Industrial Controller
All product are in stock,guaranteed delivery within 3-7 days.
Infinite Innovation, the Future of Industrial Control Systems
Infinite Innovation, the Future of Industrial Control Systems
PRODUCT HOME>>PRODUCT
PRODUCT

PRODUCT

PICTURE

BRAND

DESCRIBE

STOCK

DOWNLOAD

Technical Parameters Product Type: Safety adapter unit Model: TINA 3A Part Number: 2TLA020054R0200 Function: Interfaces two safety contacts to ABB DYNlink system Power Supply Voltage: 24 V DC Current Consumption: Approximately 47 mA Connection Type: 5-pin M12 male connector for DYNlink loop Housing Material: Industrial PVC body Mounting: On device enclosure, with cable entry Protection Class: IP67 Operating Temperature Range: -10 °C to +55 °C Typical Device Compatibility: Emergency stops and mechanical safety switches with two force-guided contacts Application Field: Industrial machinery safety, safety control cabinet installations, and automation safety loops

Technical Parameters Product Type: Contactor Relay Model: NSL44E-88 Order Code: 1SBH103001R8844 / similar NSL44E-88 series coding Number of Poles: 8 poles Typical Contact Arrangement: 4 normally open + 4 normally closed (auxiliary contacts) Control Coil Voltage: 220 V DC Coil Type: DC coil, polarity sensitive Application: Auxiliary and control circuit switching Mounting: Panel or DIN-rail mounting (with accessories) Typical Usage: PLC control interface, automation control circuits, auxiliary signal switching

Technical Parameters General Product Type: Selector switch Model: M2SS2‑11C Actuator Style: Short rotary handle Design: Non‑illuminated selector switch Maintained Positions: 2 (maintained latching) Mounting: Panel mount, 22 mm cut‑out Contact Configuration Auxiliary Contacts: 1 × Normally Open (NO) 1 × Normally Closed (NC) Contact Form: 1NO + 1NC Contact Operation: Changes state with selector position Electrical Ratings Rated Operational Voltage: Up to 300 V AC/DC Rated Insulation Voltage: 300 V Rated Impulse Withstand Voltage: 6 kV Rated Current (AC‑15): Approx. 1 A at 220–240 V AC Rated Current (DC‑13): Approx. 0.3 A at 24–125 V DC Utilization Category: Suitable for control and signal circuits Mechanical Mechanical Life: Approx. 500,000 cycles Actuator Torque / Operation: Designed for positive manual switching Terminal Type: Screw terminal connections Environmental Front Protection Rating: IP66/IP67/IP69K (front — when installed correctly) Terminal Protection Rating: IP20 Operating Ambient Temperature: –25 °C to +70 °C Storage Temperature: –40 °C to +85 °C Pollution Degree: Suitable for industrial environments Physical Dimensions Panel Cut‑out Diameter: 22 mm Approximate Body Size: Standard compact selector switch footprint Weight: Lightweight industrial device Applications Mode selection (e.g., Local/Remote, Auto/Manual) ON/OFF or dual‑state machine control interface Control panel operator stations Industrial automation selecting between control states Logic selection input for PLCs and controllers

Technical Parameters General Product Type: HRC (High‑Rupturing Capacity) fuse link Model / Part Number: OFAFC00GG125 Fuse System: DIN type fuse link Utilization Category: gG (general‑purpose full‑range protection) Rated Current: 125 A Size / Fuse Frame: 00 (NH00) fuse size Approvals / Standards: IEC 60269 fuse standard compliance Typical Application: Overload and short‑circuit protection in low‑voltage power systems Electrical Ratings Rated Current (In): 125 A Rated Voltage (Ur): up to 690 V AC (common rating for gG HRC fuses in this size) Utilization Category (gG): protects both cables and equipment against overload and short‑circuit faults Breaking / Interrupting Capacity: Very high fault clearing capability suitable for industrial distribution levels Rated Power Loss: Typical power loss at rated current is within acceptable limits for this fuse size Mechanical & Physical Fuse Size: NH00 (DIN 00) Body Type: DIN blade fuse link Mounting Method: Installed into a compatible DIN fuse holder or switch‑fuse base Mechanical Construction: Rugged metal and insulating body for reliable operation Weight & Dimensions (Typical): Compact NH00 form factor for space‑efficient installation RS Components Environmental Operating Environment: Suitable for control panels, distribution boards, and industrial switchgear Ambient Temperature: Industrial ambient conditions typical for low‑voltage distribution equipment Applications Main or branch‑circuit protection in industrial and commercial distribution panels Protection of feeders, cables, transformers, and motors Retrofit or replacement in ABB switch‑fuse disconnectors and DIN‑fuse systems Ensures safety and equipment protection in low‑voltage power networks

