Technical Specifications Specification Value Manufacturer ABB Model / Part Number MEP6‑0 Product Type Empty Pushbutton Enclosure Housing Material Plastic (Polycarbonate) Color Dark Gray / Light Gray Number of Holes / Seats 6 positions Operator Mounting Size 22 mm Compatibility Modular & compact range pilot devices Protection Rating IP66 (dust tight & strong water protection) NEMA Rating 1, 3R, 4, 4X, 12, 13 Standards CE Certified, RoHS Compliant Operating Temperature Up to approx. 70 °C Mounting Style Base or panel mounting Included Hardware Stainless steel screws Typical Use Industrial control panels, pendant stations

Parameter Specification Product Series AF Series (Axial Flow) Enclosures Device Type Plastic Enclosure Kit with DIN Rail and Cover Article Number AF12-30-10-13 Internal DIN Rail Specification 35mm symmetrical DIN rail, compatible with components up to 12mm deep. Included DIN Rail Length Typically 200 mm (This is the common length associated with suffix "13". Must be verified with official datasheet). Enclosure External Width 30 mm (Nominal) Enclosure External Height Standard height for AF12 series (e.g., ~100-110mm). Enclosure External Depth Approximately 30-40mm (to accommodate the 12mm component depth plus rail and wall clearance). Cover Type Opaque grey, snap-on cover (based on suffix "10"). Transparent covers have different codes. Material High-quality plastic (Polycarbonate (PC)), Grey, UL 94 V-0 rated. Protection Degree (IP Rating) IP40 (with cover closed, protected against access with a wire >1mm). Can achieve IP55/IP65 with appropriate sealed covers and gaskets (which may be different models). Mounting Wall or panel mounting via integrated keyhole slots on the back. Operating Temperature Typically -25°C to +70°C

Technical Data Parameter Specification / Typical Value Product Family Accessory for ABB Emax 2 (E2) Air Circuit Breakers Device Type Electronic Under-Voltage Release with Timer Article Number 1SDA063552R3 Rated Supply Voltage (Us) 220 / 240 V AC (50/60 Hz), 3-phase monitoring. Operating Voltage Range Typically 0.85 to 1.1 x Us (e.g., ~187V to 264V). The breaker can be closed within this range. Trip Threshold (U<) Adjustable, typically within a range like 70% to 95% of Us (e.g., ~154V to 228V for 220V). Trip Delay Time (t<) Adjustable, typically within a range like 0.1s to 10s (or similar). This is the key feature to ride through short dips. Reset Voltage Requires voltage to return above the threshold (plus a hysteresis) and often a manual reset of the breaker. Mounting / Compatibility Direct internal mounting onto the designated slot of an Emax 2 breaker specified by the T7/T7M interface code. Connection Wired to the three-phase supply (L1, L2, L3, N) for monitoring. Typically connects internally to the breaker's control circuit. Standards Compliance IEC/EN 60947-2 Ambient Temperature Operation: -25°C to +70°C

Technical Data Parameter Specification / Typical Value Product Series AF Series (Axial Flow) Enclosures Device Type Plastic Enclosure / Wireway (Empty Body) Article Number AF75-40-00 Internal DIN Rail Compatibility 75mm deep, 35mm symmetrical DIN rail (Rail not included with "00" suffix). External Dimensions (Approx., H x W x D) Height: ~110-120mm (Standard height for this series) Width: 40 mm (Nominal) Depth: ~75-80mm (External, depends on design) Note: Exact dimensions must be verified from the datasheet. Material High-quality plastic (e.g., Polycarbonate (PC) or Polyamide (PA)), Grey, UL 94 V-0 rated. Protection Degree (IP Rating) Typically IP40 (Protected against tools and wires >1mm, not against water). With appropriate gasketed cover, can achieve IP55 or higher. Mounting Wall or panel mounting via integrated keyhole slots or screw holes. Transparency The body is opaque. Transparent covers (e.g., AF...-T...) are available as separate accessories. Operating Temperature Typically -25°C to +70°C (Material dependent) Standards Compliance IEC 60529 (IP Rating), UL 508A (for enclosures)

Technical Data Parameter Specification / Typical Value Product Series TINA (Terra Indicating and Auxiliary) Relay Series Device Type Electromechanical Monostable Latching Relay Contact Configuration 2 Normally Open (NO) Contacts (2 Form A) Contact Rating (Main Contacts, Resistive Load) Typically: 10 A @ 250 V AC Switching Capacity: AC-1: Up to 2500 VA per contact Rated Thermal Current (Ith): 16 A Coil Data Multiple voltages available. This is a key variable. The specific coil voltage (e.g., 24 V DC, 110 V AC, 230 V AC) is defined by the full article number, not just "TINA 2A". Coil Power Consumption DC coil: ~0.9 W AC coil: ~1.3 VA Mechanical Life ≥ 10 x 10⁶ operations Electrical Life (at rated load) ≥ 0.2 x 10⁶ operations Operate/Release Time Typically ~10 ms Mounting Plug-in module onto a compatible TINA series DIN-rail mounting base (sold separately). Terminal Type (on base) Screw clamp terminals. Connection Capacity Up to 2.5 mm² Status Indication Mechanical flag (red). Ambient Temperature (Operation) -40°C to +70°C Protection Degree IP40 (with base), IP20 (terminals) Standards Compliance IEC/EN 61810-1, IEC/EN 60947-5-1

