Technical Specifications: Parameter Category Specification Detail Model Designation ACS310-03E-17A2-4 Product Series ABB ACS310 General Purpose Drive Rated Power 7.5 kW (10 HP) Output Current 17.2 A (at 400V, continuous duty) Supply Voltage 3-phase, 380 - 480 V AC (±10%), 50/60 Hz Output Voltage 0 - Supply Voltage (Uin) Output Frequency Range 0.1 - 500 Hz Control Method Scalar Control (V/Hz) with programmable V/Hz curves (linear, quadratic, user-defined) Control Performance - Speed control range: 1:40 - Speed control accuracy: ±0.5% of maximum speed (20-50 Hz) - Starting torque: Up to 160% at 0.5 Hz - Torque boost: Adjustable (0-30%) Enclosure Rating IP20 / UL Type 1 (Open Chassis) - Must be installed in suitable enclosure Physical Frame Size R3 Key Features - Quick Setup Macros: 5 pre-defined application settings - Flying Start: Can catch rotating motors in both directions - Energy Optimizer: Reduces motor losses at light loads - Process PID Controller: Built-in for basic process control - Automatic DC Magnetization: Improves starting performance - Automatic Restart: Configurable after fault or power loss - Motor Thermal Protection: I²t model with PTC thermistor option Input/Output Configuration Digital Inputs (DI): 3 (24V DC, sink/source selectable, DI3 can be used as pulse input) Analog Input (AI): 1 (switchable 0-10V/0-20mA) Analog Output (AO): 1 (programmable 0-20mA or 0-10V) Relay Output (RO): 1 (changeover contact, 30V DC/250V AC, 2A) Additional I/O: Optional expansion modules available Communication Interfaces Standard: - Modbus RTU via RS-485 (terminals +A/-B) Optional (via adapters): - PROFIBUS DP - DeviceNet - CANopen - Ethernet (with optional modules) Protection Features Motor Protection: - Motor thermal overload (I²t) with separate motor models - Stall prevention (SUP/OL2) - Phase imbalance detection - Earth fault detection - Underload protection Drive Protection: - Short circuit (SC) - Overcurrent (OC, 200% for 60s) - Overvoltage/Undervoltage (OV/UV) - Heatsink overtemperature (OH) - IGBT temperature monitoring - Motor cable supervision - Input phase loss Energy Saving Features - Automatic Energy Optimizer (reduces magnetizing current) - ECO Mode for fan/pump applications - Sleep/Wake Function with timer - Power Factor: Typically >0.98 Braking Capability - DC Braking: Standard (torque 0-100%, time 0-60s) - Dynamic Braking: Requires optional brake resistor - Ramp Times: 0.1-1800s (acceleration/deceleration) Cooling System Forced air cooling with temperature-controlled fan Environmental Specifications Operating Temperature: -15°C to +50°C (5°F to 122°F) without derating Storage Temperature: -40°C to +70°C (-40°F to 158°F) Relative Humidity: <95% non-condensing Altitude: 0-1000m without derating (1% per 100m above 1000m) Vibration: 0.7G (5-200 Hz) Pollution Degree: 2 according to IEC 60664 Overvoltage Category: III Electrical Standards & Approvals Certifications: - CE compliant (EMC Directive 2014/30/EU, LVD 2014/35/EU) - cULus listed (UL508C) - RoHS compliant - EN/IEC 61800-3 compliant (EMC) - EN/IEC 61800-5-1 (Safety) Physical Dimensions & Weight Height: 243 mm (9.57 in) Width: 165 mm (6.50 in) Depth: 178 mm (7.01 in) Weight: 3.5 kg (7.7 lb) Mounting Requirements Clearances: - Above/Below: 100 mm minimum - Sides: 50 mm minimum - Mounting position: Vertical (recommended) Torque Settings: - Power terminals: 2.0 Nm - Control terminals: 0.5 Nm
