Parameters: Rated Voltage: 380–600 V AC (Three-phase) Rated Current: 70 A Motor Power: Up to 55 kW at 600 V Up to 45 kW at 400 V Input Control Voltage: 24 V DC (external supply) Output Frequency: 0 to 500 Hz Bypass Contactors: Integrated bypass for energy savings once the motor reaches full speed Cooling Method: Forced air cooling (fan-assisted) Overload Capacity: 150% of rated current for 60 seconds 110% of rated current for 1 minute Dimensions (H x W x D): Approx. 400 x 250 x 250 mm (varies depending on configuration) Weight: Approx. 8 kg (varies depending on configuration) Degree of Protection: IP20 (For indoor use; optional kits available for enhanced protection) Ambient Temperature Range: -10°C to +50°C (with derating above 40°C) Control Method: Soft start with adjustable ramp-up and ramp-down times Certifications: CE marking, UL listed, IEC compliant Key Features:

Parameters: Model Number: ABB AF370-30 Rated Voltage: 380–690 V AC (Three-phase) Rated Current: 30 A Motor Power: Up to 18.5 kW at 400 V Up to 22 kW at 690 V Frequency: 50/60 Hz Protection Settings: Overload Protection: Adjustable settings to protect the motor from excessive current. Short-Circuit Protection: Provides protection from electrical short circuits. Phase Loss and Imbalance Protection: Detects phase loss or imbalance and trips the motor to prevent damage. Undervoltage Protection: Protects the motor from damage due to under-voltage conditions. Thermal Overload Protection: Monitors the motor’s temperature and prevents overheating. Control Voltage: 24 V DC (external supply) Operating Temperature Range: -20°C to +60°C Dimensions (H x W x D): Approx. 200 x 150 x 100 mm Mounting Type: DIN rail mount or panel mount Degree of Protection: IP20 (for indoor use) Weight: Approx. 1.5 kg Communication: Modbus RTU (optional for communication with PLCs and SCADA systems)

Parameters: Model Number: ABB UL-722D-R1A-B105-031 Rated Voltage: 380–690 V AC (Three-phase) Rated Current: 105 A Motor Power: Up to 75 kW at 690 V Up to 55 kW at 400 V Frequency: 50/60 Hz Protection Features: Overload Protection: Adjustable to protect against excessive current draw. Phase Loss Protection: Monitors phase imbalance and loss, providing protection against motor damage due to phase issues. Undervoltage and Overvoltage Protection: Protects the motor from damage caused by excessive voltage dips or spikes. Thermal Protection: Monitors the temperature and prevents overheating by disconnecting the motor in case of excessive thermal load. Short Circuit Protection: Protects the motor from the damage caused by electrical short circuits. Control Voltage: 24 V DC (external supply) Mounting Type: DIN rail mount or panel mount Cooling Method: Natural cooling or forced cooling with fan (depending on the specific model and configuration) Degree of Protection: IP20 (For indoor use; optional kits available for enhanced protection) Weight: Approx. 1.6 kg Dimensions (H x W x D): Approx. 170 x 120 x 120 mm (varies depending on configuration) Communication: Modbus RTU (optional for integration with PLCs and SCADA systems)

Parameters: Model Number: ABB 1SFB536271A1007 Rated Voltage: 380–690 V AC (Three-phase) Rated Current: 10–100 A (adjustable) Motor Power: Up to 75 kW at 690 V Up to 45 kW at 400 V Frequency: 50/60 Hz Protection Features: Overload Protection: Adjustable to prevent damage from excessive current. Short Circuit Protection: Protects the motor from damage caused by short-circuit faults. Phase Loss and Imbalance Protection: Detects loss of phases or phase imbalance and disconnects the motor to prevent motor damage. Undervoltage and Overvoltage Protection: Protects against damaging voltage dips or spikes that could cause harm to the motor. Thermal Overload Protection: Monitors motor temperature and prevents overheating. Control Voltage: 24 V DC (external supply) Mounting Type: DIN rail mount or panel mount Cooling Method: Natural or fan-assisted cooling depending on the application Degree of Protection: IP20 (for indoor use; optional additional protection available) Weight: Approx. 1.5 kg (varies depending on configuration) Dimensions (H x W x D): Approx. 200 x 150 x 100 mm (varies by model) Communication: Modbus RTU (optional for PLC/SCADA integration)

