Key Specifications General Product Type: Industrial contactor Series: ABB AF52 Model/Part Number: AF52‑30‑00‑13 Poles: 3 (three main poles) Main Contacts: 3 Normally Open (3NO) Intended Use: Motor control, power switching in industrial systems Control Coil Coil Type: Electronic AC/DC coil Control Voltage Range: 100–250 V AC/DC Frequency: 50/60 Hz Current and Load Ratings Rated Operational Current (AC‑3): Approximately 53 A @ 400 V AC (motor load) Rated Power Ratings (AC‑3): – ~15 kW @ 230 V AC – ~22 kW @ 400 V AC – ~30 kW @ 415–690 V AC General Power Switching (AC‑1): Up to ~100 A UL/CSA Motor Ratings: – ~20–50 hp depending on supply voltage Electrical Characteristics Rated Insulation Voltage: ~690 V (IEC) / ~600 V (UL) Rated Impulse Withstand Voltage: ~6 kV Conventional Thermal Current: ~100 A @ 690 V (AC‑1) Maximum Breaking/Make Capacity: Suitable for industrial switching Mechanical & Durability Operating Cycles: ~10,000,000 mechanical operations Electrical Switching Frequency: – AC‑1: ~600 cycles/hour – AC‑3: ~1200 cycles/hour Terminal Type: Screw terminals Connection: Double connector / DIN‑rail or panel mount Operating Temperature: wide ambient range Physical Dimensions (approx.): Height ~125.5 mm × Width ~55 mm × Depth ~111 mm Enclosure Protection: IP10/IP20 (main/coil) Mechanical Construction: Rugged for industrial use Standards & Compliance IEC/EN 60947‑4‑1 (contactor standard) UL 60947‑4‑1, CSA certified CE and RoHS compliant
Key Specifications General Product Type: Thermal overload relay Model: TA25DU3.1M Poles: 3 Overload Setting Range: 2.2–3.1 A Trip Class: 10A Reset: Manual or automatic selectable Auxiliary Contacts: 1 NO + 1 NC Electrical Ratings Rated Operational Voltage (Main): up to 690 V AC Rated Insulation Voltage (Ui): 690 V Rated Frequency: 50/60 Hz Auxiliary Contact Ratings: Suitable for typical control circuits Mechanical / Installation Mounting: Direct attachment to compatible ABB contactors Terminals: Screw type Degree of Protection: IP20 (housing), IP10 (main terminals) Dimensions: ~80 × 44 × 94 mm (H×W×D) Operating Temperature: –25 °C to +55 °C Standards & Compliance IEC/EN 60947‑4‑1 UL and CSA recognized
Key Specifications General Product Type: Three‑phase soft starter Series: PSR (compact range) Model: PSR37‑600‑11 Rated Operational Current: 37 A Weight: ~1.1 kg Voltage & Frequency Main Supply Voltage: 208–600 V AC Control Supply Voltage: 24 V AC/DC Frequency: 50/60 Hz Motor & Performance Soft start/stop via voltage ramp control Built‑in bypass for full‑speed operation Run and TOR signal relay outputs Adjustable start time: 1–20 s Adjustable stop time: 0–20 s Typical motor ratings: ~7.5 kW @ 230 V, ~18.5 kW @ 400 V, ~22 kW @ 500 V Typical start frequency: up to 100 starts/hour Protection & Features Class 10 overload protection Reduces mechanical and electrical stress Compact design for small motors and control panels Mechanical & Environmental Enclosure Protection: IP10/IP20 (installation dependent) Mounting: In‑line or DIN‑rail with accessories Terminals: Screw Operating Temperature: −25 °C to +60 °C Dimensions: 153 × 54 × 187 mm (L×W×H) Applications Pumps, fans, compressors, conveyors, and small industrial motors Motor control panels requiring reduced inrush and smoother start/stop
Key Specifications General Product Type: Three‑phase monitoring relay Model: CM‑MPS.21S ABB Part Number: 1SVR730885R3300 Function: Phase failure, phase sequence, over‑ & undervoltage, phase unbalance, interrupted neutral monitoring Mounting: DIN‑rail TH35/TH35‑7.5 Electrical Rated Control Supply Voltage / Measuring Voltage: 180 – 280 V AC, 50/60 Hz Output Contacts: 2 changeover (2 c/o / SPDT) Contact Rating: 250 V AC / 4 A Rated Operational Currents: AC‑12: ~4 A @ 230 V AC‑15: ~3 A @ 230 V DC‑12: ~4 A @ 24 V DC‑13: ~2 A @ 24 V Minimum Switch Capacity: 24 V / 10 mA Monitoring & Timing Adjustable Trip Delay: Instantaneous or 0.1 – 30 s Start‑up Delay: ~0.2 s Adjustable Threshold Values for Phase Conditions Mechanical Terminal Type: Screw / cage connection Mounting Position: Any Connecting Capacity (wire size): flexible up to ~2.5 mm², rigid up to ~4 mm² Overvoltage Category: III Pollution Degree: 3 Physical Width: ~22.5 mm Height: ~85.6 mm Depth: ~103.7 mm Weight: ~0.146 kg Environmental & Standards Operating Temperature: approx. −25 °C to +60 °C Degree of Protection: Housing IP50, terminals IP20 Certifications: IEC/EN 60255‑1, IEC/EN 61000 series EMC, CAN/CSA C22.2 No.14, UL508, CE, RoHS compliant
