PRODUCT
PICTURE
BRAND
DESCRIBE
STOCK
DOWNLOAD
Technical Specifications Parameter Specification Part Number / Model 1SBL143001R8110 Product Type Power Contactor Series / Family AL9 series Control / Coil Voltage 24 V DC Rated Operational Voltage (Main Circuit) Up to 690 V AC Number of Poles 3 main poles (3P) Main Contacts 3 Normally Open (3 NO) Auxiliary Contacts 1 Normally Open (1 NO) Rated Operational Current (AC‑3) 9 A (typical motor control duty) Rated Operational Current (AC‑1) ~25 A (general load) Rated Operational Power (AC‑3) ~2.2 kW at 220–240 V AC; ~4 kW at 380–400 V AC; ~5.5 kW at 500–690 V AC Rated Insulation Voltage (Ui) 1000 V Rated Impulse Withstand Voltage (Uimp) 8 kV Control Circuit Type DC operated with solid core magnetic coil Auxiliary / Add‑on Blocks Front and side‑mounted auxiliary contact blocks available Mounting Panel / block contactor mount Terminal Type Screw terminals Ambient Operating Temperature –40 °C to +55 °C Protection Degree IP20 Weight ~0.52 kg Dimensions ~44 × 78 × 97 mm (W × H × D)
Technical Specifications Parameter Specification Part / Model ABB AL9‑30‑10 220 V DC Contactor (1SBL143001R8810) Product Type 3‑Pole Power Contactor Series / Family AL9 Series Control / Coil Voltage 220 V DC Number of Main Contacts 3 Normally‑Open (3 NO) Auxiliary Contacts 1 Normally‑Open (1 NO) Rated Operational Voltage (Main Circuit) Up to 690 V AC Rated Operational Current AC‑1 ~25 A Rated Operational Current AC‑3 ~9 A Rated Operational Power AC‑3 ~4 kW (at 400 V AC) Rated Insulation Voltage Up to 690 V (IEC standards) Terminal Type Screw terminals Control Frequency DC coil operation Mounting Panel / DIN rail compatible Application Motor control, load switching, general power circuits
Technical Specifications Parameter Specification Part Number / Model 1SDA068057R1 Product Type Molded Case Circuit Breaker (MCCB) Series / Family SACE Tmax XT3N Trip Unit Type Thermo‑magnetic (TMD), adjustable short‑circuit range 160–1600 A Number of Poles 3 poles (3P) Rated Current (In) 160 A Overload Setting Range ~112–160 A Instantaneous Trip Setting (Short‑Circuit) 1600 A (fixed) Rated Operational Voltage (Ue) Up to 690 V AC / 500 V DC Rated Insulation Voltage (Ui) ~800–1000 V Rated Impulse Withstand Voltage (Uimp) 8 kV Rated Ultimate Short‑Circuit Breaking Capacity (Icu) ~36 kA at 400 V AC Rated Service Short‑Circuit Breaking Capacity (Ics) Similar to Icu at common voltages Terminal Connection Front bolt terminals Connection Capacity Cable/busbar compatible Mechanical Durability ~25,000 operations Electrical Endurance ~8,000 operations Degree of Protection IP20 Standards Compliance IEC 60947‑2 Mounting Fixed installation with front access
Technical Specifications Parameter Specification Part Number / Model 1SDA067032R1 Product Molded Case Circuit Breaker (MCCB) Series / Family Tmax XT2N Trip Unit Type Thermomagnetic (TMD), adjustable 20–300 A Number of Poles 4 Poles (4P) Rated Operational Current (In) 20 A (trip setting) Rated Uninterrupted Current (Iu) 160 A Adjustment Range (Thermal / Magnetic) 14–20 A thermal; magnetic up to 300 A Rated Operational Voltage (Ue) up to 690 V AC / 500 V DC Rated Insulation Voltage (Ui) 1000 V Rated Impulse Withstand Voltage (Uimp) 8 kV Short‑Circuit Breaking Capacity (Icu) Up to 65 kA at lower AC voltages; 36 kA at 380–440 V AC; 10 kA at 690 V AC Rated Service Breaking Capacity (Ics) Same as Icu ratings Terminal Type Front bolt terminals Connection Capacity Cable/busbar compatible (e.g., 32.5–100 mm²) Mechanical Durability ~25,000 operations Electrical Endurance ~8,000 operations Degree of Protection IP20 Standards Compliance IEC 60947‑2 Typical Weight ~1.4–1.6 kg Typical Width ~120 mm
