Technical Parameters Specification Details Product Type Signaling I/O accessory module Intended Use Status feedback for electronic trip units in low‑voltage breakers Compatible Breakers ABB Tmax XT series (XT2, XT4, XT5) and breakers with Ekip trip units Function Provides breaker status signals (open, closed, tripped) to the trip unit Input/Output Role Status signaling; supplies breaker condition data to protection/control logic Connection Interface Internal accessory terminals on breaker frame Mounting Installed inside breaker accessory space (internal accessory) Status Signals Provided Breaker open/closed status, tripped status Use Case Local signaling, integration with external control panels, interlocks, automation systems Typical Application Remote indication, control logic input, system supervision Design Accessory module configured by default with terminal connections
Technical Parameters Specification Details Product Type Communication module for circuit breakers Series / Platform ABB Ekip COM Compatibility Ekip electronic trip units (Emax, Emax 2, Tmax XT) Supported Protocols Modbus RS‑485, Modbus TCP, Ethernet/IP, PROFIBUS DP, PROFINET (variant dependent) Remote Control Breaker open/close commands Remote Status Breaker position, trip/fault indication, alarms Network Interfaces RS‑485 terminal block, Ethernet RJ45 Installation Plug-in or mountable accessory on breaker or terminal box Power Supply Supplied from breaker auxiliary circuits Indicators LEDs for communication and module status Configuration Via Ekip Connect software or network configuration tools Standards Compliance IEC/EN low-voltage breaker accessory and industrial communication standards Typical Applications Remote monitoring, breaker automation, integration with PLC/SCADA, distributed protection system
Technical Parameters Specification Typical Details Product Type Monitoring & Diagnostics Interface Module Model Name / Code MT585 Product Family ABB SMiS (Switchgear Monitoring & Insight System) Application Module for data acquisition and condition monitoring in medium‑voltage switchgear Typical Inputs Sensor/monitoring data from temperature, current, voltage sensors (via digital/analogue inputs) Typical Outputs Data communication to higher‑level protection or asset management systems Integration Integration with SCADA/remote asset manager, IoT platforms Mounting DIN‑rail or switchgear panel installation Communication Likely supports standard fieldbus / ethernet / MODBUS or similar (application‑dependent) Operating Environment Designed for industrial switchgear conditions Standards Designed to comply with switchgear monitoring and electrical distribution standards Typical Uses Condition monitoring, predictive maintenance, remote diagnostics, protection system data
Technical Parameters Specification Details Product Type Voltage measuring / monitoring module Model / Part Number VM210 (also known as 1SDA059602R1) Applicable Trip Units PR223DS, PR223EF (electronic trip units) Intended Circuit Breakers ABB low‑voltage breakers with compatible trip units (T4, T5, T6 series) Function Network voltage measurement and signal conversion for protection trip units Power Supply (Auxiliary) 24 V DC ±20% Power Supply Ripple ±5% Operating Temperature Range ‑25 °C to +70 °C Relative Humidity 5% to 98% (non‑condensing) Maximum Trip Unit Connections Up to 5 trip units per module Maximum Cable Distance to Trip Unit 15 meters (shielded cable recommended above 1 m) Certifications / Standards Product environmental tests per IEC 60068, EMC per IEC 61000 Typical Electrical Signals Provided Voltage outputs proportional to line voltages for each phase (L1, L2, L3) Application Used as part of protection schemes to provide accurate voltage measurement data
