Industrial Controller
All product are in stock,guaranteed delivery within 3-7 days.
Infinite Innovation, the Future of Industrial Control Systems
Infinite Innovation, the Future of Industrial Control Systems
PRODUCT HOME>>PRODUCT
PRODUCT

PRODUCT

PICTURE

BRAND

DESCRIBE

STOCK

DOWNLOAD

Technical Parameters Mechanical Shaft Compatibility: 6 mm square shaft. Handle Length: ~65 mm ergonomic grip. Mounting: Mounted on front of panel or enclosure; shaft ordered separately to match panel thickness and internal mechanism. Operation: Manual ON/OFF rotation controlling the connected disconnect switch. Environmental & Protection Protection Rating: High ingress protection suitable for panel front — withstands dust and water exposure. NEMA/IEC Ratings: Compatible with typical industrial enclosure standards (e.g., outdoor/indoor environments requiring NEMA 1, 3R, 12 levels of protection). Durability: Designed for industrial control environments with frequent use. Safety & Lockout Padlock Provision: Accepts up to three padlocks in the OFF position to secure the disconnect. Door Interlock: The handle mechanism includes a door interlock feature when in ON position, improving safety by restricting access unless the circuit is disconnected (this interlock can be overridden when needed for inspection). Typical Applications Manual isolation of power circuits via switch disconnectors in industrial panels. Operator actuation of load‑break switches and safety disconnects. Lockout/tagout procedures in maintenance and safety shutdowns. Electrical distribution gear and machinery panels where robust manual handles are required.

Technical Parameters Mechanical Positions: 2 maintained positions — switch stays in selected position until manually changed. Mounting: Standard 22 mm panel mounting. Operator Type: Modular selector — requires separate contact block(s). Mechanical Durability: Designed for a high number of operator cycles. Electrical (via Contact Blocks, Sold Separately) Contact Blocks Required: Must be selected and installed behind the operator to provide electrical switching. Contact Configuration Options: Determined by contact blocks chosen (NO, NC, combinations). Rated Insulation Voltage: Designed to meet typical low‑voltage control circuit requirements. Rated Operational Voltage & Current: Depends on the contact blocks used (typically suitable for pilot duty control circuits). Environmental Operating Temperature Range: Suitable for standard industrial ambient conditions. Storage Temperature Range: Extended range for safe transport and storage. Protection Ratings: Front Panel: High ingress protection when installed properly (resistant to dust and splash). Terminals: Basic protection at the terminals when enclosed. Physical Dimensions Operator Diameter: Approx. 29 mm. Overall Depth: Compact profile behind panel. Weight: Lightweight unit suitable for modular panel assemblies. Typical Applications Mode selection (e.g., On/Off, Auto/Manual) in control panels. Operator interface for machinery controls and automation systems. PLC or relay logic input selection. Flexible control functions when paired with appropriate contact blocks.

Key Features Operator Type: Key‑operated selector switch with removable key. Positions & Action: 2‑position maintained action — remains in the selected position until changed manually. Contacts: Integrated 2 normally open (NO) + 2 normally closed (NC) contacts, enabling multiple circuit switching functions. Actuator: Key‑activated rotary selector (provides secure control and prevents accidental actuation). Construction: Modular plastic housing suited for industrial control panel mounting. Front Protection: High ingress protection on the front panel when installed (dust and water resistance). Terminal Connections: Screw‑type terminals for secure wiring. Electrical Ratings Rated Control Voltage: Suitable for typical industrial control voltages (AC/DC supply). Rated Insulation Voltage: Designed for low‑voltage control circuits (up to ~690 V). Contact Rating: Suitable for AC and DC control loads within typical pilot device ratings. Functional control of relays, PLC inputs, contactors, and indicator circuits. Mechanical & Environmental Mounting: Standard 22 mm panel cut‑out for pilot devices. Mechanical Durability: Designed for a high number of operation cycles in control panel environments. Operating Temperature Range: Suitable for typical industrial ambient conditions (approx. –25 °C to +70 °C). Storage Temperature Range: Broader range for transport and storage. Front Protection Rating: High degree of dust and water resistance when mounted properly; terminals are protected when enclosed. Physical & Installation Dimensions: Fits standard 22 mm panel hole and aligns with modular pilot device layouts. Bezel / Housing: Durable plastic construction for rugged installation. Key: Removable key provides security and can be configured to be removed in one or both positions by variant. Typical Applications Control panel selector for mode or function control (e.g., Off/On, Manual/Auto). Secure operator interface where key‑only access is needed. PLC or relay control inputs requiring two distinct switch states. Machine and automation systems where human intervention is controlled by key operation.

