53 mA @ 24 V Sound Output: Pulsating tone Sound Level: approx. 80 dB Light Output: Red illuminated LED with pulsating indication Mechanical & Mounting Mounting Hole Diameter: ~22 mm panel cut‑out (standard pilot device size) Mounting Style: Panel mount (screw clamp connection) Terminal Type: Screw clamp terminals Housing Color: Black body with red illuminated lens Approx. Dimensions: ~30 mm (W) × ~30 mm (H) × ~55 mm (D) Net Weight: ~0.021 kg Environmental & Protection Operating Ambient Temperature: –25 °C to +70 °C Storage Temperature: –40 °C to +85 °C Protection Rating (Front): IP66 / IP67 / IP69K (dust tight and high‑pressure washdown rated on the front) Terminals Protection: IP20 Pollution Degree: 3 NEMA Ratings: Type 1, 3R, 4, 4X, 12, 13 environments
Technical Parameters Electrical Device Type: Illuminated buzzer / sound‑and‑light indicator Rated Voltage: ~230 V AC (AC mains) compatible (also usable with 230 V DC in some implementations) Rated Current: ~70 mA Frequency: 50 / 60 Hz Signal Type: Pulsating audible tone combined with a pulsating red light Acoustic & Visual Output Sound Level: approx. 80 dB (audible alert level suitable for panel alarms) Light Indicator: Red LED or lamp illumination Mechanical & Installation Mounting Style: Panel mount (standard 22 mm cut‑out diameter) Body Material: Durable plastic housing Terminal Type: Screw terminals Approximate Dimensions: ~30 mm (W) × ~30 mm (H) × ~55 mm (D) Weight: ~0.021 kg Color: Red visual indicator Environmental Operating Ambient Temperature: approx. −25 °C to +70 °C Protection Rating: Front: High ingress protection (dust/water resistance depending on installation) Terminals: IP20
Technical Parameters Electrical Ratings Rated Current (In): 4 A Number of Poles: 2P (two poles) Tripping Curve: C‑curve (moderate inrush tolerance) Rated Operational Voltage (Ue): Up to 400 V AC (IEC 60898‑1) Up to 440 V AC (IEC 60947‑2) Rated Insulation Voltage (Ui): 440 V Rated Frequency: 50 / 60 Hz Rated Short-Circuit Breaking Capacity (Icn): 10 kA at 230/400 V AC Rated Ultimate Breaking Capacity (Icu): up to 15 kA Current Limiting Class: 3 Overvoltage Category: III Rated Impulse Withstand Voltage (Uimp): 4 kV DC Interrupting Capability: up to ~125 V DC Mechanical & Installation Mounting: Standard DIN‑rail (35 mm) Terminal Type: Screw terminals Tightening Torque: Approx. 2 N·m Mechanical Endurance: ~20,000 operations Electrical Endurance: ~20,000 AC cycles Contact Position Indication: ON (red) / OFF (green) Housing Material: High-quality insulating material (light grey) Environmental Ambient Operating Temperature: −25 °C to +55 °C Pollution Degree: 3 Protection Rating: IP20 (installed in enclosure) Mounting Position: Any
Technical Parameters Electrical Ratings Rated Current (In): 25 A Number of Poles: 2P (two poles) Tripping Curve: B‑curve (for low inrush loads) Rated Operational Voltage (Ue): Up to 400 V AC (IEC 60898‑1) Up to 440 V AC (IEC 60947‑2) Rated Insulation Voltage (Ui): 440 V Rated Frequency: 50 / 60 Hz Rated Short‑Circuit Breaking Capacity (Icn): 10 kA at 230/400 V AC Rated Ultimate Breaking Capacity (Icu): up to 15 kA Current Limiting Class: 3 Overvoltage Category: III Rated Impulse Withstand Voltage (Uimp): 4 kV Operational Voltage Range: AC/DC 12 V to AC 440 V (typical) DC Interrupting Capability: Up to 125 V DC (depending on certification) Mechanical & Installation Mounting: Standard DIN‑rail (35 mm) Terminal Type: Screw terminals Tightening Torque: Approx. 