Typical Technical Parameters Specification Details Product Type Operator/Display Panel for Motor Control & Protection Units Model Name / Accessory MD21 Intended For Use With ABB M10x Motor Control & Protection Units (e.g., M101, M102) Display Type LCD with text and value readouts LED Indicators Configurable status indicators (Power, Ready, Running, Stop, Fault, etc.) Function Buttons Start, Stop, Navigation (Up/Down/Enter/Exit) Communication / Connection RJ11/RS‑485 interface to M10x controller Parameterization Port Mini USB for engineering access and parameter setup Supported Display Pages Up to 13 running values and settings pages (with M102) Measurement Data Motor current, % current, line voltage*, power and power factor*, thermal capacity, frequency* (features depend on connected control unit) Diagnostic Data Fault logs, trip history, maintenance information Physical Mounting Mounts on the front of M10x unit or panel door Typical Uses Local monitoring, control, status indication, parameter configuration Compatible Control Modules M101, M102 (Motor control and protection units) Typical Environments Industrial motor control panels and automation boards
Typical Technical Parameters Specification Details Product Type PLC CPU Module Series ABB AC500 Model PM585‑ETH Control Processor High‑performance ARM‑based CPU (varies by firmware) Power Supply 24 V DC typical Communication Ethernet interface (LAN) Ethernet Ports Multiple RJ45 Ethernet ports Expandable I/O Yes — supports S500 / S500‑eCo modules Communication Protocols Modbus TCP/UDP, Profibus, Ethernet variants (with modules) Memory Program and data memory (depends on exact firmware) Mounting DIN‑rail / control panel Operating Temperature Industrial operating range Standards Designed for industrial control use
Technical Parameters Specification Details Product Type Fuse Switch Disconnector Model / Part Number XLP000 / XLP000‑6CC Brand ABB Series EasyLine XLP Number of Poles 3‑pole (3P) Rated Operational Current (Ie) Up to 100 A (AC‑22B at 500 V AC) / ~80 A (AC‑23B at 400 V AC) Rated Permanent Current (Iu) ~50 A Rated Operational Voltage (Ue) 400 V AC, 500 V AC, 690 V AC Rated Frequency 50/60 Hz Rated Conditional Short‑Circuit Current (Icn) 50 kA RMS (at 690 V) Rated Insulation Voltage (Ui) ~690 V Rated Impulse Withstand Voltage (Uimp) 6 kV Fuse Types Supported NH000, NH00 fuse links Connection Type Cable clamp connectors Mounting Baseplate or busbar mounting Actuator Position Front side handle Degree of Protection IP30 (front) Safety Version Can be used as main switch and safety switch Suitable For AC and DC disconnection in fused circuits Typical Applications Isolation & protection in distribution panels, switchboards, industrial control systems
Typical Technical Parameters Specification Details Product Type Electronic Trip Unit / Protection Relay Model / Part Family PR121/P Intended Use Protection unit for ABB SACE Emax low‑voltage air circuit breakers Applicable Poles 3‑pole (3P) and also compatible with 4‑pole breakers Protection Functions Overload (long‑time), short‑time, instantaneous short‑circuit, earth (ground) fault protection (depending on version) Technology Digital microprocessor‑based unit Self‑Supply No external power required for core protection functions; self‑supplied from sensed current Adjustable Settings Adjustable current thresholds and time delays for protective functions Neutral Protection Setting Configurable (OFF / 50% / 100% / 200% of phase current where applicable) Trip Cause Indication LED indicators and trip history User Interface DIP switches or configuration tools for setting protection parameters Optional Interfaces Connectivity with external modules (for remote signaling, communications, test interfaces) Rated Frequency 50/60 Hz Compliance Designed for IEC low‑voltage circuit breaker standards (trip functions compatible with IEC/EN 60947‑2)
