Industrial Controller
All product are in stock,guaranteed delivery within 3-7 days.
Infinite Innovation, the Future of Industrial Control Systems
Infinite Innovation, the Future of Industrial Control Systems
PRODUCT HOME>>PRODUCT
PRODUCT

PRODUCT

PICTURE

BRAND

DESCRIBE

STOCK

DOWNLOAD

Parameter Specification Device Type Rotary Isolator Switch / Disconnector (Load Break Switch) Product Series MJ / MJS Series Rated Operational Current (Ie) 60 A (at AC-22A / AC-23A duty) Number of Poles 4 Poles (3P + N) (Based on common "B" variant coding. Other variants exist, e.g., "A" for 3P, "C" for 2P). Must be confirmed on the device or datasheet. Rated Insulation Voltage (Ui) 690 V Rated Operational Voltage (Ue) 400 V AC / 500 V AC Utilization Category AC-22A (Switching of mixed resistive and inductive loads). AC-23A (Switching of motor loads or other highly inductive loads). Rated Making & Breaking Capacity Typically 10 x Ie (600 A) for AC-23A at 400V. Short-Time Withstand Current (Icw) Typically 10 kA for 1 second (ensures it can withstand fault currents without damage). Mechanical Durability ≥ 10,000 operations Electrical Durability ≥ 5,000 operations (at rated current) Control Method Manual rotary operation via handle. Handle is often detachable and can be padlocked in the OFF position (up to 3 padlocks). Mounting Mounts directly onto a panel or enclosure door via a mounting kit. The switch body is mounted behind the panel. Terminal Type Screw clamp terminals. Terminal Connection Capacity Typically up to 35 mm² (for 60A model). Protection Degree Switch body: IP00 (must be installed inside an enclosure). With handle mounted on door: Typically achieves IP54 or higher for the front. Ambient Temperature (Operation) -25°C to +60°C Standards Compliance IEC/EN 60947-1, IEC/EN 60947-3

Parameter Specification / Typical Value Device Type Protective / Measuring Current Transformer (CT) Primary Rated Current (Ipr) Variable. This is a core parameter determined by the application (e.g., 100A, 200A, 400A, 800A, etc.). The model "MT-105B" defines the mechanical and electrical design, while the primary current is specified upon ordering. Secondary Rated Current (Isr) Standardized: Typically 1 A or 5 A (This is another key ordering specification). Rated Burden 5 kΩ (at the specified secondary current and frequency). This is the impedance of the secondary circuit (including wires and relay/meter impedance) for which the accuracy class is guaranteed. Accuracy Class Typically 5P or 10P for protection, or 0.5, 0.5S, 1 for measurement. This is a critical ordering parameter. Example: "5P10" where '5' is the composite error in %, 'P' is for protection, and '10' is the accuracy limit factor (ALF). Accuracy Limit Factor (ALF) For protection classes (e.g., 10, 15, 20). Defines the multiple of rated current up to which the CT maintains its specified accuracy during faults. Rated Frequency 50 Hz or 60 Hz (as specified). Rated Insulation Level / Voltage Medium Voltage Level, e.g., 12 kV, 24 kV, or 36 kV. This is a primary safety specification and must match the system voltage. Short-Time Thermal Current (Ith) Specified in kA for a short duration (e.g., 1s or 3s). Indicates thermal withstand capability during a short-circuit. Dynamic Current (Idyn) Specified in kA peak. Indicates the mechanical withstand capability against electromagnetic forces during the first peak of a short-circuit current. Core Type / Quantity Often has multiple independent cores (e.g., 2 cores: one for protection class '5P', one for measurement class '0.5S'). Mounting Typically designed for flange mounting or busbar mounting inside metal-enclosed switchgear. Standards Compliance IEC 61869-1 & -2 (or the older IEC 60044-1), and other relevant national standards.