Technical Parameters General Product Type: Rotary selector switch Model: C2SS2‑10B‑20 Actuator: Short black rotary handle Illumination: Non‑illuminated Function: Maintained (latching) 2‑position switch Panel Mounting Size: 22 mm cut‑out Bezel / Housing Material: Metal bezel with durable plastic body Contact Configuration Auxiliary Contacts: 1 × Normally Open (NO) 1 × Normally Closed (NC) Contact Form: 1NO + 1NC Contact Operation: Changeover when actuator rotates between positions Electrical Ratings Rated Operational Voltage: Suitable for up to 300 V AC/DC Rated Current: AC‑15: Approx. 1 A at 220–240 V AC DC‑13: Approx. 0.3 A at 24–125 V DC Rated Insulation Voltage: Approx. 300 V Rated Impulse Withstand Voltage: Approx. 6 kV Mechanical Operating Life: Approx. 500,000 mechanical operations Terminal Type: Screw terminals Pollution Degree: Suitable for industrial control environments Mechanical Endurance: High for frequent switching Environmental & Protection Front Protection Rating: High dust/water resistance (e.g., IP66/IP67/IP69K) when installed correctly Terminal Protection Rating: IP20 Operating Ambient Temperature: –25 °C to +70 °C (typical industrial range) Storage Temperature: –40 °C to +85 °C Applications Mode selection (e.g., local/remote, auto/manual) On/Off or dual‑state control input Operator panel interfaces in automation systems Industrial machinery control stations Control logic and signaling circuits

Technical Parameters General Product Type: Auxiliary auxiliary contact block for MCCBs Model / Accessory: AUX‑C 3Q1SY‑Cabled 250 VAC/DC (T1‑T3) Suitable For: ABB SACE Tmax T series circuit breakers — frames T1, T2, T3 Mounting: Side/slot accessory that installs in the breaker’s accessory slot Connection: Pre‑wired cable for remote signaling Contact Configuration Changeover Contacts (SPDT): 3 changeover (3Q) for breaker position feedback (open/closed) Trip Indication Contact: 1 changeover contact (1SY) dedicated for signaling a trip (release) event Total Contacts: 4 changeover contacts Electrical Ratings Rated Operational Voltage: up to 250 V AC/DC Utilization Categories: Suitable for low‑power control and signaling circuits AC‑15 up to ~4 A @ 250 V AC AC‑12 up to ~6 A @ 250 V AC DC‑12 up to ~0.3 A @ 250 V DC DC‑14 up to ~0.03 A @ 250 V DC (Typical auxiliary contact ratings for 250 V AC/DC control signaling) ABB Electrification Mechanical Terminal Wiring: Pre‑wired with cable leads for easy panel connection Contact Type: Changeover (single‑pole double‑throw) contacts Mechanical Life: High cycle life suitable for frequent status switching Mounting Position: Installed in the accessory slot of compatible breakers Environmental Operating Temperature: Industrial ambient range suitable for electrical panels Protection Rating: IP20 at connections when installed (panel dependent) Pollution Degree: Industrial environment Applications Remote indication of breaker ON / OFF status Trip (fault) signaling to PLCs, SCADA, alarms, or control circuits Integration in motor control centers and distribution panels Status feedback for automation and safety interlocks

Technical Parameters General Product Type: Safety interface / DYNlink adapter Model / Ordering Code: 2TLA020054R1210 (TINA 10A v2) Function: Adapts OSSD safety outputs to DYNlink safety loop signals Application Category: Machine safety, safety sensor integration Protection Rating: IP67 (splash/dust protection suitable for industrial environments) Housing Material: Industrial‑grade rugged plastic Approx. Weight: ~0.03 kg Approx. Dimensions: ~77 mm (length) × ~36 mm (width) × ~14 mm (height) Connectors / Interface DYNlink Loop Connector: M12‑5 male OSSD Device Connector: M12‑8 female Connector Standard: Circular M12 industrial connectors Electrical / Signal Supply Voltage: Typical 24 V DC for adaptor operation (via safety system supply) Total Current Consumption: Nominal ~25 mA; Max ~35 mA DYNlink Input Signal Voltage Range: ~8 – 15 V RMS (signal link) DYNlink Output Signal Voltage Range: ~8 – 15 V RMS OSSD Input Current per Channel: ~10 mA typical Output Contact / Information Output: Signal high ~22 V DC; low < 2 V DC; max 10 mA Performance Signal Delay: < 120 µs between input and output DYNlink signals Duty: Designed for continuous safety system integration with quick response Signal Compatibility: Interfaces optical safety components’ OSSD outputs with DYNlink safety loops Environmental Operating Temperature: ~‑10 °C to +55 °C Storage Temperature: ~‑10 °C to +55 °C Humidity Range: 35 % to 85 % (no icing or condensation) Protection Level: IP67 rated enclosure for dust/water resistance Safety & Standards Intended for integration in machine safety control circuits Provides secure adaptation of safety sensor outputs for use with DYNlink‑based safety controllers Robust industrial connectors and rated protections for reliable field wiring Applications Machine safety systems requiring connection of optical safety sensors to safety controllers Interfacing OSSD outputs (e.g., from light curtains, safety scanners, electro‑sensitive protective equipment) to DYNlink networks Integration with PLC safety modules and safety bus loops in automated equipment Safety signal conditioning in manufacturing and process automation panels