Technical Specifications: Parameter Category Specification Detail Model Designation ACS310-03E-13A8-4 Product Series ABB ACS310 General Purpose Drive Rated Power 5.5 kW (7.5 HP) Output Current 13.8 A (at 400V, continuous duty) Supply Voltage 3-phase, 380 - 480 V AC (±10%), 50/60 Hz Output Voltage 0 - Supply Voltage (Uin) Output Frequency Range 0.1 - 500 Hz Control Method Scalar Control (V/Hz) with four selectable curves (linear, quadratic, free programmable, multi-point) Enclosure Rating IP20 / UL Type 1 (Open Chassis) - Requires protective enclosure Physical Frame Size R3 Key Features - Plug-and-Play Setup: Pre-programmed macro configurations - Flying Start: Can connect to rotating motor - Motor Thermal Protection: I²t with separate motor models - Automatic Energy Optimization: Reduces motor losses at partial loads - Constant Speed Mode: Operates at preset speeds - Process PID Controller: Built-in for pressure/flow/temperature control - Automatic Restart: After mains or fault condition Input/Output Configuration Digital Inputs: 3 programmable (24V DC) Analog Inputs: 1 (0/4-20mA or 0-10V selectable) Analog Output: 1 (0/4-20mA or 0-10V configurable) Relay Outputs: 1 (changeover contact, 30V DC/250V AC, 2A) Optional I/O: Can be expanded with optional modules Communication Interfaces Built-in: - Modbus RTU (RS-485) standard Optional Fieldbus: - Profibus DP - DeviceNet - CANopen (via optional plug-in adapters) Protection Features Motor Protection: - Motor thermal overload (I²t) - Stall prevention (overload/speed loss) - Underload protection - Phase imbalance monitoring Drive Protection: - Short circuit (IGBT monitoring) - Ground fault detection - Overcurrent (200% for 60s, 250% for 2s) - Overvoltage/Undervoltage - Heatsink overtemperature - Motor cable supervision Control Performance - Speed Control Range: 1:40 - Speed Control Accuracy: ±0.5% of maximum speed - Starting Torque: 160% at 0.5 Hz - Torque Boost: Manual or automatic Energy Saving Features - Automatic Energy Optimizer - ECO mode for partial load optimization - Standby function with timer - Mains monitoring for power quality Cooling System Forced air cooling with integrated fan Environmental Specifications Operating Temperature: -15°C to +50°C (5°F to 122°F) without derating Storage Temperature: -40°C to +70°C (-40°F to 158°F) Relative Humidity: 5% to 95% non-condensing Altitude: Up to 1000m (3280 ft) without derating Vibration: 0.7G (5-200 Hz) Installation: Up to 1000m above sea level Electrical Standards & Approvals Compliance: - CE marked - UL listed (UL508C) - cUL listed - RoHS compliant - Complies with EN/IEC 61800-3 - EMC Directive 2014/30/EU - Low Voltage Directive 2014/35/EU Physical Dimensions Height: 243 mm (9.57 in) Width: 165 mm (6.50 in) Depth: 178 mm (7.01 in) Weight: Approximately 3.5 kg (7.7 lb)
Technical Specifications: Parameter Category Specification Detail Model Designation ACH550-01-012A-4 Product Series ABB ACH550 HVAC Drive Rated Power 5.5 kW (7.5 HP) Output Current 12.0 A (at 400V, continuous duty) Supply Voltage 3-phase, 380 - 480 V AC (±10%), 50/60 Hz Output Voltage 0 - Supply Voltage (Uin) Output Frequency Range 0.1 - 500 Hz (Standard HVAC application range: 0.1 - 120 Hz) Control Methodology Sensorless Flux Vector Control (FVC) with automatic energy optimization Control Characteristics - Speed control accuracy: ±0.1% of nominal speed (with auto-tuning) - Torque control response time: 5-10 ms - Speed control range: 1:100 (open loop) Enclosure Rating IP20 / UL Type 1 (Open Chassis) - Requires installation in appropriate control panel Physical Frame Size R2 Key Application Features - Adaptive Programming (AP) with plain-language setup wizard - Energy Optimizer with real-time efficiency monitoring - HVAC-specific Application Macros: Pump, Fan, Constant Pressure, Constant Flow - Dual Independent PID Controllers with cascade control capability - PID Sleep/Wake Function with configurable hysteresis - Automatic Pump Alternation (with optional I/O expansion) - Flying Start and Catch a Spinning Motor function - Motor preheating function for humid environments Input/Output Configuration Digital Inputs: 4 programmable (24V DC, PNP/NPN selectable) Analog Inputs: 2 (AI1: 0-10V/0-20mA, AI2: 0-10V/0-20mA/PT1000) Analog Output: 1 (0/4-20mA or 0-10V configurable) Relay Outputs: 2 programmable (RA01: 30V DC/250V AC, 2A; RA02: 30V DC/250V AC, 2A) Additional: PTC