Parameters: Model Number: ABB 1SFB536268D1007 Rated Voltage: 380–690 V AC (Three-phase) Rated Current: 10–100 A (adjustable) Motor Power: Up to 75 kW at 690 V Up to 45 kW at 400 V Frequency: 50/60 Hz Protection Features: Overload Protection: Adjustable to protect against excessive motor current, preventing motor damage due to overloading. Short-Circuit Protection: Provides protection from electrical short circuits that could damage the motor. Phase Loss and Imbalance Protection: Detects phase loss or imbalance, and trips the motor to avoid damage caused by an unbalanced power supply. Undervoltage and Overvoltage Protection: Safeguards the motor against harmful voltage fluctuations that could lead to damage. Thermal Overload Protection: Monitors the motor’s temperature to prevent overheating and motor failure. Control Voltage: 24 V DC (external supply) Mounting Type: DIN rail mount or panel mount Cooling Method: Natural or forced cooling (depending on the configuration and load) Degree of Protection: IP20 (for indoor use; optional enhanced protection kits available) Weight: Approx. 1.6 kg (depending on configuration) Dimensions (H x W x D): Approx. 200 x 150 x 100 mm (varies by configuration) Communication: Modbus RTU (optional for integration with PLCs and SCADA systems)

Parameters: Model Number: ABB PSTX210-600-70 Rated Voltage: 380–600 V AC (Three-phase) Rated Current: 70 A Motor Power: Up to 55 kW at 600 V Up to 45 kW at 400 V Frequency: 50/60 Hz Control Method: Voltage Ramp: Adjustable ramp-up and ramp-down for smooth motor start and stop. Soft Start/Stop: Smooth acceleration and deceleration of the motor. Input Control Voltage: 24 V DC (external supply) Overload Capacity: 150% of rated current for 60 seconds 110% of rated current for 1 minute Cooling Method: Fan-assisted cooling (active cooling) Degree of Protection: IP20 (for indoor use; optional kits available for enhanced protection) Mounting Type: Panel mount, suitable for integration into motor control panels Dimensions (H x W x D): Approx. 300 x 200 x 150 mm (varies depending on configuration) Weight: Approx. 5.8 kg (varies depending on configuration) Thermal Protection: Adjustable thermal overload protection for the motor Ambient Temperature Range: -10°C to +50°C (with derating above 40°C) Communication: Optional Modbus RTU communication for integration with PLC/SCADA systems

Parameters: Model Number: ABB SACE PR122/P-LSI Rated Voltage: 400 V AC (Three-phase) Rated Current: 800 A, adjustable from 320 A to 800 A Frequency: 50/60 Hz Breaking Capacity (Icu): 50 kA at 400 V Protection Type: Long-Time Protection (LSI): Adjustable time delay to protect against prolonged overcurrents. Short-Time Protection (STI): Adjustable short-circuit protection with a time delay to avoid nuisance trips while ensuring protection against short circuits. Instantaneous Protection (I): Instantaneous tripping for severe short-circuit conditions, ensuring fast isolation of faults. Settings Range: Long-Time Protection (L): Adjustable from 0.7 to 1.0 times the rated current. Short-Time Protection (S): Adjustable between 3 to 10 times the rated current, with an adjustable delay. Instantaneous Protection (I): Instantaneous tripping for faults above the short-circuit threshold. Overload Protection: Provides reliable protection against motor overloads, preventing long-duration overcurrent conditions from damaging the equipment. Trip Unit: Digital microprocessor-based trip unit for accurate protection and control. Degree of Protection: IP20 (for indoor use) Mounting Type: DIN rail mount or panel mount Communication Options: Modbus RTU for remote monitoring and integration with PLC or SCADA systems Weight: Approx. 11 kg (depending on configuration) Dimensions (H x W x D): Approx. 450 x 250 x 200 mm (varies by configuration)

Parameters: Model Number: ABB SACE PR121/P-LSIG Rated Voltage: 400 V AC (Three-phase) Rated Current: 320 A to 800 A (adjustable) Frequency: 50/60 Hz Breaking Capacity (Icu): 50 kA at 400 V Protection Type: Long-Time Protection (L): Adjustable settings from 0.7 to 1.0 times the rated current to protect against prolonged overcurrents. Short-Time Protection (S): Adjustable from 3 to 10 times rated current with a time delay to prevent nuisance tripping while providing protection against short circuits. Instantaneous Protection (I): Instantaneous tripping for high fault conditions (short circuits), ensuring fast isolation of the fault. Ground Fault Protection (G): Adjustable ground fault protection to detect and isolate earth leakage currents to avoid damage to the system and prevent electric shocks. Overload Protection: Thermal overload protection for the motor or other connected load, ensuring that the equipment is not damaged by prolonged overcurrent conditions. Communication: Modbus RTU (optional) for integration with PLC/SCADA systems. Mounting Type: DIN rail mount or panel mount. Degree of Protection: IP20 (suitable for indoor use, additional protection can be added for harsh environments). Weight: Approx. 12.5 kg (depending on the specific configuration). Dimensions (H x W x D): Approx. 450 x 250 x 200 mm (subject to configuration).