Parameter Specification Product Line / Series System Pro M compact S200 (S200M Series - Moulded Case) Device Type Miniature Circuit Breaker (MCB) Poles 2P (Two Poles) Rated Current (Iₙ) 8 A Rated Voltage (Uₙ) 230/400 V AC Rated Frequency 50/60 Hz Breaking Capacity (Icn) 10 kA (at 230/400V AC) - This is the defining feature of the S200M series. Tripping Characteristic C Curve (Instantaneous magnetic trip operates between 5 to 10 times Iₙ, i.e., between 40A and 80A). Ideal for circuits with moderate inrush currents (e.g., lighting, transformers, small motors). Mechanical Endurance ≥ 20,000 operations Electrical Endurance ≥ 10,000 operations (at Iₙ) Mounting 35 mm symmetrical DIN rail (EN 60715) Width 36 mm (2 standard modules, each 18mm) Terminal Torque 1.5 - 2.0 Nm (for rated cross-section conductors) Connection Capacity Rigid Cable: Up to 25 mm² Flexible Cable: Up to 16 mm² (with ferrule recommended) Standards Compliance IEC/EN 60898-1, IEC/EN 60947-2 Ambient Temperature (Operation) -25°C to +55°C Protection Degree (Terminals) IP20 Reference Standard for Wiring IEC/EN 60999

Parameter Specification Product Line / Series System Pro M compact S200 (Legacy: S200 Series) Device Type Miniature Circuit Breaker (MCB) Poles 2P (Two Poles) Rated Current (Iₙ) 40 A Rated Voltage (Uₙ) 230/400 V AC Rated Frequency 50/60 Hz Breaking Capacity (Icn) 6 kA (at 230/400V AC) - This is a standard value for the base S200 series. Higher capacity versions (e.g., S202S-C40 with 10kA) are available. Tripping Characteristic C Curve (Instantaneous magnetic trip operates between 5 to 10 times Iₙ, i.e., between 200A and 400A). Suitable for circuits with moderate inrush currents like lighting, household sockets, and small motors. Mechanical Endurance ≥ 20,000 operations Electrical Endurance ≥ 10,000 operations (at Iₙ) Mounting 35 mm symmetrical DIN rail (EN 60715) Width 36 mm (2 standard modules, each 18mm) Terminal Torque 2.5 - 3.0 Nm (for rated cross-section conductors) Connection Capacity Rigid Cable: 1x 35 mm² / 2x 25 mm² Flexible Cable: 1x 25 mm² (with ferrule) / 1x 35 mm² (with ferrule) Standards Compliance IEC/EN 60898-1, IEC/EN 60947-2 Ambient Temperature (Operation) -25°C to +55°C Storage Temperature -40°C to +70°C Reference Standard for Wiring IEC/EN 60999

Parameter Specification Product Line / Series System M (M200 S-series) - MSxxx compact series Device Type Miniature Circuit Breaker (MCB) - 1P+N (Single Pole + Neutral) Protected Poles 1 (Phase/Live only) Switched Poles 2 (Phase and Neutral) Rated Current (Iₙ) 2.5 A Rated Voltage (Uₙ) 230/400 V AC (Phase to Neutral / Phase to Phase) Rated Frequency 50/60 Hz Breaking Capacity (Icn) 10 kA (at 230/400V AC) Tripping Characteristic C Curve (Instantaneous trip between 5x and 10x Iₙ). Suitable for applications with moderate inrush currents. For a 2.5A device, this is often used for small transformer-fed circuits (e.g., doorbells, control power) or specific lighting loads. Mechanical Endurance ≥ 20,000 operations Electrical Endurance ≥ 10,000 operations (at Iₙ) Mounting 35 mm symmetrical DIN rail (EN 60715) Width 18 mm (This is a key advantage: it occupies the space of a single standard module, despite being a 1P+N device). Terminal Torque 1.5 Nm (for rated cross-section conductors) Connection Capacity Typically up to 16 mm² (Confirm with official datasheet) Standards Compliance IEC/EN 60898-1 Ambient Temperature (Operation) -25°C to +55°C

Parameter Specification Product Line / Series System M (M200 S-series) - MSxxx sub-series Device Type Miniature Circuit Breaker (MCB) Poles 1P (Single Pole) Rated Current (Iₙ) 10.0 A Rated Voltage (Uₙ) 230/400 V AC Rated Frequency 50/60 Hz Breaking Capacity (Icn) 10 kA (at 230/400V AC) Tripping Characteristic B Curve (Instantaneous trip between 3x and 5x Iₙ). Ideal for circuits with low inrush currents, such as lighting and socket outlets for resistive loads (e.g., heaters, lamps). Mechanical Endurance ≥ 20,000 operations Electrical Endurance ≥ 10,000 operations (at Iₙ) Mounting 35 mm symmetrical DIN rail (EN 60715) Width Approximately 17.5 mm (This is a key feature; it is narrower than a standard 18mm module, but exact specs may vary slightly. Confirm with ABB's official MSxxx series datasheet for precise dimensions). Terminal Torque 1.5 Nm (for rated cross-section conductors) Connection Capacity (Rigid/Flexible) Typically up to 16 mm² (Please verify with the specific MSxxx series datasheet for the 10A model) Standards Compliance IEC/EN 60898-1 Ambient Temperature (Operation) -25°C to +55°C