Technical Data Parameter Specification / Typical Value Product Family Robot Peripherals / Operator Interface for ABB XRC & XR Robot Controllers Device Type Panel Mount Operator Interface Box (with Integrated Safety Functions) Compatible Controllers ABB XRC Series Controllers (e.g., for IRB 1400, 2400, 4400, 6400 robots) ABB XR Series Controllers (later models) Core Safety Components • 3-Position Enabling Device (Cat. 3 / PLd safety rated) • Emergency Stop Button (Dual-channel, with latching mechanism) • Mode Selector Key Switch (At least 2 positions) Operational Buttons • Start (Green) • Stop/Halt (Yellow) • Motor On (May be integrated) • Other function keys (Model dependent) Status Indicators • Power On (Green) • Program Running (Green) • Fault/Error (Red/Amber) • Safety Circuit Status (Specific color) Protection Degree Typically IP65 (Front panel, dust-tight and protected against water jets) Supply Voltage Typically provided by the connected robot controller via the interface cable as 24 V DC. Communication Interface Connects to the controller's rear panel via a dedicated multi-pin circular connector (e.g., to the X8 port). Internal wiring is predefined and standardized. Mounting Panel cut-out mounting, secured by a front bezel nut. Standard cut-out dimensions apply (e.g., 96mm x 96mm or similar). Ambient Temperature Operation: 0°C to +50°C Safety Standards Complies with ISO 10218-1, ANSI/RIA R15.06 for robot control devices. Internal safety circuits comply with IEC 60204-1, IEC 61800-5-2, etc.

Parameter Specification Product Family Accessory for ABB Emax 2 (E2) Air Circuit Breakers Device Type Electronic Undervoltage Release (UVR) / Undervoltage Trip Coil Rated Supply Voltage (Us) 220 - 250 V AC / 220 - 250 V DC Operating Voltage Range 0.85 to 1.1 x Us (e.g., ~187V to 275V). The breaker can be closed within this range. Trip Threshold Typically 35% to 70% of Us (e.g., ~77V to 175V). The breaker will trip when voltage falls below this threshold after a short time delay (to avoid nuisance trips on transient dips). Trip Delay Time Typically adjustable (e.g., 0.1s to 10s) or fixed (e.g., < 1s). This prevents tripping on momentary voltage dips. Reset Voltage Typically requires voltage to return to >85% Us before the release can be reset and the breaker re-closed. Power Consumption Typically a few VA/W when energized. Mounting / Compatibility Direct internal mounting onto the designated slot of an Emax 2 breaker. The T4-5 code specifies exact compatibility with specific frame sizes (e.g., E2.2, E2.4) and operating mechanisms. Connection Wired to an external control power supply via terminals on the breaker or the release itself. Standards Compliance IEC/EN 60947-2 Ambient Temperature -25°C to +70°C (Operation)

Parameter Specification Device Type 3-Pole Rotary Load Break Switch / Disconnector Product Series MJ / MJS Series Rated Operational Current (Ie) 60 A (per pole, at specified utilization category) Number of Poles 3 Poles (3P) Rated Insulation Voltage (Ui) 690 V Rated Operational Voltage (Ue) 400 V AC / 500 V AC (3-phase) Utilization Category AC-22A (Switching of mixed resistive and inductive loads). AC-23A (Switching of motor loads or other highly inductive loads). Rated Making & Breaking Capacity Typically ≥ 10 x Ie (e.g., 600 A per phase) for AC-23A at 400V. Short-Time Withstand Current (Icw) Typically 10 kA for 1 second (A critical safety parameter ensuring it can withstand fault currents without damage to the isolation path). Mechanical Durability ≥ 10,000 operations Electrical Durability ≥ 5,000 operations (at rated current) Control Method Manual rotary operation via a detachable handle. Handle can be padlocked in the OFF position (commonly with up to 3 padlocks). Mounting Mounts directly onto a panel or enclosure door via a mounting kit. The switch body is installed behind the panel. Terminal Type Screw clamp terminals. The "B" variant often includes snap-on protective terminal covers. Terminal Connection Capacity Typically up to 35 mm² (for the 60A model). Protection Degree Switch body: IP00 (must be installed inside an enclosure). With handle mounted on door: Typically achieves IP54 or higher for the front. Ambient Temperature (Operation) -25°C to +60°C Standards Compliance IEC/EN 60947-1, IEC/EN 60947-3