2 N·m Mechanical Endurance: ~20,000 operations Electrical Endurance: ~20,000 AC cycles Contact Position Indication: ON (red) / OFF (green) Housing Material: High‑quality insulation (light grey) Environmental Ambient Operating Temperature: approx. −25 °C to +55 °C Pollution Degree: 3 Protection Rating: IP20 (installed within enclosure) Mounting Position: Any
Technical Parameters Electrical Ratings Number of Main Poles: 3 (three‑phase switching) Auxiliary Contacts: 1 NO + 1 NC for control and feedback Control Coil Voltage Range: 100–250 V AC/DC (wide‑range coil) Rated Operational Voltage (Main Circuit): up to 690 V AC Rated Operational Frequency: 50 / 60 Hz Conventional Free‑Air Thermal Current (Ith): up to 200 A at 40 °C (AC‑1 rating) Rated Operational Current (AC‑1): ~200 A @ 690 V AC (40 °C) ~160 A @ 690 V AC (70 °C) Rated Operational Current (AC‑3 – motor control): ~140 A @ 415 V AC ~130 A @ 500 V AC ~80 A @ 690 V AC Rated Motor Power (AC‑3): ~37 kW @ 220–240 V AC ~75 kW @ 380–415 V AC ~90 kW @ 440–500 V AC ~75 kW @ 690 V AC Rated Impulse Withstand Voltage (Uimp): 8 kV Rated Insulation Voltage (Ui): 600/690 V AC Coil & Control Coil Type: Electronically controlled coil with built‑in surge suppression Wide Control Voltage Handling: Single coil covers wide control voltage range without needing coil changes Voltage Dip Tolerance: Designed to withstand short voltage drops and sags Mechanical & Endurance Mechanical Durability: ~5,000,000 cycles Maximum Switching Frequency: AC‑1: ~300 cycles/hour AC‑3: ~300 cycles/hour Mounting: DIN‑rail or panel mount compatible with accessories Terminal Type: Screw terminals for main and auxiliary connections Dimensions (approx.): 150 mm (H) × 90 mm (W) × 126 mm (D) Operating Altitude: Up to ~3000 m without derating Environmental Operating Temperature: approx. ‑25 °C to +50 °C
Technical Parameters Electrical Ratings Product Type: Fuse Switch Disconnector with EFM Series: EasyLine XLP Number of Poles: 3 (three‑pole) Rated Current (Iu): 160 A – continuous current rating for the main circuit Rated Operational Voltage (Ue): up to 1000 V AC Rated Frequency: 50 / 60 Hz Rated Insulation Voltage (Ui): Designed for IEC rated systems Rated Impulse Withstand Voltage (Uimp): 8 kV Rated Operational Current (AC‑21B / AC‑22B / AC‑23B): AC‑21B (690 V): ~125 A AC‑22B (500 V): ~160 A AC‑23B (400 V): ~125 A Conditional Short‑Circuit Current (Iq / Icn): 50 kA RMS Fuse Compatibility: NH000, NH00 fuse bases Functional Features Electronic Fuse Monitoring (EFM): Integrated EFM improves safety by indicating fuse status and enabling fault detection Bridge Clamps: Includes 6 bridge clamps for easy and secure cable termination Switch Function: Manual load isolation in combination with fuse protection Safety Features: Designed for safe front operation and clear isolation indication Mechanical & Installation Mounting: Baseplate mount with front‑accessible control element Terminal Type: Cable clamp terminals for main circuit connections Handle Position: Front‑located operating element Suitable Mounting Systems: Can be installed on busbar structures or distribution frames Degree of Protection: IP30 at front Main Circuit Connection: Screw/clamp type cables Environmental & Physical Operating Range: Industrial ambient conditions Approx. Weight: ~0.63–0.68 kg Dimensions: Typical panel/fuse switch disconnector footprint with compact design Pole Configuration: 3‑pole for three‑phase systems