Parameter Specification Device Type Residual Current Circuit Breaker (RCCB) / RCD Product Series DDA200 Series Number of Poles 2 Poles (2P) - Protects both Live and Neutral Rated Current (Iₙ) 25 A Rated Residual Operating Current (IΔn) 30 mA (0.03 A) RCCB Type Type AC - For sinusoidal alternating residual currents only. Rated Voltage (Uₙ) 230 V AC Rated Frequency 50/60 Hz Rated Conditional Short-Circuit Current (Icn) 25 kA (Complies with IEC/EN 61008) Tripping Time ≤ 0.3 seconds (for IΔn = 30 mA, at 0°C to +40°C) Trip Characteristic Instantaneous Mounting 35 mm symmetrical DIN rail (EN 60715) Width 36 mm (2 modules) Electrical Durability ≥ 4,000 operating cycles Mechanical Durability ≥ 10,000 operating cycles Terminal Torque 2.0 Nm Suitable Cross-Section (Rigid/Flexible) Up to 25 mm² Ambient Temperature (Operation) -25°C to +55°C Standards Compliance IEC/EN 61008-1, IEC/EN 61008-2-1 Protection Class IP20 (for enclosure)

Technical Data: Parameter Specification Product Line / Series System E (S200 S-series) Poles 1P (Single Pole) Rated Current (Iₙ) 25 A Rated Voltage (Uₙ) 230/400 V AC Rated Frequency 50/60 Hz Breaking Capacity (Icn) 6 kA (at 230/400V AC) Tripping Characteristic C Curve (Instantaneous trip between 5x and 10x Iₙ). Suitable for applications with moderate inrush currents, such as lighting, sockets, and small motors. Mechanical Endurance ≥ 20,000 operations Electrical Endurance ≥ 10,000 operations (at Iₙ) Mounting 35 mm symmetrical DIN rail (EN 60715) Width (1 Pole) 18 mm (1 module) Terminal Torque 2.0 - 2.5 Nm (for rated cross-section conductors) Connection Capacity Rigid Cable: 1x 25 mm² / 2x 16 mm² Flexible Cable: 1x 16 mm² (with ferrule) / 1x 25 mm² (with ferrule) Standards Compliance IEC/EN 60898-1, IEC/EN 60947-2 Ambient Temperature -25°C to +55°C (Operation) Storage Temperature -40°C to +70°C

Technical Parameters Electrical Ratings Rated Control Supply Voltage (Ur): 220–250 V AC / 220–250 V DC (AC and DC compatible) Current Type: Both AC and DC control input accepted Suitable Product Family: Accessories for Tmax T6 series molded‑case circuit breakers Standards: Designed and tested to relevant IEC standards for motor operators Mechanical / Functional Type of Mechanism: Stored‑energy motor operator — charges an internal spring or energy store and then actuates the breaker Operation: Enables remote electrical opening and closing of Tmax T6 breakers Configuration Type: Loose or configurable accessory (can be integrated into breaker assembly) Compatibility Compatible With: ABB Tmax T6 frame MCCBs Product Main Type: Accessory (motor operator) Often used for automated switching, interlocking systems, and remote control applications Physical / Mechanical Approx. Weight: ~3.3–3.4 kg Product Dimensions: Typical accessory module size (compact motor‑drive unit) Mounting: Designed to mount on or integrate with compatible Tmax‑series breakers Environmental Designed For: Industrial distribution board and switchgear environments Operating Conditions: Suitable for typical electrical panel ambient conditions and industrial usage