Key Specifications General Product Type: Molded Case Circuit Breaker (MCCB) Series: ABB Tmax T2 Poles: 3 Trip Unit: Thermal‑magnetic (TMD) Connection: Fixed front terminals (FF) Frame Size: 160 (T2S160) Adjustable Trip Setting Range: 100–1000 A Electrical Ratings Rated Operational Voltage: up to 690 V AC Rated Insulation Voltage (Ui): ~800 V Rated Impulse Withstand Voltage (Uimp): 8 kV Rated Uninterrupted Current (Iu): 160 A Standards: IEC 60947‑2 Short‑Circuit & Breaking Capacity Ultimate short‑circuit breaking capacity (Icu) typical: ~50 kA at 380–415 V AC Lower values at higher AC voltages Suitable for industrial feeders and branch circuits Mechanical / Installation Fixed installation with front terminals Robust construction for industrial and commercial systems Mounting in distribution boards or control panels Standards & Compliance IEC/EN 60947‑2 CE compliant
Key Specifications General Product Type: Molded Case Circuit Breaker (MCCB) Series: ABB SACE Isomax S5 Poles: 3 Part Number: 1SDA038705R1 Rated Uninterrupted Current (Iu): 630 A Connection: Front terminals / fixed mounting Electrical Ratings Rated Operational Voltage (AC): up to 690 V AC Rated Insulation Voltage (Ui): 690–1000 V Rated Impulse Withstand Voltage (Uimp): 6–8 kV Interrupting/Breaking Capacity: High short‑circuit breaking capability for industrial distribution Protection & Trip Options Thermomagnetic or electronic trip units (optional, not fixed for this part number) Provides overload, short‑circuit, and optional ground‑fault protection Mechanical & Durability Fixed MCCB design for panel or distribution board mounting Robust mechanical construction for industrial and commercial power systems Standards & Compliance IEC/EN 60947‑2 compliant for low‑voltage switchgear Applications Industrial feeders and mains protection Distribution board incomers and branch circuits
Key Specifications General Product: Thermal overload relay Model: TA450DU310 Poles: 3 Overload Setting Range: 220–310 A Protection & Function Trip Class: Class 10 Reset: Manual or automatic Functions: Trip indication, test, stop Phase Unbalance/Single-Phase Protection: Built-in Auxiliary Contacts: 1 NO + 1 NC Electrical Ratings Rated Operational Current: up to 310 A (AC‑3) Rated Operational Voltage: up to 1000 V AC Rated Insulation Voltage (Ui): 690 V Rated Impulse Withstand Voltage (Uimp): 6 kV Auxiliary Circuit Ratings: up to 500 V AC / 440 V DC Mechanical / Installation Mounting: Close-coupled with ABB contactors (e.g., AF210, AF260, AF300) Front-accessible adjustment and reset Manual test button and trip indication Ambient-compensated overload protection Environmental Operating Temperature: –25 °C to +55 °C Pollution Degree: 3 Degree of Protection: IP20 Standards & Compliance IEC/EN 60947‑4‑1 UL, CSA, CE, RoHS
Key Specifications General Product Type: Three‑phase Soft Starter Model: PSTX60‑600‑70 Rated Operational Current: 60 A Input Voltage: 208–600 V AC Control Supply Voltage: 100–250 V AC 50/60 Hz Phase: 3‑phase Bypass: Built‑in Mounting: Inline (open style) Operating Temperature: ‑25 °C to +60 °C Motor & Performance Ratings Normal Duty Motor Power: ~20 HP @ 208 V AC, ~40 HP @ 460 V AC, ~50 HP @ 575 V AC Starting Capacity: ~400% of rated current for ~10 seconds Control & Ramp Functions: Voltage/torque ramp start and stop, current limit, kickstart Signals & Outputs: Run signal, torque signal, event/fault relays Protection Functions: Electronic overload protection, phase loss protection, motor heating monitoring, diagnostics Mechanical & Physical Degree of Protection: IP00 (open unit) Dimensions: ~314 mm (H) × 150 mm (W) × ~198 mm (D) Weight: ~6.1 kg Terminal Type: Screw/cable clamp Standards & Features Soft start and soft stop with torque or voltage control Diagnostic functions and sequence start capabilities Optional communication interfaces on some variants
