Industrial Controller
All product are in stock,guaranteed delivery within 3-7 days.
Infinite Innovation, the Future of Industrial Control Systems
Infinite Innovation, the Future of Industrial Control Systems
PRODUCT POSITION:HOMEPRODUCT—S202-K20 2CDS252001R0487
S202-K20 2CDS252001R0487
Technical Specifications / Parameters Parameter Specification Manufacturer Order Code 2CDS252001R0487 Catalogue Type S202-K20 Brand / Series ABB S200 Series (System PRO M) Device Type Miniature Circuit Breaker (MCB) Number of Poles 2-Pole (2P) Rated Current (In) 20 A Rated Operational Voltage (Ue) 230/400 V AC Rated Insulation Voltage (Ui) 440 V AC Rated Impulse Withstand Voltage (Uimp) 6 kV Tripping Characteristic K Curve (Specifically designed for high inrush loads. Instantaneous tripping range: ~8In to 12In). Rated Breaking Capacity (Icn) 10 kA (at 400V AC, per IEC/EN 60947-2) Utilization Category A (Instantaneous tripping with no intentional delay for short-circuit) Standards Compliance IEC/EN 60947-2 (Industrial circuit-breaker standard) Terminal Type Cage Clamp Terminal Connectable Conductors Solid/Fine-stranded Copper: 0.75 - 35 mm² (Torque: 3.0 - 3.5 Nm) Electrical Endurance ≥ 20,000 cycles (at In) Mechanical Endurance ≥ 20,000 cycles Ambient Temperature -25°C to +60°C (for calibration, derating above +40°C) Mounting DIN Rail (35 mm, EN 60715) Module Width 36 mm (2 Poles) Primary Functions Overload Protection, Short-Circuit Protection (High Inrush Immune) Protection Features Trip-free mechanism, "ON"/"OFF" visual indication. Accessory Compatibility Compatible with the full range of S200 Series System PRO M accessories: auxiliary contacts (OF, SD), alarm contacts (OF), shunt trips, undervoltage releases, etc. Common Approvals CE, UL 1077 (Supplemental Protector), CCC, etc.
DESCRIBE
The ABB S202-K20 (Order Code: 2CDS252001R0487) is a 20A, 2-pole, K-curve Miniature Circuit Breaker (MCB) from the ABB S200 Series (System PRO M). This specialized MCB is designed for industrial and commercial applications where protection of circuits with very high inrush currents, particularly from transformers, solenoid valves, and certain types of lighting (e.g., discharge lamps), is required. The "K" curve features a delayed and higher magnetic trip setting compared to standard curves, providing immunity to short-duration, high-magnitude startup surges while maintaining robust protection against sustained overloads and short circuits.
SERVICE HOTLINE Grace +86 13600179521
Mail jilineasyyi@outlook.com ADDRESS Unit 12, 20th Floor, Good View Commercial Centre, 2-16 Garden Street, Mong Kok, Hong Kong
Q Q: info@hongkongeasy.com
吉林易择科技技术发展有限公司 吉ICP备2024020526号-1
js