Parameters: Rated Voltage: 380-690 V AC (Three-phase) Rated Current: 600 A Motor Power: Up to 1050 kW at 690 V Up to 750 kW at 400 V Input Control Voltage: 24 V DC (external supply) Output Frequency: 0 to 500 Hz Cooling: Forced air cooling (with fan) Protection Class: IP00 (standard) Ambient Temperature Range: -10°C to +50°C (with derating above 40°C) Overload Capacity: 150% of rated current for 60 seconds 110% of rated current for 1 minute Dimensions (H x W x D): Approx. 1,020 x 740 x 500 mm Weight: Approx. 115 kg (depends on configuration) Degree of Protection: IP20 (for indoor use, optional higher protection classes available with kits) Mounting: Wall-mountable Control Method: Soft start with adjustable ramp-up and ramp-down, with full motor protection features. Key Features: Smooth Motor Start/Stop: The PSTX1050-600-70 ensures a smooth motor start, reducing mechanical shock and inrush current, which extends motor and system life. Advanced Protection Features: Overload protection Phase loss and phase imbalance protection Motor and system diagnostics Overvoltage and undervoltage protection Ground fault protection (depending on configuration) Short-circuit protection
Parameters: Rated Voltage: 380–690 V AC (Three-phase) Rated Current: 600 A Motor Power: Up to 45 kW at 400 V Up to 600 kW at 690 V Input Control Voltage: 24 V DC (external supply) Output Frequency: 0–500 Hz Cooling: Forced air cooling (with fan) Protection Class: IP00 (Standard) Ambient Temperature Range: -10°C to +50°C (with derating above 40°C) Overload Capacity: 150% of rated current for 60 seconds 110% of rated current for 1 minute Dimensions (H x W x D): Approx. 820 x 510 x 430 mm Weight: Approx. 65 kg (varies with configuration) Degree of Protection: IP20 (for indoor use, higher protection available with optional kits) Mounting: Wall-mountable Control Method: Soft start with adjustable ramp-up and ramp-down, with motor protection features.
Parameters: Rated Voltage: 690 V AC (maximum voltage rating) Rated Current: 63 A Rated Frequency: 50/60 Hz Number of Poles: 3P (Three-pole) Breaking Capacity: 10 kA (short-circuit breaking capacity) Switch Type: Rotary handle, manually operated IP Protection Class: IP65 (dust-tight and protected against water jets) Control Voltage: 230 V AC (for control circuit) Mounting Type: Panel mount Dimensions (H x W x D): Approx. 160 x 140 x 120 mm (varies slightly with configuration) Weight: Approx. 1.5 kg (depends on configuration) Connection Type: Screw terminal connections for ease of installation Operating Temperature Range: -25°C to +55°C (typical range for industrial environments) Certifications: UL, IEC, CE compliant Key Features: High Breaking Capacity: The switch can handle high fault currents (up to 10 kA), ensuring safe disconnection during short-circuit conditions. Rotary Handle: The handle allows for manual operation, providing clear visibility of the switch position (on/off) for operator safety. IP65 Protection: This high level of protection ensures the switch can be used in harsh environments where dust and water exposure is a concern. Safety Features: Provides a visible isolation to confirm the circuit is disconnected. This helps prevent accidental re-energizing of the equipment during maintenance or repair work. Durability: The device is designed for long-term use in industrial environments, with high-quality materials that ensure reliable operation over time. Versatile Applications: Suitable for use in various electrical panels, switchgear, industrial control systems, and HVAC systems. Compact Design: The compact size makes it easy to integrate into panels where space is limited. Applications: Industrial Electrical Distribution: Used in electrical panels and switchgear for isolating electrical circuits during maintenance. Commercial Buildings: Suitable for use in electrical systems requiring safe and reliable disconnection of power supplies. HVAC Systems: Ensures safe isolation of power in HVAC systems, preventing electrical hazards during service or repair. Power Control Systems: Used for controlling and isolating power to motors, generators, and other electrical devices in industrial settings. Renewable Energy Systems: Can be used in solar panel or wind turbine systems to safely isolate circuits for maintenance.