Parameters: Model Number: ABB SACE PR121/P-LSI Rated Voltage: 400 V AC (Three-phase) Rated Current: 320 A to 800 A (adjustable) Frequency: 50/60 Hz Breaking Capacity (Icu): 50 kA at 400 V Protection Type: Long-Time Protection (L): Adjustable from 0.7 to 1.0 times rated current. Provides protection against prolonged overcurrents. Short-Time Protection (S): Adjustable from 3 to 10 times rated current, with a time delay for protecting against short-circuit conditions. Instantaneous Protection (I): Instantaneous tripping for severe short-circuit faults to prevent system damage. Thermal Overload Protection: Adjustable to monitor motor temperature and prevent damage from prolonged overloads. Short-Circuit Protection: Provides reliable protection from short-circuit faults, preventing catastrophic damage to electrical equipment. Control Voltage: 24 V DC (external supply) Mounting Type: DIN rail mount or panel mount Degree of Protection: IP20 (suitable for indoor use; optional protection kits for harsh environments) Weight: Approx. 12 kg (varies depending on configuration) Dimensions (H x W x D): Approx. 450 x 250 x 200 mm (varies depending on configuration) Modbus RTU Communication (Optional): For remote monitoring and integration with PLC or SCADA systems. Auxiliary Contacts (Optional): Available for integration into larger control systems for advanced monitoring and signaling.

Parameters: Model Number: ABB SACE PR121/P-LI Rated Voltage: 400 V AC (Three-phase) Rated Current: 320 A to 800 A (adjustable) Frequency: 50/60 Hz Breaking Capacity (Icu): 50 kA at 400 V Protection Type: Long-Time Protection (L): Adjustable from 0.7 to 1.0 times rated current. Protects the system from prolonged overcurrent conditions, preventing motor or equipment damage. Short-Time Protection (S): Adjustable from 3 to 10 times rated current, with an adjustable time delay, to prevent nuisance trips while providing protection against short circuits. Instantaneous Protection (I): Provides fast disconnection for severe short-circuit conditions to protect against high fault currents. Thermal Overload Protection: Continuously monitors the motor or equipment temperature to prevent overheating from prolonged overload conditions. Short-Circuit Protection: Safeguards against the damaging effects of short circuits, ensuring fast and reliable fault isolation. Control Voltage: 24 V DC (external supply) Mounting Type: DIN rail mount or panel mount Degree of Protection: IP20 (suitable for indoor use; optional kits for enhanced protection in harsh environments) Weight: Approx. 12 kg (depends on configuration) Dimensions (H x W x D): Approx. 450 x 250 x 200 mm (subject to configuration) Modbus RTU Communication (Optional): For integration with PLC or SCADA systems, allowing for remote monitoring, diagnostics, and control. Auxiliary Contacts (Optional): Available for use in larger control systems to provide feedback or fault signals to operators.

Parameters: Model Number: ABB 1SFL587002R1411 Rated Voltage: 400 V AC (Three-phase) Rated Current: 12 A to 32 A (adjustable) Frequency: 50/60 Hz Protection Type: Long-Time Protection (L): Adjustable settings from 0.7 to 1.0 times the rated current to protect against prolonged overcurrent conditions. Short-Time Protection (S): Adjustable settings for short-circuit protection, typically between 5 to 12 times the rated current with time delay. Instantaneous Protection (I): Immediate tripping for high fault currents to prevent severe system damage from short circuits. Thermal Overload Protection: Adjustable based on motor characteristics, typically covering a range of settings for protection against overheating. Breaking Capacity (Icu): 50 kA at 400 V Control Voltage: 24 V DC (external supply) Mounting Type: DIN rail mount or panel mount Degree of Protection: IP20 (for indoor use; optional protection kits for harsher environments) Auxiliary Contacts (Optional): Available for integration with control systems for signaling or fault monitoring. Weight: Approx. 1.8 kg Dimensions (H x W x D): Approx. 150 x 130 x 130 mm (varies depending on configuration)

Parameters: Model Number: ABB E3S 2000 PR121/P-LSIG Rated Voltage: 400 V AC (Three-phase) Rated Current: 320 A to 630 A (adjustable) Frequency: 50/60 Hz Protection Type: Long-Time Protection (L): Adjustable from 0.7 to 1.0 times rated current. Protects against prolonged overcurrents. Short-Time Protection (S): Adjustable from 3 to 10 times rated current, with time delay to prevent nuisance trips while offering protection against short circuits. Instantaneous Protection (I): Provides fast disconnection for severe short-circuit conditions to protect sensitive electrical equipment. Ground Fault Protection (G): Detects and isolates ground faults (leakage currents), helping to prevent electrical hazards and ensuring safety. Thermal Overload Protection: Monitors temperature and prevents motor or system overheating, preventing thermal damage. Breaking Capacity (Icu): 50 kA at 400 V Control Voltage: 24 V DC (external supply) Mounting Type: DIN rail mount or panel mount Degree of Protection: IP20 (for indoor use; optional protection kits for harsher environments) Weight: Approx. 7 kg (depending on configuration) Dimensions (H x W x D): Approx. 300 x 180 x 130 mm (varies depending on configuration) Modbus RTU Communication (Optional): For integration with PLC or SCADA systems, enabling remote monitoring, diagnostics, and fault detection. Auxiliary Contacts (Optional): Available for integrating with external control systems for monitoring or signaling.