Parameters Rated Current (In): 63 A continuous. Rated Operational Voltage (Ur): 690 V AC (typical low‑voltage distribution). Fuse Type / Utilization Category: gG — general purpose fuse link for conductor and equipment protection. Short‑Circuit Withstand: High rupture capacity suited for industrial fault levels. Standards Compliance: Designed to meet IEC 60269 series standards for low‑voltage fuses. Mechanical & Physical Fuse Size: NH000 — compact cartridge suitable for miniature switchgear and compact fuse bases. Construction: Robust metallic and ceramic body rated for reliable mechanical and electrical performance under load. Mounting: Installed in appropriate fuse holder or disconnect switch base designed for NH000 links. Dimensions (Typical NH000): Compact rectangular profile suitable for DIN rail or panel mount assemblies. Environmental Operates reliably across standard industrial ambient temperatures. Designed for indoor electrical panel environments with adequate ventilation. Fuse body materials suitable for normal electrical installation conditions. Typical Applications Protection of distribution circuits in industrial and commercial power panels. Motor and transformer protection downstream of disconnect switches or starters. Overcurrent and short‑circuit protection in control and power systems. Modular low‑voltage switchgear requiring standardized fuse link sizes.

Key Features Selector Type: 3‑position maintained rotary switch — stays in the selected position until manually changed. Actuator: Short red handle for clear manual selection and easy operation. Illumination: Non‑illuminated — no built‑in lamp or LED. Compact Construction: Space‑efficient design tailored for panel mounting. Durability: Suitable for industrial environments, designed for frequent use. Contact Configuration: Two normally open (2NO) auxiliary contacts — useful for switching control circuits. Electrical Ratings Rated Operational Voltage: Suitable for low‑voltage AC/DC control circuits (up to ~300 V). Rated Operational Current: AC‑15 control duty currents typical for operator devices (e.g., ~1 A at ~220–240 V AC; higher at lower voltages). DC‑13 duty capability at lower DC voltages (e.g., ~0.2–0.3 A at 24–125 V DC). Insulation & Impulse Withstand: Designed with appropriate insulation and transient withstand levels for control‑circuit switching. Mechanical & Environmental Positions: 3 fixed positions with maintained action (no spring return from main positions). Mechanical Durability: Designed for a high number of operations (hundreds of thousands). Operating Temperature Range: Typical industrial ambient temperatures (approx. –25 °C to +70 °C). Storage Temperature Range: Broader temperature range for transport and storage. Protection: Front: High ingress protection (dust and water resistance) when mounted properly. Terminals: Basic touch protection at terminals when installed in an enclosure. Physical & Installation Panel Cut‑out: Standard 22 mm diameter hole for pilot devices. Body / Bezel: Durable plastic body and bezel for panel mounting. Terminal Type: Screw‑type terminals for secure wiring connections. Compact Size: Slim profile for efficient space usage in control cabinets. Typical Applications Mode selection (e.g., Off/Auto/Manual) in machine control panels. Control logic inputs for PLCs, relays, and contactors. Industrial automation systems needing discrete manual position selection. Operator interfaces in production equipment.