Technical Specifications Parameter Specification Part Number / Model 1SDA067049R1 Product Type Molded Case Circuit Breaker (MCCB) Series / Family Tmax XT2N Trip Unit / Release Type Magnetic only (MA / MF) Number of Poles 3 poles (3P) Rated Current (In) 20 A Frame / Uninterrupted Current (Iu) 160 A Adjustable Magnetic Trip Range (Ii / Im) 120 A … 280 A Rated Operational Voltage (Ue) Up to 690 V AC / 500 V DC Rated Insulation Voltage (Ui) 1000 V Rated Impulse Withstand Voltage (Uimp) 8 kV Rated Service Short‑Circuit Breaking Capacity (Ics) Up to 65 kA at lower AC voltages; 36 kA at 380–440 V AC; 10 kA at 690 V AC Rated Ultimate Short‑Circuit Breaking Capacity (Icu) Same as Ics across rated voltages Terminal Type Front bolt terminals Connection Capacity Busbar/cable compatible (e.g., 32.5–100 mm²) Mechanical Durability ~25,000 operations Electrical Endurance ~8,000 operations Standards Compliance IEC 60947‑2 Weight (approx.) ~1.1 kg Dimensions (approx.) Width ~90 mm × Height ~130 mm × Depth ~82.5 mm
Technical Specifications Parameter Specification Part Number / Model 1SDA067048R1 Product Type Molded Case Circuit Breaker (MCCB) Series / Family Tmax XT2N Trip Unit / Release Magnetic (MF) Number of Poles 3 poles (3P) Rated Current (In) 12.5 A Rated Uninterrupted Current (Iu) 160 A Rated Instantaneous Short‑Circuit Setting (Ii) 175 A Rated Operational Voltage (Ue) Up to 690 V AC / 500 V DC Rated Insulation Voltage (Ui) 1000 V Rated Impulse Withstand Voltage (Uimp) 8 kV Rated Service Short‑Circuit Breaking Capacity (Ics) Up to 65 kA at lower AC voltages / 36 kA at 380–440 V AC / 10 kA at 690 V AC Breaking Capacity (Icu) Same as Ics across rated voltages Terminal Type Front terminals (bolt) Connection Capacity Busbar/cable compatible (typically 32.5–100 mm²) Mechanical Durability ~25,000 operations Electrical Endurance ~8,000 operations Standards Compliance IEC 60947‑2 Mounting Fixed installation Typical Dimensions Width ~90 mm; Height ~130 mm; Depth ~82.5 mm Weight (approx.) ~1.1–1.2 kg
Technical Specifications Parameter Specification Part Number / Model 1SDA067047R1 Product Type Molded Case Circuit Breaker (MCCB) Series / Family Tmax XT2N Trip Mechanism / Release Type Magnetic (MF) Number of Poles 3 (3P) Rated Current (In) 8.5 A Rated Frame Current (Iu) 160 A Adjustment Range of Magnetic Release (Im) 120 A Rated Operational Voltage (Ue) up to 690 V AC / 500 V DC Rated Insulation Voltage (Ui) 1000 V Rated Impulse Withstand Voltage (Uimp) 8 kV Rated Short‑Circuit Breaking Capacity (Icu) 36 kA at 400 V AC Rated Service Short‑Circuit Breaking Capacity (Ics) up to 36 kA Terminal Type Front bolt terminals Connection Capacity Cable/busbar connections (32.5–100 mm²) Mechanical Durability ~25,000 operations Electrical Endurance ~8,000 operations Standards Compliance IEC 60947‑2 Degree of Protection IP20 Weight ~1.2–1.4 kg Dimensions (approx.) Width ~90 mm Typical Applications Protection of three‑phase feeders Short‑circuit and overcurrent protection in industrial panels Power distribution systems in industrial and commercial buildings Motor feeder protection and general circuit protection
Technical Specifications Parameter Specification Part Number / Model 1SDA067045R1 Product Type Molded Case Circuit Breaker (MCCB) Series / Family Tmax XT2N Trip Unit / Release Magnetic (MF) Number of Poles 3 (3P) Rated Frame Current (Iu) 160 A Magnetic Trip Setting (Ii) 28 A Rated Operational Voltage (Ue) 690 V AC / 500 V DC Rated Insulation Voltage (Ui) 1000 V Rated Impulse Withstand Voltage (Uimp) 8 kV Rated Short‑Circuit Breaking Capacity (Icu) 65 kA @ 220–240 V AC; 36 kA @ 380–440 V AC; 10 kA @ 690 V AC Rated Service Breaking Capacity (Ics) Same as Icu Terminal Type Front bolt terminals Terminal Screw Torque ~6 N·m Mounting Fixed installation Standards Compliance IEC 60947‑2 Mechanical Durability ~25,000 operations Electrical Endurance ~8,000 operations