Technical Parameters General Product Type: Industrial control switch Series: ABB E218 Mounting: DIN‑rail mounting (standard 35 mm rail) Module Width: Approx. 1 modular unit (~18 mm) Degree of Protection: IP20 (installed in enclosure) Color: Gray operator and housing Contact Configuration Number of Poles / Contacts: 4 2 Normally Open (NO) 2 Normally Closed (NC) Contact Type: Snap‑action changeover contacts suitable for control circuits Electrical Ratings Rated Current: 16 A per contact set (AC) Rated Operational Voltage: 250 V AC Frequency: 50 / 60 Hz Short‑Circuit Breaking Capacity (Icw): 3 kA Contact Material: Suitable for standard control loads Mechanical & Installation Terminal Type: Screw terminals for secure conductor connection Connecting Capacity: Solid: ~1…6 mm² Flexible: ~0.75–2.5 mm² Tightening Torque: ~1.2–1.5 N·m Dimensions (approx.): Width: 18 mm Depth: 68 mm Height: 85 mm Weight: ~0.08–0.09 kg
Technical Parameters Electrical Ratings Rated Current (In): 2 A Number of Poles: 2P (two poles) Tripping Characteristic: C‑curve (suitable for moderate inrush loads) Rated Operational Voltage (Ue): Up to 400 V AC (IEC 60898‑1) Up to 440 V AC (IEC 60947‑2) Rated Insulation Voltage (Ui): 440 V Rated Frequency: 50 / 60 Hz Rated Short‑Circuit Breaking Capacity (Icn): 10 kA at 230/400 V AC Rated Ultimate Short‑Circuit Breaking Capacity (Icu): up to 15 kA Current Limiting Class: 3 Overvoltage Category: III Rated Impulse Withstand Voltage (Uimp): 4 kV Operational Voltage Range: 12 V AC/DC to 440 V AC DC Interrupting Capability: Up to approx. 125 V DC Mechanical & Mounting Mounting: Standard DIN‑rail (35 mm) Terminal Type: Screw terminals Tightening Torque: Approx. 2 N·m Mechanical Endurance: ~20,000 operations Electrical Endurance: ~20,000 AC cycles Housing Material: High‑quality insulating material (light grey) Contact Position Indication: Red (ON) / Green (OFF) indicators Environmental Ambient Operating Temperature: approx. ‑25 °C to +55 °C Pollution Degree: 3 Protection Rating: IP20 (when mounted in panel/enclosure) Mounting Position: Any
Technical Parameters Electrical Ratings Device Type: Residual Current Circuit Breaker with Overcurrent Protection (RCBO) Number of Poles: 1 P + N (phase + neutral) Rated Current (In): 20 A Tripping Characteristic: C‑curve (medium inrush tolerance) Rated Residual Current (IΔn): 30 mA (earth leakage protection) Type of Residual Current: Type A (detects AC and pulsating DC leakage) Rated Operational Voltage: ~230/240 V AC, 50 / 60 Hz Rated Insulation Voltage (Ui): ~500 V AC Rated Impulse Withstand Voltage (Uimp): ~4 kV Rated Short‑Circuit Breaking Capacity: 6 kA typical ultimate breaking capacity Service breaking capacity at rated conditions Energy Limiting Class: Class 3 Current Limitation: Yes (internal limitation per IEC standards) Protection Functions Overload Protection: Thermal‑magnetic trip Short‑Circuit Protection: Magnetic trip Residual Current Protection: Trips at ≥ 30 mA leakage Protection Against