thermistor input for direct motor temperature monitoring Communication Interfaces Built-in: - BACnet MS/TP (Standard protocol for building automation) - Modbus RTU (RS-485) Optional Fieldbus: - Profibus DP - LonWorks - Ethernet/IP - Modbus TCP/IP (via optional adapters) Protection Features Motor Protection: - I²t thermal overload protection - Motor stall prevention - Phase imbalance protection - Earth fault detection Drive Protection:<br- DC bus overvoltage/undervoltage - Output short circuit - Overcurrent (200% for 60s, 300% for 2s) - Heatsink overtemperature - Control board temperature monitoring - Input phase loss detection Energy Saving Features - Automatic Energy Optimizer reduces magnetizing current - Power factor correction (>0.98) - Adaptive current limit - Standby mode with automatic wake-up - Energy consumption monitoring (kWh counter) Cooling System Forced air cooling with temperature-controlled fan Environmental Specifications Operating Temperature: -15°C to +50°C (5°F to 122°F) without derating Storage Temperature: -40°C to +70°C (-40°F to 158°F) Relative Humidity: 5% to 95% non-condensing Altitude: Up to 1000m without derating (1% derating per 100m above 1000m) Vibration: 1.0G maximum (5-200 Hz) Pollution Degree: 2 according to IEC 60664 Electrical Standards & Approvals Compliance: - CE marked - cULus Listed (UL508C) - RoHS compliant - Complies with EN/IEC 61800-3 (EMC) - Meets EN 55011 Class A (Emissions) - IEC 61800-5-1 (Safety) Physical Dimensions Height: 247 mm (9.72 in) Width: 140 mm (5.51 in) Depth: 177 mm (6.97 in) Weight: Approximately 3.2 kg (7.05 lb)
Key Technical Specifications: Parameter Description / Value Product Code ACH550-01-06A9-4 Product Type HVAC Variable Frequency Drive (VFD) / AC Drive Rated Power 3.0 kW (4 HP) Output Current 6.9 A (at 400V, continuous duty) Supply Voltage 3-phase, 380 - 480 V AC (±10%), 50/60 Hz Output Voltage 0 - Supply Voltage (Uin) Output Frequency 0.1 - 500 Hz (typical HVAC range: 0.1 - 120 Hz) Control Method Sensorless Flux Vector Control (FVC): Delivers precise speed and torque control for superior performance in variable torque (fan/pump) applications. Enclosure IP20 / UL Type 1 (Open Chassis). Must be installed in a proper control cabinet to provide protection against dust, moisture, and physical contact. Frame Size R1 Key HVAC Features - Adaptive Programming (AP): Intuitive setup via plain-language questions, simplifying commissioning. - Energy Optimizer: Automatically minimizes motor and drive losses for maximum energy efficiency. - Dedicated Application Macros: Pre-programmed for common HVAC functions (Pump, Fan, HVAC). - Dual PID Controllers: With cascade control, sleep/wake functions, and PID autotune for precise pressure, flow, or temperature regulation. - Flying Start: Enables smooth connection to a spinning motor. - Flexible I/O: 4 Digital Inputs, 2 Analog Inputs (configurable as 0-10V or 0/4-20mA), 1 Analog Output, 2 Relay Outputs. - Motor Thermal Protection: Includes I²t model and direct PTC thermistor input. Built-in Communication - BACnet MS/TP: Native integration with Building Automation and Control Networks (BACnet). - Modbus RTU (RS-485): Standard for industrial and building management systems. - Status LED: Flashing LED for visual indication of drive status and fault codes. Motor & Drive Protection Comprehensive protection including: overcurrent, overvoltage, undervoltage, ground fault, short circuit, input/output phase loss, motor overload (I²t), and stall prevention. Cooling Method Convection cooling (fanless) for Frame Size R1, ensuring silent operation ideal for mechanical rooms. Ambient Conditions Operating Temperature: -10°C to +50°C (14°F to 122°F) without derating. Full rated current up to +40°C. Storage: -40°C to +70°C. Max humidity: 95% non-condensing. Standards & Approvals CE, cULus Listed, RoHS compliant. Meets key global standards for HVAC equipment.