Technical Parameters General Product Type: AC magnetic contactor Model: AX18‑30‑01‑80 Series: AX family of contactors Poles: 3 main power poles Auxiliary Contacts: 0 Normally Open (NO), 1 Normally Closed (NC) Electrical Ratings Rated Operational Current (AC‑3): ~18 A (typical for this size) Rated Operational Current (AC‑1): Higher capacity for non‑motor loads Rated Insulation Voltage (Ui): ~690 V AC Rated Operational Voltage: Up to ~690 V AC (main circuit) Control (Coil) Voltage: Variant ‑80 typically indicates coil rated for 220–230 V AC at 50/60 Hz Other coil voltages may be available in the same series (e.g., 24 V, 110 V, 380–415 V AC) Control / Coil Coil Type: AC operated electromagnetic Coil Frequency: Compatible with 50 Hz and 60 Hz supplies Coil Operating Range: Designed to operate reliably at the rated coil voltage with standard tolerances Performance Motor Rated Operational Power (AC‑3): Suitable for motors in the range typical for ~18 A contactor frame (e.g., ~4 kW at 400 V AC) Switching Capacity: Appropriate for general AC loads and motor circuits Electrical Endurance: Designed for frequent switching operations Mechanical Endurance: High life expectancy under normal use Mechanical & Installation Mounting: DIN‑rail or screw panel mounting Terminal Type: Screw clamp terminals for main and auxiliary circuits Contact Material: Industrial‑grade alloy for reliable switching Compact Construction: Saves panel space Environmental Operating Ambient Temperature: Standard industrial range (e.g., −25 °C to +70 °C) Storage Temperature: Typical extended ambient range Pollution Degree: Suitable for industrial environments Standards & Compliance Designed to meet common low‑voltage control and switching equipment standards (IEC/EN 60947 series) Applications Control of three‑phase motors in starters and automation systems General AC load switching in control panels Industrial control and power distribution circuits Integration with overload relays and control logic assemblies

Technical Parameters General Product Type: Contactor relay / control relay Model Family: NSL series (NSL80E) Specific Variant: NSL80E‑88 (DC coil version typically for 220 V DC) Contact Arrangement: 8 × Normally Open (8NO) contacts Number of Poles: 8 poles (control contacts) Mounting: Panel or DIN rail with adapter (depending on panel design) Control / Coil Control Coil Type: DC coil (e.g., 220 V DC) Control Circuit Voltage: Matches the coil variant (e.g., 220 V DC input) Coil Consumption: Industrial relay type coil (designed for continuous energization) Electrical Ratings Rated Operational Voltage (Auxiliary circuits): Suitable for control and signal levels (up to typical industrial control voltages, e.g., 250 V) Rated Insulation Voltage: High insulation for auxiliary circuits Conventional Free‑air Thermal Current (Ith): ~16 A for auxiliary contacts Rated Operational Current AC‑15: Typical rated control load as per industrial standards (e.g., 4 A at 220–240 V AC, varies by contact standard) Operating Frequency: DC coil, contact switching handles AC/DC loads compatible with category ratings Switching Duty: Suitable for frequent control switching use Contact & Performance Contact Configuration: 8 independent NO contacts Contact Material: Industrial silver alloy Mechanical Durability: Designed for millions of operations under control conditions Electrical Durability: Rated for frequent switching of auxiliary circuits Mechanical & Terminals Terminal Type: Screw terminals Connection Capacity: Typical industrial panel wiring sizes Housing: Compact relay package with standard width and depth for NSL series devices Environmental Operating Ambient Temperature: Standard industrial ambient range (e.g., −40 °C to +55 °C near contactor for continuous operation when energized at 0.85…1.1×Uc) Storage Temperature: Extended ambient range (e.g., −60 °C to +80 °C) Pollution Degree: Industrial control environments Altitude Rating: Up to typical industrial elevations (~3000 m) without derating Standards & Compliance Meets international industrial control relay standards for insulation, mechanical endurance, and contact duty. Applications Switching of control and auxiliary circuits Interface to PLC or automation systems Panel logic control in industrial equipment Multiple contact outputs for status signaling Control panel interlock and sequencing logic