Technical Parameters Electrical Contact Configuration: Typically 1 normally open (NO) and 1 normally closed (NC) auxiliary contact (common configuration for this variant). Rated Insulation Voltage: Up to ~300 V AC/DC suitable for low‑voltage control circuits. Rated Operational Voltage: Up to 300 V AC/DC. Rated Operational Current: Appropriate for typical pilot duty control circuits (generally up to ~1 A at 220–240 V AC and lower for DC). Mechanical & Environmental Positions: Three fixed/manual positions (e.g., A — B — C). Function Type: Maintained action — remains in position until manually moved. Mechanical Durability: Designed for many make/break switching cycles. Operating Temperature Range: Typical industrial ambient range (~–25 °C to +70 °C). Storage Temperature Range: Wider storage range (~–40 °C to +85 °C). Protection (Front/Terminals): Offers degree of protection with high dust/water resistance on the actuator; basic terminal protection. Physical & Installation Panel Cut‑out: Standard 22 mm hole for pilot devices. Actuator/Handle: Long red handle for ease of operation. Bezel/Housing: Plastic bezel and body for durability and panel integration. Terminal Type: Screw‑type terminals for secure electrical connections. Typical Applications Mode selection (e.g., Off/Auto/Manual) or multi‑position control in automation panels. Operator interfaces for machinery, conveyors, and process equipment. Control logic inputs for PLC and relay systems. General purpose three‑position manual control.

Technical Parameters Physical Width: 4.6 mm Length: 190 mm Bundle Capacity: Suitable for bundling cables from approximately 3.0 mm up to ~46 mm in diameter. Minimum Tensile Strength: Suitable for general electrical harnessing and panel routing. Environmental Operating Temperature: Typically works in a wide ambient range suitable for industrial environments. Storage Temperature: Stable under standard storage conditions. Flammability: Meets standard nylon flammability characteristics. Mechanical Locking: Integrated self‑locking mechanism — no additional hardware required. Bending / Flexibility: Nylon construction offers a balance of flexibility and strength for panel routing and strain relief. Typical Applications Cable harnessing in control panels, distribution boards, and electrical enclosures. Routing and bundling of signal, power, and control cables in industrial installations. Securing cable bundles in machinery, automation equipment, and wiring troughs. General purpose wire management in commercial and residential projects.

Key Features Provides four auxiliary contacts in a compact block — 2 normally open (2 NO) and 2 normally closed (2 NC) configurations. Front‑mount design allows simple installation on compatible contactors without additional hardware. Screw‑type terminals for secure and reliable field wiring. Suitable for use with a range of ABB contactors, enabling expanded control and monitoring functions. Compact and modular, ideal for dense control panel installations. Electrical Ratings Contact Configuration: 2 NO + 2 NC auxiliary contacts. Rated Operational Voltage (Auxiliary): Up to approximately 690 V AC in auxiliary circuits. Rated Operational Current: Up to 6 A at lower AC voltages (e.g., 24–127 V AC). Around 2 A at higher AC voltages (e.g., ~500–690 V AC). Suitable for AC and DC control circuits within common industrial ranges. Typical switching categories: Support for control duty (AC‑15 / DC‑13) loads with appropriate current ratings. Mechanical & Environmental Mounting Style: Front‑mounted onto compatible contactors (e.g., AF09…AF16 range). Terminals: Screw clamp terminals for secure conductor connection. Durability: Designed for frequent make/break operations in industrial control applications. Protection: Touch‑protected terminals (equivalent to IP20) when installed in an enclosure. Physical & Installation Number of Poles: 4 auxiliary poles with independent contacts. Compact Size: Space‑efficient footprint for dense panel layouts. Designed to integrate seamlessly with matched contactor series for combined main and auxiliary switching. Typical Applications Feedback circuits for motor starters and contactor status indication. PLC/relay input expansion where additional auxiliary contacts are needed. Interlocking and safety logic in control panels. Monitoring and control signaling alongside primary switching devices.