Direct and Indirect Contact: Provided by combined RCBO action Mechanical & Mounting Mounting: Standard DIN‑rail (35 mm) Terminal Type: Cage or screw terminals for line, load, and neutral Neutral Facility: Firm neutral connection with switched/unswitched variants depending on version Contact Position Indication: ON/OFF indication on the toggle Number of Modular Widths: 2 modules wide (compact footprint) Environmental & Durability Pollution Degree: Typical industrial/class 3 Mechanical Endurance: ~20,000 operations Electrical Endurance: ~10,000 operating cycles Operating Temperature: ~‑25 °C to +55 °C Storage Temperature: wider industrial range
Technical Parameters General & Electrical Ratings Product Type: Electromechanical contactor (4‑pole) Main Contact Configuration: 4 Normally Open (4 NO) Control Coil Voltage: 100–250 V AC/DC (wide range control) Rated Operational Current AC‑1 (Ie): ~45 A @ 690 V AC (40 °C) ~40 A @ 690 V AC (60 °C) ~32 A @ 690 V AC (70 °C) Rated Operational Current AC‑3 (Ie): (motor control) ~23.2 A @ 220/230/240 V AC ~22 A @ 380/400 V AC ~21.2 A @ 415 V AC ~20 A @ 440 V AC ~17.6 A @ 500 V AC ~10.5 A @ 690 V AC Rated Insulation Voltage (Ui): 690 V Rated Impulse Withstand Voltage (Uimp): 6 kV Rated Frequency: 50 / 60 Hz Application Loads: Motors, non‑inductive and slightly inductive loads Performance & Endurance Conventional Free‑Air Thermal Current (Ith): ~55 A @ 40 °C Maximum Electrical Switching Frequency: ~600 cycles/hour (AC‑1) Maximum Mechanical Switching Frequency: ~3600 cycles/hour Operate/Release Times: Typical operate/release milliseconds (fast switching) Mechanical & Connection Number of Poles: 4 Terminal Type: Screw terminals for main and control connections Mounting: Panel or DIN‑rail with appropriate accessories Degree of Protection: IP20 (terminals and housing) Dimensions (approx.): 45 mm width × 101 mm depth × 86 mm height Approx. Weight: ~0.36 kg Operating Ambient Temperature: approx. –40 °C to +70 °C Permissible Altitude: up to 3000 m without derating Typical Ratings & Capabilities Rated Motor Loads (approx): 5.5 kW @ 220–240 V AC 11 kW @ 380–440 V AC 11 kW @ 500 V AC 9 kW @ 690 V AC Horsepower Ratings: 7½ hp @ 220–240 V AC (3‑phase) 15 hp @ 440–480 V AC (3‑phase) 20 hp @ 550–600 V AC (3‑phase) 2 hp @ 120 V AC (1‑phase) 3 hp @ 240 V AC (1‑phase)
Technical Parameters Electrical Ratings Contact Configuration: 3 poles, 3 normally open (3NO) Control Coil Voltage (Uc): 100–250 V AC/DC, 50/60 Hz Rated Operational Current (AC‑1): up to 105 A @ 690 V Rated Operational Current (AC‑3 Motor): ~65 A @ 220–415 V AC Rated Operational Power (AC‑3): 18.5 kW @ 230 V AC 30–37 kW @ 380–690 V AC Insulation Voltage (Ui): 600/690 V AC Rated Impulse Withstand Voltage (Uimp): 6 kV Frequency: 50/60 Hz Horsepower Ratings: Single-phase: 5 hp @ 120 V, 15 hp @ 240 V Three-phase: 25 hp @ 240 V, 50 hp @ 480 V, 60 hp @ 600 V Mechanical & Installation Mounting: DIN‑rail or panel mount Terminal Type: Screw terminals Operating Temperature Range: −60 °C to +80 °C Enclosure Protection: IP10 / IP20 depending on installation Operating Cycles: ~10,000,000 cycles Dimensions: 125.5 mm (H) × 55 mm (W) × 111 mm (D) Environmental & Operational Altitude: Up to ~3000 m without derating Surge Protection: Built‑in coil surge suppression for reliable operation