EZ1000
Key Features: ✔ Multi-Sensor Support – Works with eddy current probes, velocity sensors, and accelerometers ✔ Dual-Channel Input – Monitors two independent measurement points simultaneously ✔ Programmable Alarms – Configurable Warning/Danger thresholds with relay outputs ✔ Flexible Outputs – 4–20 mA, ±10 V, RS-485 (Modbus), and optional PROFIBUS ✔ Wide Frequency Range – Covers 0.1 Hz – 10 kHz (displacement) and 1 Hz – 1 kHz (velocity/acceleration) ✔ Industrial Durability – IP65-rated enclosure, operates in -20°C to +70°C Typical Applications: Turbines, compressors, pumps, and motors Condition monitoring & predictive maintenance Integration with PLC/DCS systems The EZ1000 enhances operational safety and reduces downtime by providing real-time vibration analysis and alarm-based protection.
DESCRIBE
General Specifications
Model: EZ1000 (configurable for different sensor types)

Application: Machinery protection (turbines, compressors, pumps, fans, etc.)

Compliance: ISO 10816, ISO 7919 (vibration standards)

Input Signals
Sensor Compatibility:

Eddy Current Probes (e.g., 8mm, 11mm) – for displacement measurement

Velocity Sensors (e.g., 4–20 mA seismic transducers)

Accelerometers (optional IEPE support)

Channels: Typically 2 independent channels (can vary by model)

Measurement Ranges:

Displacement: 0–2000 µm (peak-to-peak, adjustable)

Velocity: 0–100 mm/s (RMS)

Acceleration: 0–20 g (peak)

Signal Processing
Frequency Range:

Displacement (Proximity): 0.1 Hz – 10 kHz

Velocity/Acceleration: 1 Hz – 1 kHz (typical)

Sampling Rate: High-resolution ADC (e.g., 10 kHz per channel)

Filtering: Configurable high-pass/low-pass filters

Outputs & Communication
Analog Outputs:

4–20 mA (isolated, proportional to vibration level)

±10 V DC (for direct signal analysis)

Digital Communication:

RS-485 (Modbus RTU protocol)

Optional PROFIBUS-DP or Ethernet (model-dependent)

Relay Outputs:

2–4 relays per channel (configurable for Alert/Danger thresholds)

Relay rating: 250 VAC/5 A (resistive load)

Alarm & Protection
Programmable Setpoints: Adjustable Warning and Danger limits per channel

Dynamic Alarm Delay: Prevents false triggers (0.1–10 sec adjustable)

Power Supply
Voltage: 24 VDC (±10%) or 100–240 VAC (50/60 Hz)

Power Consumption: ≤5 W

Environmental Conditions
Operating Temperature: -20°C to +70°C

Storage Temperature: -40°C to +85°C

Enclosure Rating: IP65 (dustproof & water-resistant)

Certifications
CE, RoHS, ISO 9001

ATEX/IECEx (for hazardous area models, if applicable)

Typical Applications
Continuous monitoring of rotating machinery (e.g., turbines, gearboxes).

Condition-based maintenance to prevent failures.

Integration with DCS/PLC systems via analog or Modbus.

For exact specifications, refer to the official EPRO EZ1000 datasheet (configurations may vary by model).