Parameters: Rated Voltage: 690 V AC (Maximum voltage rating) Rated Current: 63 A Number of Poles: 3P (Three-pole) Breaking Capacity: 10 kA (Short-circuit breaking capacity) Switch Type: Rotary handle, manually operated Control Voltage: 230 V AC (for control circuits) IP Protection Class: IP65 (Dust-tight and protected against water jets) Mounting Type: Panel mount Dimensions (H x W x D): Approx. 160 x 140 x 120 mm (varies slightly depending on configuration) Weight: Approx. 1.5 kg (depends on specific configuration) Connection Type: Screw terminals for electrical connections Operating Temperature Range: -25°C to +55°C (operating temperature range) Certifications: UL, IEC, CE Compliant
Parameters: Rated Voltage: 690 V AC (Maximum operating voltage) Rated Current: 63 A Number of Poles: 3P (Three-pole) Rated Frequency: 50/60 Hz Breaking Capacity: 10 kA (Short-circuit breaking capacity) Switch Type: Rotary handle, manually operated Control Voltage: 230 V AC (for control circuits) Protection Class: IP65 (Dust-tight and protected against water jets) Mounting Type: Panel mount Dimensions (H x W x D): Approx. 160 x 140 x 120 mm (varies slightly depending on configuration) Weight: Approx. 1.5 kg (depends on configuration) Connection Type: Screw terminals Operating Temperature Range: -25°C to +55°C (Standard operational temperature range) Certifications: UL, IEC, CE Compliant
Parameters: Rated Voltage: 690 V AC (Maximum rated voltage) Rated Current: 63 A Number of Poles: 3P (Three-pole switch) Rated Frequency: 50/60 Hz Breaking Capacity: 10 kA (Short-circuit breaking capacity) Switch Type: Rotary handle, manually operated Control Voltage: 230 V AC (for control circuits) IP Protection Class: IP65 (Dust-tight and protected against water jets) Mounting Type: Panel mount Dimensions (H x W x D): Approx. 160 x 140 x 120 mm (Dimensions may vary depending on configuration) Weight: Approx. 1.5 kg (Varies depending on configuration) Connection Type: Screw terminals for electrical connections Operating Temperature Range: -25°C to +55°C (Standard operational temperature range) Certifications: UL, IEC, CE Compliant
Parameters: Model Number: UL-722D-R1A-B105-31 Rated Voltage: 600 V AC Rated Current (In): 105 A Rated Frequency: 50/60 Hz Frame Size: 722D (Molded Case Circuit Breaker Frame) Breaking Capacity: 18 kA (at 480 V AC) Protection Type: Thermal-magnetic (overload and short-circuit protection) Trip Curve: B Type B-type breakers trip between 3-5 times the rated current, ideal for sensitive loads and devices that might experience inrush currents but do not require frequent disconnections. Trip Settings (Overload): Adjustable between 100% and 120% of rated current Short-Circuit Protection: Magnetic (instantaneous) Poles: 3P (Three-pole configuration) Mounting Type: Panel mount Operating Temperature Range: -25°C to +70°C Degree of Protection: IP20 (protected against solid objects >12mm in diameter, suitable for indoor use) Dimensions (H x W x D): Approx. 188 x 120 x 150 mm (varies slightly depending on model and configuration) Weight: Approx. 2.3 kg (depends on configuration) Certifications: UL Listed, IEC compliant, CE marking
Parameters: Rated Voltage: 380–690 V AC (Three-phase) Rated Current: 600 A Motor Power: Up to 600 kW at 690 V Up to 450 kW at 400 V Input Control Voltage: 24 V DC (external supply) Output Frequency: 0 to 500 Hz Cooling: Forced air cooling (with fan) Ambient Temperature Range: -10°C to +50°C (with derating above 40°C) Overload Capacity: 150% of rated current for 60 seconds 110% of rated current for 1 minute Dimensions (H x W x D): Approx. 1010 x 740 x 500 mm (varies depending on configuration) Weight: Approx. 100 kg (varies depending on configuration) Degree of Protection: IP20 (for indoor use, optional higher protection classes available with kits) Mounting: Wall-mountable Control Method: Soft start with adjustable ramp-up and ramp-down, with full motor protection features. Bypass Contactors: Integrated bypass contactor for energy efficiency once the motor is up to full speed.