Technical Parameters General Product Type: Pilot device enclosure / control station housing Model: MEP4‑0 Seats / Positions: 4 × 22 mm operator holes Series: Modular pilot device enclosures Mechanical & Construction Housing Material: Heavy-duty polycarbonate plastic Color: Dark gray (cover) / light gray (body) Mounting: Panel mount; face designed for 22 mm operator cut-outs Included Hardware: Stainless steel mounting screws Dimensions & Weight Width: Approx. 221 mm Height: Approx. 61 mm Depth: Approx. 75 mm Weight: Approx. 0.309 kg Operator Cut-out Size: 22 mm diameter per hole Protection & Environmental Ingress Protection: Front IP66 rated for dust/water resistance Operating Temperature Range: –25 °C to +70 °C Storage Temperature: –40 °C to +85 °C Pollution Degree: Suitable for industrial environments Compatibility & Accessories Compatible Operators: Pushbuttons, selector switches, indicator lights, joysticks, and other 22 mm modular ABB pilot devices Contact Blocks: Snap-on or rear mount auxiliary contact blocks and lamp blocks (ordered separately) Cable Entry: Knockout options for wiring feed-through Applications Industrial control stations and operator panels Machine/equipment interface modules Automation system input assemblies Local control stations in manufacturing and power distribution cabinets OEM electrical enclosures and custom control blocks

Technical Parameters General Product Type: Illuminated pilot light Model: CL2‑523C Series: CL2 compact pilot devices Lens Color: Clear / transparent Indicator Type: LED illumination Panel Mounting Size: 30 mm nominal cut‑out Electrical Rated Operational Voltage: 230 V AC Rated Frequency: 50 Hz / 60 Hz Current Consumption: ~17 mA Light Source: Integrated LED (no replaceable bulb) Base Type: BA9s‑style mount (LED lamp integrated) Rated Insulation Voltage: Suitable for low‑voltage control circuits Mechanical & Connection Terminal Type: Screw clamp terminals Connecting Capacity: Flexible with ferrule: 0.75 … 2.5 mm² Solid: 0.75 … 2.5 mm² Wire Stripping Length: ~8 mm Tightening Torque: ~0.9 N·m Dimensions (approx): Width: ~30 mm Depth: ~52 mm Net Weight: ~0.018 kg Environmental & Protection Operating Temperature Range: –25 °C to +70 °C Storage Temperature Range: –40 °C to +85 °C Ingress Protection: Front: IP66 / IP67 / IP69K (high dust & water resistance) Terminals: IP20 NEMA / Enclosure Ratings: NEMA 1 / 3R / 4 / 4X / 12 / 13 (when correctly installed in a panel) Pollution Degree: Industrial environments Applications Visual status indication in control panels and switchboards Fault or power‑on indication for machines and equipment OEM electrical panels and automation systems Status signaling in manufacturing and process controls

Technical Parameters General Product Type: Current monitoring relay (single‑phase) Model: CM‑SRS.12S Mounting: DIN rail (IEC 60715) Terminal Type: Screw connection terminals Output Contact: 1 × changeover (SPDT) contact Contact Rating: Suitable for control and signal loads (e.g., up to ~250 V, typical industrial relay ratings) Monitoring & Function Monitored Current Type: AC and DC single‑phase Detection Function: Over‑ and under‑current detection based on set thresholds Output Contact Action: Changes state when monitored current exceeds or falls below the configured threshold Adjustability: Threshold and hysteresis adjustable for precise current supervision Indication: Relay output state indicates monitoring status Coil / Supply Control Supply Voltage: Typically supplied in variants such as 24 – 240 V AC/DC depending on version Voltage Type: Compatible with AC/DC supply types (model dependent) Electrical Ratings Output Contact Capacity: Suitable for switching control circuits (e.g., up to ~4 A at 250 V AC) Relay Contact Configuration: SPDT (Single Pole Double Throw) Mechanical & Physical Width: ~22.5 mm (1 module wide) Height: ~85.6 mm Depth: ~103.7 mm Housing: DIN‑rail industrial enclosure Mounting Rail: 35 mm DIN rail Performance & Response Response Time: Fast response to current changes (typically < 100 ms) Hysteresis: Adjustable to prevent chattering around threshold point Accuracy: Suitable for precise current monitoring in control systems Environmental Operating Ambient Temperature: Standard industrial ambient range Pollution Degree: Industrial environments Protection Rating: IP20 at terminal level (front/protection depends on panel installation) Applications Current monitoring in industrial control panels Motor supervision and protection circuits Alarm signalling for current thresholds Automation control logic (PLC/relay inputs) Detection of undercurrent / overcurrent conditions

SERVICE HOTLINE Grace +86 13600179521
Mail info@hongkongeasy.com jilineasyyi@outlook.com ADDRESS Unit 12, 20th Floor, Good View Commercial Centre, 2-16 Garden Street, Mong Kok, Hong Kong
Q Q: 615739355
吉林易择科技技术发展有限公司 吉ICP备2024020526号-1
js
2.095897s