Key Features Contactor Type: Three‑pole contactor for switching and control of power circuits. Control Voltage Range: Operates on a wide coil voltage range suitable for both AC and DC control inputs. Low Coil Consumption: Designed for reduced power usage in the control circuit. Built‑in Surge Protection: Improves durability and helps protect the coil from electrical transients. Modular Design: Can be expanded with auxiliary and accessory blocks on the front or sides as needed. Compact Footprint: Space‑efficient design for control panels and motor starters. Electrical Ratings Main Contact Configuration: 3 normally open (3NO) main poles. Auxiliary Contact: 1 normally closed (1NC) auxiliary contact built in. Rated Operational Voltage (Main Circuit): Up to 690 V AC (IEC) or 600 V AC (UL). Rated Continuous Current: Up to 30 A in AC‑1 applications. AC‑3 Motor Load Capability: Suitable for typical motor control duties with lower current at higher voltages. Control Coil Voltage Range: Operates from approximately 24 V to 60 V AC (50/60 Hz) or 20 V to 60 V DC — accepts wide control voltage fluctuations without coil changes. Horsepower Ratings: Rated for typical motor loads across voltage ranges (e.g., multiple horsepower levels depending on supply voltage). Mechanical & Environmental Number of Poles: 3 main poles. Mechanical Endurance: Designed for a high number of operations suitable for frequent switching. Operating Temperature Range: Suitable for standard industrial ambient conditions (~‑40 °C to +70 °C or similar). Protection Rating: Basic enclosure protection (e.g., IP20) at terminals when installed in an enclosure. Physical & Installation Mounting: Designed for panel or DIN‑rail mounting using appropriate sockets or accessories. Terminal Type: Screw‑type terminals for secure wiring of main, auxiliary, and control circuits. Dimensions (Approximate): Compact profile with modest width, depth, and height for space‑efficient panel layout. Weight: Lightweight for easy handling and installation. Typical Applications Motor control: Switching three‑phase motors in industrial systems. Power circuits: Controlling contactor loads in machinery, pumps, compressors, HVAC, and general power switching. Automation systems: Interface between control logic (PLC outputs, switches) and heavy loads. Control panels: Main or auxiliary switching device in panels requiring reliable contact operations.

Key Features Switch‑Fuse Disconnect: Combines manual switching and fuse protection in one device for simplified panel design. 3‑Pole Unit: Designed to isolate three‑phase circuits or three separate conductors simultaneously. Front Operation: Handle and shaft allow operation from the front of the panel. Adjustable Shaft: Handle shaft length can accommodate different panel depths. Padlockable OFF Position: Handle can be locked in the OFF position for safety lockout/tagout procedures. Door Interlock Capability: Prevents opening the enclosure door when the switch is ON for added safety. DIN Mountable: Compact size suitable for panel mounting with standard hole patterns. Electrical Ratings Rated Operational Current: 32 A continuous current capacity for main circuits. Rated Operational Voltage: Up to 690 V AC in low‑voltage distribution systems. Rated Operational Current Categories: AC‑21A (general switching) AC‑22A (switching mixed resistive and inductive loads) AC‑23A (motor load switching) — all rated at 32 A for a range of voltages. Rated Operational Power (AC‑23): ~7.5 kW at 220–240 V ~15 kW at 400–415 V ~18.5 kW at 500 V ~22 kW at 690 V. Short‑Circuit & Withstand Rated Short‑Time Withstand Current: approx. 2.5 kA RMS for 1 second. Rated Conditional Short‑Circuit Current: up to ~80 kA (conditional). Rated Insulation Voltage: ~1000 V. Rated Impulse Withstand Voltage: ~12 kV. Mechanical & Installation Number of Poles: 3. Fuse Type: Designed to accept NH000‑series fuse inserts. Operating Mechanism: Manual front‑mounted rotary handle. Terminal Connections: Screw‑type terminals accommodating cable sizes from approximately 2.5 mm² up to 25 mm². Tightening Torque: Specified torque values suitable for secure conductor connections. Environmental & Protection Pollution Degree: 3 (industrial environment). Protection at Terminals: Basic touch protection when installed in an enclosure (IP20). Handle Ingress Protection: Handle may provide higher IP protection (e.g., IP65) on the front panel if correctly installed. Physical Dimensions & Weight Approximate Width: ~112 mm Approximate Height: ~125 mm Approximate Depth: ~121 mm Weight: ~1.18 kg This size makes it suitable for robust panel integration without excessive space demand. Typical Applications Manual isolation and overload protection in industrial electrical panels. Three‑phase power distribution break and fuse assembly. Safety disconnect for machinery and equipment where fuse protection and manual disconnect are needed. Integration into motor control centers (MCC), switchboards, and distribution boards.