Key Technical Specifications: Parameter Description / Value Product Code ACH550-01-05A6-4 Product Type HVAC Variable Frequency Drive (VFD) / AC Drive Rated Power 2.2 kW (3 HP) Output Current 5.6 A (at 400V, continuous duty) Supply Voltage 3-phase, 380 - 480 V AC (±10%), 50/60 Hz Output Voltage 0 - Supply Voltage (Uin) Output Frequency 0.1 - 500 Hz (standard HVAC motor: 0.1 - 120 Hz) Control Method Sensorless Flux Vector Control (FVC): Provides excellent speed and torque control across the entire speed range, crucial for pump and fan applications. Enclosure IP20 / UL Type 1 (Open Chassis). Must be installed inside a suitable control panel or enclosure for protection against dust and moisture. Frame Size R1 Key HVAC Features - Adaptive Programming (AP): User-friendly setup with plain-language questions. - Energy Optimizer: Automatically minimizes motor losses to achieve maximum energy savings. - Pump & Fan Control Macros: Pre-configured for quick setup of constant pressure, constant flow, or temperature control. - PID Controllers: Dual PID controllers with cascade control and PID sleep/wake-up functions. - Flying Start: Can smoothly connect to a rotating motor. - Multiple I/O: 4 Digital Inputs, 2 Analog Inputs (voltage/current), 1 Analog Output, 2 Relay Outputs. - Advanced Motor Thermal Protection: Includes both I²t and PTC thermistor inputs. Built-in Communication - BACnet MS/TP: Native BACnet Building Automation Controller interface. - Modbus RTU (RS-485): Standard industrial protocol. - Flashing LED: Indicates drive status and fault codes. Motor & Drive Protection Motor thermal (I²t), overcurrent, overvoltage, undervoltage, ground fault, short circuit, phase loss, and motor stall protection. Cooling Method Convection cooling (fanless) for Frame Size R1, ensuring silent operation. Ambient Conditions Operating Temperature: -10°C to +50°C (14°F to 122°F) without derating. Up to +40°C with full rated current. Storage: -40°C to +70°C. Max humidity: 95% (non-condensing). Standards & Approvals CE, cULus Listed, RoHS compliant. Designed to meet global HVAC standards.