Parameters: Model Number: 721D-R1A-B025 Rated Voltage: 600 V AC (Maximum rated voltage) Rated Current (In): 25 A Rated Frequency: 50/60 Hz Poles: 3P (Three-pole) Breaking Capacity: 25 kA at 480 V AC (short-circuit breaking capacity) 10 kA at 600 V AC Protection Type: Thermal-magnetic (overload and short-circuit protection) Thermal Protection Setting: Adjustable, between 100% and 120% of rated current Magnetic Protection: Instantaneous short-circuit protection (with time delay for overloads) Trip Characteristics: B Type – Trips at 3-5 times rated current (for general applications, providing a balance between protection and inrush current tolerance). Dimensions (H x W x D): Approx. 105 x 60 x 110 mm (depending on the specific configuration) Weight: Approx. 0.6 kg Degree of Protection: IP20 (Protected against solid objects >12 mm in diameter, suitable for indoor use) Mounting Type: Panel mount or DIN rail mount (for flexible installation options) Control Voltage: 230 V AC (for control circuits) Operating Temperature Range: -5°C to +40°C (operating ambient temperature) Certifications: UL Listed, CE marking, IEC Compliant
Parameters: Rated Voltage: 380–690 V AC (Three-phase) Rated Current: 70 A Motor Power: Up to 55 kW at 690 V Up to 45 kW at 400 V Input Control Voltage: 24 V DC (external supply) Output Frequency: 0 to 500 Hz Bypass Contactors: Integrated bypass contactors for energy savings once the motor reaches full speed Cooling Method: Forced air cooling (fan-assisted) Overload Capacity: 150% of rated current for 60 seconds 110% of rated current for 1 minute Dimensions (H x W x D): Approx. 400 x 250 x 250 mm (varies depending on configuration) Weight: Approx. 8 kg (depends on configuration) Degree of Protection: IP20 (For indoor use; optional kits for enhanced protection available) Ambient Temperature Range: -10°C to +50°C (with derating above 40°C) Control Method: Soft start, ramp-up, and ramp-down control with full motor protection features. Certifications: CE marking, UL listed, IEC compliant
Parameters: Rated Voltage: 380–600 V AC (Three-phase) Rated Current: 105 A Motor Power: Up to 75 kW at 600 V Up to 55 kW at 400 V Input Control Voltage: 24 V DC (external supply) Output Frequency: 0 to 500 Hz Bypass Contactors: Integrated bypass for energy-saving once the motor reaches full speed Cooling Method: Forced air cooling (fan-assisted) Overload Capacity: 150% of rated current for 60 seconds 110% of rated current for 1 minute Dimensions (H x W x D): Approx. 500 x 300 x 250 mm (varies depending on configuration) Weight: Approx. 15 kg (depends on configuration) Degree of Protection: IP20 (For indoor use; optional kits available for enhanced protection) Ambient Temperature Range: -10°C to +50°C (with derating above 40°C) Control Method: Soft start with adjustable ramp-up and ramp-down times Certifications: CE marking, UL listed, IEC compliant
Parameters: Rated Voltage: 380–600 V AC (Three-phase) Rated Current: 70 A Motor Power: Up to 55 kW at 600 V Up to 45 kW at 400 V Input Control Voltage: 24 V DC (external supply) Output Frequency: 0 to 500 Hz Bypass Contactors: Integrated bypass contactor for energy efficiency once the motor reaches full speed Cooling Method: Forced air cooling (fan-assisted) Overload Capacity: 150% of rated current for 60 seconds 110% of rated current for 1 minute Dimensions (H x W x D): Approx. 400 x 250 x 250 mm (varies depending on configuration) Weight: Approx. 8 kg (varies depending on configuration) Degree of Protection: IP20 (For indoor use; optional kits available for enhanced protection) Ambient Temperature Range: -10°C to +50°C (with derating above 40°C) Control Method: Soft start with adjustable ramp-up and ramp-down times Certifications: CE marking, UL listed, IEC compliant