Key Features Rotary Handle Mechanism: Provides manual ON/OFF operation of the connected circuit breaker. Adjustable Depth: Long operator shaft (~500 mm) accommodates panels or enclosures of varying thickness. Padlock Capability: Supports padlocking in the OFF position for safety lockout/tagout procedures. Door Interlock: Prevents door opening when the breaker is in the ON position, enhancing safety. Designed For: Fixed‑withdrawable T7 series moulded case circuit breakers. Mechanical & Installation Operating Method: Rotary handle turns the breaker’s internal mechanism via a shaft connection. Mounting Type: Front‑mounted to panel or enclosure cut‑out with adjustable depth shaft to reach the breaker. Shaft Length: Approximately 500 mm adjustable. Handle Style: Ergonomic rotary knob designed for clear manual control. Compatibility: Intended for use with ABB T7 fixed‑withdrawable MCCBs. Environmental & Safety Padlock Device: Allows up to multiple padlocks to secure the switch in OFF condition. Door Interlock Feature: Enhances safety by mechanically preventing door opening when the breaker is ON. Robust Design: Suitable for industrial panel environments. Physical & Dimensions Adjustable Shaft Length: ~500 mm Weight: Moderate, suitable for panel mounting. Finish: Durable finish for industrial use. Typical Applications Manual operation of T7 series moulded case circuit breakers. Safety isolation points in control and distribution panels. Maintenance lockout/tagout procedures, using padlock facility. Industrial control panels requiring external breaker handle actuation.

Key Features Selector Type: 2‑position maintained selector switch. Actuator: Short black handle/knob for manual operation. Illumination: Non‑illuminated design (no lamp or LED). Color & Housing: Black plastic bezel and body for durability and panel integration. Contact Configuration: 1 normally open (1 NO) contact. Positions: Maintained at both fixed positions (A and C). Panel Mounting: Designed for a 22 mm panel cut‑out in standard control panels. Electrical Ratings Rated Operational Voltage: Suitable for typical control voltages (AC/DC). Contact Ratings: Approximately 1.5 A at lower AC control voltages (e.g., 24 V to 127 V AC). Approximately 1 A at higher AC voltages (e.g., 220–240 V AC). Lower current capability for DC control circuits. Switching Function: Maintained switching of the controlled circuit — stays in the selected position until manually changed. Mechanical & Environmental Actuator Movement: Fixed positions with maintained action — no spring return. Mechanical Durability: Designed for a substantial number of actuation cycles. Operating Temperature Range: Suitable for typical industrial ambient environments. Storage Temperature Range: Broad range for transport and storage. Protection Rating: Front Protection: Designed for panel mounting with resistance to dust and water in control panels. Terminal Protection: Basic touch protection at terminals when enclosed. Physical & Installation Mounting Size: Standard 22 mm diameter panel cut‑out. Dimensions: Compact form factor ideal for control panel integration. Terminals: Screw‑type terminal connections for reliable wiring. Typical Applications Mode selection (e.g., On/Off, Auto/Manual) in control panels. Control logic inputs for PLCs, contactors, and relay systems. Operator interfaces where simple maintained position selection is required. Industrial automation and machine controls that need a compact, maintained selector switch.

SERVICE HOTLINE Grace +86 13600179521
Mail info@hongkongeasy.com jilineasyyi@outlook.com ADDRESS Unit 12, 20th Floor, Good View Commercial Centre, 2-16 Garden Street, Mong Kok, Hong Kong
Q Q: 615739355
吉林易择科技技术发展有限公司 吉ICP备2024020526号-1
js
0.850934s