Key Specifications Electrical Ratings Rated Current: 20 A Adjustment/Setting Range: 16–20 A Rated Operational Voltage: up to 690 V AC / 440 V DC Rated Operational Power (AC‑3, 400 V, 3‑phase): ~7.5 kW Full Load Current (Motor): ~27 A Rated Service Short‑Circuit Breaking Capacity (Ics): ~55 kA at 400 V AC Trip Class: 10 Poles: 3 poles Protection & Mechanisms Overload Protection: Adjustable thermal Short‑Circuit Protection: Magnetic Phase Loss Sensitivity: Included Trip‑Free Mechanism: Yes Disconnect Function: Yes Handle Indication: Clear ON/OFF Mechanical / Installation Operation Type: Manual (rotary handle) Terminal Type: Screw/thread connection Mounting: DIN‑rail or panel Enclosure Rating: IP20 Operating Temperature: –25 °C to +50 °C Dimensions: ~87.5 mm (H) × 54 mm (W) × 75.5 mm (D) Operating Cycles: ~100,000 Standards & Compliance IEC/EN 60947‑1, 60947‑2, 60947‑4‑1 UL508, CSA 22.2 No. 14 RoHS compliant
Key Specifications General Product Type: Molded Case Circuit Breaker (MCCB) Series: ABB SACE Tmax XT Poles: 3 Frame/Model: XT3N250 TMD250/2500 FF Rated Current: 250 A Trip Unit: Thermal‑magnetic (TMD), adjustable 175–250 A Voltage & Frequency Rated Operational Voltage (AC): 690 V AC Rated Operational Voltage (DC): Up to 500 V DC Rated Frequency: 50/60 Hz Electrical Ratings Rated Insulation Voltage (Ui): 800 V Rated Impulse Withstand Voltage (Uimp): 8 kV Rated Instantaneous Short‑Circuit Setting (Ii): 2500 A Rated Uninterrupted Current (Iu): 250 A Breaking Capacity Ultimate Breaking Capacity (Icu): ~50 kA at 220–240 V AC ~36 kA at 380–415 V AC DC Breaking Capacity (poles in series): ~36 kA @ 250 V DC ~50 kA @ 500 V DC Mechanical & Durability Power Loss: ~17.8 W per pole Electrical Durability: ~8 000 operations Mechanical Durability: ~25 000 operations Protection Class: IP20 Construction & Installation Fixed mounting with front (FF) terminals Suitable for industrial power distribution panels Standards & Safety Complies with IEC 60947‑2 CE and RoHS compliant
Key Specifications General Product: Safety relay, SSR42 series Manufacturer: ABB Part Number: 2TLA010053R0400 Supply Voltage: 24 V DC Mounting: DIN‑rail Terminal Type: Screw terminals Protection Rating: IP20 RoHS Compliant: Yes Inputs / Control Control Supply: 24 V DC Reset Mode: Manual or automatic selectable Outputs Contact Configuration: 2 NO safety outputs + 2 delayed NO outputs OFF‑Delay Time: ~1.5 seconds Rated Switching Current: 3 A (AC‑15 / DC‑13) Rated Contact Voltage: up to 250 V AC Mechanical Width: ~22.5 mm Height: ~120 mm Depth: ~120 mm Weight: ~0.207 kg Environmental Operating Temperature: ‑10 °C to +55 °C Safety & Standards For machine safety monitoring applications Meets relevant safety relay standards (e.g., ISO 13849; supports SIL depending on configuration)
Typical Parameters (General S204‑M Series) Electrical Ratings Rated Current (In): Various (e.g., 2 A, 6 A, 10 A, 16 A, 20 A, 32 A, etc.) depending on model Number of Poles: 4 Tripping Characteristic: Type C (moderate inrush tolerance) Rated Operational Voltage: 400 V AC Rated Insulation Voltage (Ui): 440 V AC Rated Impulse Withstand Voltage (Uimp): 4 kV Breaking Capacity (Icu): typically around 6–10 kA @ 230/400 V AC (model dependent) Service Breaking Capacity (Ics): ‑ (varies with exact product/spec sheet) Mechanical & Installation Mounting: DIN‑rail (TH35) Terminal Type: Screw terminals Actuator: Toggle handle Width: ~70 mm (4 modules) Height: ~85–88 mm Depth: ~69 mm Environmental & Protection Operating Temperature: -25 °C to +55 °C Storage Temperature: -40 °C to +70 °C Protection Degree: IP20 Pollution Degree: 3 Standards & Compliance IEC/EN 60898‑1 IEC/EN 60947‑2 Often UL or other regional approvals where applicable