Technical Parameters Specification Details Product Type Low‑Voltage Air Circuit Breaker (ACB) Series / Model SACE Emax 2 E4.2S‑A 3200 Rated Current (In / Iu) 3200 A continuous rating Poles 3‑pole (three‑phase) or 4‑pole (with neutral option) Rated Operational Voltage (Ue) 690 V AC (standard low‑voltage distribution) Rated Insulation Voltage (Ui) 1000 V AC Rated Impulse Withstand Voltage (Uimp) 12 kV Short‑Circuit Breaking Capacity (Icu) • 85 kA at 220–440 V AC • 66 kA at 500–690 V AC Rated Service Short‑Circuit Breaking Capacity (Ics) Same as Icu (100 % of rated) Short‑Time Withstand Current (Icw) ~66 kA for 1 s / 3 s Mechanical Durability ~20 000 operations Electrical Durability ≥ 7000 operations at rated load Release / Trip Unit Ekip electronic trip units (Ekip Dip, Ekip Touch), configurable Short‑Circuit Performance Level S level (industrial performance) Standards Compliance IEC/EN 60947‑2 series (International standards) Terminal Connection Type Rear bolt‑type terminals (horizontal/rear orientation) Tightening Torque (Main Terminals) ~70 N·m Suitable for IT Networks Yes (up to 690 V) Applications Main / feeder breaker, motor/transformer protection, general distribution circuits
Technical Parameters Specification Details Product Type Low‑Voltage Air Circuit Breaker (ACB) Series / Model F4S 3200 A Rated Current (In) 3200 A Number of Poles 4‑pole (three‑phase + N) Rated Operational Voltage Up to 1000 V AC/DC (depending on version and trip unit) Protection Capabilities Overload, short‑circuit, and fault protection with adjustable trip units Trip Unit Options Electronic trip units (PR series such as PR122 / PR123) configurable for protection curves Rated Insulation Voltage (Ui) Typically 1000 V Rated Impulse Withstand Voltage (Uimp) High industrial impulse withstand (e.g., ~6–12 kV, product dependent) Control and Auxiliary Integration Support for auxiliary contacts, shunt releases, under‑voltage releases, and motor operators Mounting Type Fixed installation in switchgear or power distribution panel Terminal Type Bolted or clamp main terminals Standards Compliance IEC/EN 60947‑2 and related global electrical safety standards Typical Short‑Circuit Breaking Capacity High breaking capacity suitable for industrial systems (specific kA rating depends on region and trip unit) Mechanical Durability Designed for high cycle life in heavy‑duty use Applications Main and feeder protection in industrial, commercial, and infrastructure electrical distribution
Technical Parameters Specification Details Product Type Low‑Voltage Air Circuit Breaker (ACB) Series / Model F5 S4000A (Megamax F5 series) Rated Uninterrupted Current (In) 4000 A continuous Number of Poles 3‑pole (three‑phase) Rated Operational Voltage Up to 690 V AC (standard LV distribution) Utilization Category Protection and isolation in power distribution Trip Unit / Protection Adjustable electronic or thermal‑magnetic trip units (e.g., PR1, LSIG options) Short‑Circuit Breaking Capacity High breaking capacity suitable for industrial systems (application dependent) Mounting Type Fixed installation in switchgear or panel Connection Type Bolt‑on / clamp terminals (application dependent) Standards Compliance IEC/EN 60947‑2 series (typical for LV circuit breakers) Weight & Dimensions Large industrial frame (approx. several hundred kg and ~500–600 mm per side—model dependent) Typical Operating Frequency 50 Hz / 60 Hz compatible Typical Applications Main / feeder breaker in electrical distribution, industrial power panels, protection of transformers and large loads
Technical Parameters Specification Details Product Air Circuit Breaker Series / Model ABB E3S2000 Rated Operational Current (Iu) 2000 A Poles 3‑pole (three‑phase) Rated Operational Voltage up to 690 V AC Short‑Circuit Breaking Capacity (Icu) up to ~75 kA @ 400 V AC Overcurrent Protection Unit Adjustable long‑time, short‑time, instantaneous, ground fault options depending on trip unit Trip Unit Type PR122 / P‑LSI or similar protection units available Auxiliary Contacts Multiple auxiliary contacts for breaker status and remote signaling Mounting Type Fixed installation — panel or switchgear mounting Connection Style Rear or front terminals depending on configuration Standards Compliance IEC/EN 60947‑2 and related low‑voltage protection standards Protection Functions Overload, short‑circuit, ground fault (depending on trip unit options)