Key Technical Specifications: Parameter Description / Value Product Code ACS550-U1-045A-4 Product Type Variable Frequency Drive (VFD), AC Drive, Inverter Rating 22 kW (30 HP) Output Current 45 A (at 400V, continuous duty) Supply Voltage 3-phase, 380 - 480 V AC (±10%), 50/60 Hz Output Voltage 0 - Supply Voltage (Uin) Output Frequency 0 - 500 Hz (standard motor: 0 - 250 Hz) Control Methods Scalar Control (Volts/Hertz - V/Hz): Pre-programmed curves. Flux Vector Control (FVC): Sensorless vector control for improved low-speed torque and speed accuracy. Enclosure IP20 / UL Type 1 (Open Chassis). Requires installation in a suitable control cabinet for protection. Frame Size R4 Key Features - Flying Start: Can catch a rotating motor. - Built-in PID Controller: For process control (e.g., pressure, flow). - Multiple I/O: Digital & Analog Inputs/Outputs, Relay outputs. - ABB Drive Panel Compatibility (Optional): For control and monitoring. - Standard Modbus RTU (RS-485): For fieldbus communication. - Advanced Application Macros: Pre-set parameter groups for quick setup (e.g., Pump/Fan, 3-Wire Control). - DC Bus Connection: Allows common DC bus for multi-drive systems. Motor Control & Protection Motor thermal protection, overcurrent, overvoltage, undervoltage, ground fault, short circuit, and motor stall protection. Cooling Method Forced air cooling (internal fan). Ambient Conditions Operating Temperature: -15°C to +50°C (59°F to 122°F) without derating. Max humidity: 95% (non-condensing). Standards & Approvals CE, UL, cUL
Specifications Electrical Ratings Input Voltage: 380-480V AC (±10%), 3-phase, 50/60 Hz Output Power: 22 kW (30 HP) at 480V Output Current: 45.0 A continuous (40°C ambient) Overload Capacity: 110% for 1 minute every 10 minutes Output Frequency: 0-500 Hz Control Methods: V/Hz, Sensorless Vector, Flux Optimization Physical Characteristics Enclosure: IP21 (indoor, finger-safe) Dimensions: ~450 × 220 × 240 mm Weight: Approximately 16 kg Cooling: Forced-air with temperature-controlled fan Ambient Temperature: 0°C to +40°C (full rating), up to +50°C with derating Altitude: ≤1000 m without derating Control & I/O Configuration Standard I/O Digital Inputs: 5 programmable (24V DC) Digital Outputs: 3 (2 relay, 1 transistor) Analog Inputs: 2 (0-10V/0-20mA) Analog Outputs: 2 (0-20mA) PTC Input: Motor temperature monitoring
Specifications Electrical Ratings Input Voltage: 380-480V AC (±10%), 3-phase, 50/60 Hz Output Power: 22 kW (30 HP) at 480V Output Current: 45.0 A continuous (40°C ambient) Overload Capacity: 110% for 1 minute every 10 minutes Output Frequency Range: 0-500 Hz Control Methods: V/Hz, Open/Closed Loop Vector, Direct Torque Control (DTC) Physical Characteristics Enclosure: IP21 (indoor industrial) Dimensions: ~450 × 220 × 240 mm (H×W×D) Weight: Approx. 16 kg Cooling: Intelligent forced-air with temperature monitoring Ambient Temperature: -15°C to +50°C (derating above +40°C) Relative Humidity: 5-95% non-condensing Altitude: Up to 1000 m without derating Compressor Management: Screw/scroll compressor protection Oil management timers Anti-recycle and minimum off timers Load/unload sequencing Energy Management Energy Optimizer: Reduces motor losses by up to 40% Adaptive Control: Self-tuning PID for varying system conditions Power Factor: >0.98 displacement factor Harmonic Mitigation: Built-in DC choke (optional) Peak Demand Management: Power limiting function Control & Connectivity I/O Configuration Digital Inputs: 6 programmable (24V DC, optical isolation) Digital Outputs: 4 (2 relay, 2 transistor) Analog Inputs: 3 (0-10V/0-20mA/PT1000, 14-bit resolution) Analog Outputs: 2 (0-20mA/4-20mA) Thermistor Inputs: 2 (PTC/KTY)