Technical Specifications Parameter Specification Product / Model ABB A26‑30‑10 380‑400V AC Contactor Type Three‑pole AC power contactor Series / Family ABB A26 series contactors (block type) Number of Main Contacts 3 Normally Open (3 NO) Auxiliary Contacts 1 Normally Open (1 NO) built‑in Control Coil Voltage (Uc) 380–400 V AC 50 Hz / 400–415 V AC 60 Hz Rated Operational Voltage – Main Circuit Up to 690 V AC Conventional Free‑Air Thermal Current (Ith) ~45 A (at 40 °C free air) Rated Operational Current (AC‑1) ~45 A (690 V AC, 40 °C) Rated Operational Current (AC‑3) ~26 A at 380–440 V AC (typical) Rated Operational Power (AC‑3) ~11 kW at 380–400 V AC Rated Insulation Voltage (Ui) 1000 V (IEC) Rated Impulse Withstand Voltage (Uimp) 8 kV Rated Breaking/Making Capacity (AC‑3) 8× / 10× Ie Short‑Time Withstand Current (Icw) 210–400 A depending on duration Switching Frequency (Electrical) AC‑1: 600 cycles/h; AC‑3: 1200 cycles/h Mechanical Durability ~10,000,000 operations Terminal Type Screw terminals Mounting Panel / DIN‑rail compatible Degree of Protection IP20 Coil Consumption ~3–12 VA holding, with pull‑in values per IEC Application Motor control, power switching, lighting & general loads
Technical Specifications Parameter Specification Part / Model ABB A12‑30‑01 220‑230 V AC Contactor (e.g., 1SBL161001R8001) Product Type Three‑pole AC power contactor Number of Main Contacts 3 Normally Open (3 NO) Auxiliary Contacts 1 (typically NC or configurable) Control Coil Voltage (Uc) 220‑230 V AC (50 Hz) / 230‑240 V AC (60 Hz) Rated Operational Voltage – Main Circuit Up to 690 V AC Conventional Free‑Air Thermal Current (Ith) ~28 A (IEC 60947‑4‑1) Rated Operational Current AC‑1 (Ie) ~27 A @ 690 V (40 °C) Rated Operational Current AC‑3 (Ie) ~12 A @ 220‑240 V AC Rated Operational Power AC‑3 (Pe) ~3 kW @ 220–240 V AC; ~5.5 kW @ 380–415 V AC Rated Operational Current AC‑15 (Ie) ~4 A @ 220‑240 V AC Rated Insulation Voltage (Ui) 1000 V IEC Rated Impulse Withstand Voltage (Uimp) 8 kV Rated Making / Breaking Capacity AC‑3: 10× / 8× Ie Switching Frequency AC‑1: ~600 cycles/hr; AC‑3: ~1200 cycles/hr Mechanical Durability ~10 million operations Coil Consumption ~8 VA holding; ~70–74 VA pull‑in Connection / Terminals Screw terminals for main and control wiring Mounting DIN‑rail / panel mount capable Standards Compliance IEC 60947‑4‑1, IEC 60947‑5‑1 Ambient Operating Temperature Range Typically −40 °C to +55 °C Typical Weight ~0.34 kg Typical Dimensions (approx.) Width ~44 mm, Height ~74 mm, Depth ~74 mm
Technical Specifications Parameter Specification Part Number / Model ABB 1SDA038676R1 Product Type Molded Case Circuit Breaker (MCCB) Series / Family SACE Isomax S5 Trip Unit Type PR212‑P electronic release with LSI (Long‑Time, Short‑Time, Instantaneous) Number of Poles 3 poles (3P) Rated Current (In) 630 A Protection Functions Overload (L), Short‑Time (S), Instantaneous (I) Rated Operational Voltage (Ue) Up to 690 V AC typical Frame / Housing Fixed MCCB with front terminal connections IEC Utilization Category IEC 60947‑2 compliant Settings / Adjustments Adjustable trip parameters via PR212‑P release Auxiliary / Control Electronic trip unit for coordination and protection Mounting Panel / switchgear fixed installation Application Overload and fault protection in power distribution and industrial circuits Typical Accessories Auxiliary contacts, shunt trip, alarm contact modules (optional)
Technical Specifications Parameter Specification Part Number / Model AX09‑30‑01‑81 / 1SBL901074R8101 Product Type AC Power Contactor Series / Family AX series Control Coil Voltage 24 V AC, 50/60 Hz Number of Poles 3 main poles (3P) Main Contacts 3 Normally Open (NO) Auxiliary Contacts 1 Normally Closed (NC) built‑in Rated Operational Voltage (Main Circuit) Up to 690 V AC Rated Operational Current (AC‑1) ~22 A at 690 V AC Rated Operational Current (AC‑3) ~9 A (typical motor control duty) Rated Operational Power (AC‑3) up to ~4–5.5 kW depending on voltage Rated Insulation Voltage (Ui) 690 V (IEC 60947‑4‑1) Rated Frequency 50 / 60 Hz (main & control circuits) Conventional Free‑Air Thermal Current (Ith) 24 A Maximum Breaking Capacity ~250 A at 440 V AC; ~90 A at 690 V AC Switching Frequency (Electrical) AC‑1: 600 cycles/hour; AC‑3: 1200 cycles/hour Switching Frequency (Mechanical) 3600 cycles/hour Short‑time Withstand Current (Icw) ~100 A for 10 s (cold) Terminal Type Screw terminals Mounting DIN‑rail / panel compatible Operating Temperature Range ~‑40 °C to +70 °C Degree of Protection IP20 Dimensions (approx.) Width ~44 mm × Height ~74 mm × Depth ~74 mm Weight (approx.) ~0.33 kg