Technical Parameters General Product Category: Emergency Stop / Safety Push Button Series: SMILE 11 EAR TINA Actuator Type: Mushroom push button, twist release Housing Color: Red with yellow background (standard emergency stop color) Mounting Type: Panel mount Connector: 1 × M12‑5 male connector for quick installation Status Indication: Integrated LED for emergency status feedback Electrical Supply / Control Voltage: 24 V DC Current Consumption: Approx. 0.047–0.057 A @ 24 V DC Outputs / Interface: DYNlink connection through M12‑5 male connector Contact Configuration: Designed for safety circuit integration (typically safety contacts in system controller — detailed contact info depends on system wiring) Protection & Standards Degree of Protection: IP65 (dust tight and protected against water jets) Safety Performance Level: Designed for use in safety circuits with high Performance Level (PL e capability) Operating Temperature Range: approx. industrial ambient (typical panel environment) Mechanical & Dimensions Twist Release: Yes (reset requires twist after actuation) Panel Cut‑out: Standard industrial emergency stop panel cut‑out (~30–32 mm) Approx. Width: ~40 mm Approx. Height: ~84–97 mm Approx. Depth: ~52–57 mm Net Weight: ~0.076 kg Features & Functions Safety Use: Designed for emergency stop function in machine safety systems Visual Feedback: Illuminated LED indicates contact status or emergency condition Connector Ease: M12‑5 male connector simplifies networked safety wiring Reversed Button Attachment: Button fitted in reversed orientation helpful for panel layout

Technical Parameters Electrical Ratings Rated Operational Current (Ie): 0.8 … 1.0 A adjustable Number of Poles: 3 Rated Operational Voltage: up to 690 V AC Rated Insulation Voltage (Ui): 690 V Frequency: 50 / 60 Hz Trip Class: Class 10 (thermal overload protection category) Service Short‑Circuit Breaking Capacity: approx. 50 kA @ 400 V AC Protection & Functional Features Motor Protection: Thermal overload protection with adjustable setting Magnetic instantaneous trip for short‑circuit response Phase loss protection Trip‑Free Mechanism: Yes (contacts do not weld under fault) Temperature Compensation: Yes (improves accuracy over ambient range) Switch Function: Manual ON/OFF with clear position indication Padlockable OFF Position: Yes, for maintenance safety Mechanical & Installation Actuation: Rotary handle Terminal Type: Screw terminals Mounting: Panel or DIN‑rail compatible based on accessory/adapter Degree of Protection: IP20 Pollution Degree: 3 Connecting Capacity (main circuit): Typical flexible/rigid conductors appropriate to ~1 A class (e.g., up to ~4–6 mm² depending on terminal) Tightening Torque: Typical motor starter torque range (e.g., ~2–4 N·m) Physical / Environmental Approx. Width: ~45 mm Approx. Height: ~97–100 mm Approx. Depth: ~80–90 mm Net Weight: ~0.20–0.30 kg Operating Ambient Temperature: approx. –25 °C to +60 °C Storage Temperature: broader industrial range

Technical Parameters Electrical Ratings Rated Operational Current (Ie): 25 … 32 A adjustable Number of Poles: 3 Rated Operational Voltage: Up to 690 V AC Rated Insulation Voltage (Ui): 690 V Frequency: 50 / 60 Hz Trip Class: Class 10 (thermal overload protection category) Service Short‑Circuit Breaking Capacity: ~50 kA @ 400 V AC Protection & Functional Features Motor Protection: Thermal overload protection with adjustable setting Magnetic instantaneous trip for short‑circuit response Phase loss protection Trip‑Free Mechanism: Yes (prevents contacts from welding closed under fault) Temperature Compensation: Ensures accurate trip behavior over ambient temperature variations Switch Function: ON/OFF with clear indicator Padlockable OFF Position: Yes, for maintenance safety Mechanical & Installation Control / Actuation: Rotary handle for manual operation Terminal Type: Screw terminals Mounting: Panel or DIN‑rail compatible Degree of Protection: IP20 Pollution Degree: 3 Connecting Capacity (typical): Main circuit: Flexible/rigid up to ~35 mm² depending on terminal Auxiliary circuits: Smaller cross‑sections as appropriate Tightening Torque: Typical motor starter recommended torque (e.g., ~3–6 N·m) Physical / Environmental Approx. Width: ~45 mm Approx. Height: ~97–100 mm Approx. Depth: ~85–90 mm Net Weight: ~0.30–0.35 kg Operating Ambient Temperature: approx. –25 °C to +60 °C Storage Temperature: broader industrial range

SERVICE HOTLINE Grace +86 13600179521