Specifications Electrical Ratings Input Voltage: 200-240V AC (±10%), 3-phase, 50/60 Hz Output Power: 18.5 kW (25 HP) at 240V Output Current: 45.0 A continuous (40°C ambient) Overload Capacity: 110% for 1 minute every 10 minutes Output Frequency: 0-250 Hz (standard), 0-500 Hz (optional) Physical Characteristics Enclosure: IP21 (indoor use, protected against dripping water) Dimensions: ~450 × 220 × 240 mm (H×W×D) Weight: Approx. 15 kg Cooling: Forced air with temperature-controlled fan Ambient Temperature: 0°C to +40°C (full rating), up to +50°C with deratin Control & I/O Configuration Standard I/O Digital Inputs: 5 programmable (24V DC) Digital Outputs: 3 programmable (2 relay, 1 transistor) Analog Inputs: 2 (0-10V/0-20mA, 12-bit resolution) Analog Outputs: 2 (0-20mA) PTC Input: For motor temperature monitoring
Specifications Parameter Specification Series ACS310 (Material Handling & General Purpose) Typical Power 4.0 kW (5 HP) Common Voltage 400-480V AC, 3-phase (also available in 200-240V versions) Current Rating ~9.8 A (at 400V) Enclosure Options IP21 / IP55 (depends on model suffix) Control Method Direct Torque Control (DTC) or V/Hz Core Features Application-Optimized Material Handling Macros: Pre-programmed for conveyors, cranes, hoists High Starting Torque: Up to 180% for demanding starts S-curve Acceleration: Smooth ramp-up/down for material transport Torque Proving: Ensures adequate torque before load release Technical Capabilities Built-in Modbus RTU (RS-485 standard) Enhanced I/O Configuration: 3 digital inputs (24V DC) 2 analog inputs (0-10V/0-20mA) 2 relay outputs 1 analog output (0-20mA) Integrated Brake Chopper for dynamic braking Flying Start: Can start into rotating motors PID Controller: Built-in for process control Protection & Safety Motor Protection: Thermal (I²t), phase loss, ground fault, stall prevention Drive Protection: Overcurrent, overvoltage, short circuit, overtemperature Safe Torque Off (STO): Optional safety function EMC Compliance: Built-in RFI filter (Category C3 standard) Typical Applications Conveyor Systems: Belt conveyors, roller conveyors, assembly lines Material Handling: Cranes, hoists, elevators, lifting equipment Packaging Machinery: Wrappers, fillers, labelers Machine Tools: Lathes, mills, drills Industrial Automation: Production lines, positioning systems
Specifications Input Power: 200-240V AC (±10%), 1-phase, 50/60 Hz Output Power: 2.2 kW (3 HP) at 240V Output Current: 9.0 A continuous Overload Capacity: 150% for 60 seconds Enclosure: IP21 (indoor industrial use) Dimensions: 210 × 90 × 165 mm (H×W×D) Weight: ~2.3 kg Cooling: Forced air (integrated fan) Key Features High Starting Torque: Up to 180% for demanding starts Material Handling Macros: Pre-programmed for conveyors, cranes, hoists Built-in Modbus RTU: RS-485 communication standard Enhanced I/O: 3 digital inputs 2 analog inputs (0-10V/0-20mA) 2 relay outputs 1 analog output (0-20mA) Brake Chopper: Integrated for dynamic braking Flying Start: Can start into rotating motor Application Focus Primary Applications: Conveyor belts and transport systems Material handling equipment Hoists and lifting devices Packaging machinery Machine tools and positioning systems
Specifications Input: 200–240V AC, 1-phase, 50/60 Hz Output: 0.55 kW (0.75 hp) at 240V, 2.8 A Enclosure: IP21 (finger-safe, drip protection) Dimensions: 152 × 70 × 142 mm (H×W×D) Weight: ~1.5 kg Cooling: Natural convection (fanless) 4. Core Features Built-in Modbus RTU (RS-485 interface) Basic I/O Configuration: 2 digital inputs (24V DC) 1 analog input (0-10V/0-20mA selectable) 1 relay output (250V AC, 2A) 1 analog output (0-20mA) Integrated Control Panel: Includes speed potentiometer Pre-programmed Application Macros: Pump, Fan, Conveyor Basic PID Controller for simple closed-loop control 5. Motor & Protection Features Motor Protection: Thermal overload, short circuit, phase loss Drive Protection: Over/under voltage, overcurrent, overtemperature Safe Stop Capability: Compatible with external safety circuits 6. Typical Applications Small ventilation fans Low-power circulating pumps Light-duty conveyors Packaging equipment Laboratory devices OEM machinery