Parameter Specification Product Line / Series System Pro M compact S200 (S200 Series) Device Type Miniature Circuit Breaker (MCB) with B Curve Poles 3P (Three Poles) Rated Current (Iₙ) 6 A (per pole) Rated Voltage (Uₙ) 400 V AC (3-phase) Rated Frequency 50/60 Hz Breaking Capacity (Icn) 6 kA (at 400V AC). This is the standard value for the base S200 series. Tripping Characteristic B Curve (Instantaneous magnetic trip operates between 3 to 5 times Iₙ, i.e., between 18A and 30A per pole). This provides fast, sensitive protection ideal for circuits with long cable runs or where limiting let-through energy is critical. Mechanical Endurance ≥ 20,000 operations Electrical Endurance ≥ 10,000 operations (at Iₙ) Mounting 35 mm symmetrical DIN rail (EN 60715) Width 54 mm (3 standard modules, each 18mm) Terminal Torque 1.5 - 2.0 Nm (for rated cross-section conductors) Connection Capacity Rigid Cable: Up to 25 mm² (per pole) Flexible Cable: Up to 16 mm² (with ferrule recommended, per pole) Standards Compliance IEC/EN 60898-1, IEC/EN 60947-2 Ambient Temperature (Operation) -25°C to +55°C

Parameter Specification Product Line / Series System Pro M compact S200 (S200 Series) Device Type Miniature Circuit Breaker (MCB) with K Curve Poles 2P (Two Poles) Rated Current (Iₙ) 6 A Rated Voltage (Uₙ) 230/400 V AC Rated Frequency 50/60 Hz Breaking Capacity (Icn) 6 kA (at 230/400V AC). This is the standard value for the base S200 series. Tripping Characteristic K Curve (Instantaneous magnetic trip operates between approximately 8 to 14 times Iₙ, i.e., between ~48A and ~84A). This provides a balanced solution for high-inrush, low-power loads. Mechanical Endurance ≥ 20,000 operations Electrical Endurance ≥ 10,000 operations (at Iₙ) Mounting 35 mm symmetrical DIN rail (EN 60715) Width 36 mm (2 standard modules, each 18mm) Terminal Torque 1.5 - 2.0 Nm (for rated cross-section conductors) Connection Capacity Rigid Cable: Up to 25 mm² Flexible Cable: Up to 16 mm² (with ferrule recommended) Standards Compliance IEC/EN 60898-1, IEC/EN 60947-2 Ambient Temperature (Operation) -25°C to +55°C

Parameter Specification / Typical Value Product Series TINA (Terra Indicating and Auxiliary) Relay Series Device Type Electromechanical Latching Relay Contact Configuration 4 Normally Open (NO) Contacts (4 Form A) Contact Rating (Main Contacts) Typically: 10 A @ 250 V AC (Resistive load per contact) Switching Capacity: AC-1: Up to 2500 VA per contact Rated Thermal Current (Ith): 16 A Coil Power Consumption DC: ~0.9 W AC: ~1.3 VA Mechanical Life ≥ 10 x 10⁶ operations Electrical Life (at rated load) ≥ 0.2 x 10⁶ operations Operate/Release Time Typically ~10 ms Mounting 35 mm symmetrical DIN rail via a plug-in base (e.g., ABB TINA base). The relay module plugs into the base. Terminal Type (on base) Screw clamp terminals. Connection Capacity Up to 2.5 mm² Ambient Temperature (Operation) -40°C to +70°C Protection Degree IP40 (with base), IP20 (terminals) Standards Compliance IEC/EN 61810-1, IEC/EN 60947-5-1

Parameter Specification Product Series E290 Series (Modular Timing Relays) Device Type Electromechanical On-Delay Timer (Delay on Make) Function Code On-Delay (11) Output Contact Configuration 1 Changeover Contact (SPDT / 1 CO) – 1 NO + 1 NC Contact Rating (Resistive Load) 16 A @ 250 V AC Rated Control Supply Voltage (Us) 230 V AC (50/60 Hz) Supply Voltage Range Typically 0.85...1.1 x Us (e.g., ~195...253 V AC) Power Consumption Typically 3...5 VA (for AC models) Time Delay Range Variable. Depends on the specific sub-model (e.g., E290-16-11/230 0.1s-10h). Common ranges include: 0.05s - 10min, 0.5s - 10h, etc. Must be verified from the marking or datasheet. Setting Accuracy Typically ±5% of set value or ±30ms (whichever is greater). Repeat Accuracy Typically ±2% of set value or ±20ms. Reset Time < 100 ms Mechanical Life ≥ 10 x 10⁶ operations Electrical Life ≥ 0.2 x 10⁶ operations (at rated load) Mounting Plug-in module onto a compatible 8 or 11-pin DIN rail socket (e.g., ABB PKZ or similar series socket). Ambient Temperature Operation: -20°C to +55°C Storage: -40°C to +85°C Standards Compliance IEC/EN 61810-1, IEC/EN 60947-5-1