PRODUCT
PICTURE
BRAND
DESCRIBE
STOCK
DOWNLOAD
Technical Parameters General Product Type: Joystick operator (pilot device) Model: MJS1-60B Actuator Type: Maintained joystick, 2 positions Illumination: Non-illuminated Actuator Color: Black Bezel / Housing: Chrome metal Contact Blocks: Not included (modular system) Installation Type: Panel mounting with snap-on contact block support Operator Function: Maintained (latching) 2-position control Mechanical & Durability Mechanical Life: Approx. 500,000 operations Panel Cut-out Diameter: Standard 22 mm Dimensions: Approx. 43 mm (H) × 48 mm (W) × 97 mm (D) Weight: Approx. 0.06 kg Environmental & Protection Operating Temperature Range: −25 °C to +70 °C Storage Temperature Range: −40 °C to +85 °C Front Protection Rating: IP66 / IP67 / IP69K (with appropriate sealing accessories) Standards Compliance: Conforms to industrial control and signaling product standards Electrical Electrical Contacts: Not included — contact modules must be ordered separately and installed as needed Connection Type: Modular snap-on contact blocks (screw or spring clamp blocks available separately) Typical Applications Machine control panels (direction or function selection) Mode selection for automated systems Manual directional control for conveyors, hoists, and motors Operator interface for industrial equipment Override or local control stations in automation environments
Technical Parameters General Product Type: Moulded Case Circuit Breaker (MCCB) Series: ABB Tmax T5 Model: T5S630 TMA500/2500-5000 FF 3P Poles: 3 (three-pole fixed device) Mounting Type: Fixed front-terminal (FF) connection Rated Values Rated Current (Iₙ): 500 A (continuous) Rated Uninterrupted Current (Iu): ~630 A Operational Voltage: up to 690 V AC (AC systems) / up to 750 V DC Rated Insulation Voltage (Ui): 1000 V Rated Impulse Withstand Voltage (Uimp): 8 kV Trip & Protection Trip Unit Type: Thermal-Magnetic (TMA) Adjustable Instantaneous Short-Circuit Setting: 2500 A … 5000 A Overload Protection: Thermal element Short-Circuit Protection: Magnetic instantaneous element Breaking Performance Rated Service Short-Circuit Breaking Capacity (Ics): e.g., up to 50–85 kA at 230–400 V AC depending on exact variant Rated Ultimate Short-Circuit Breaking Capacity (Icu): similar high kA ratings up to several ten kA range (application dependent) Mechanical & Durability Electrical Durability: ~5000 operations Mechanical Durability: ~20000 operations Ambient Conditions: Standard industrial electrical environment (e.g., –25 °C to +70 °C) Physical & Installation Terminal Type: Front connect (FF) Device Width / Dimensions: Typical for 630 frame series Connection: Fixed panel mounting Standards & Compliance Designed per IEC 60947-2 low-voltage circuit breaker standards ✔ Typical Applications Power distribution protection in industrial & commercial systems Feeder & branch circuit protection Motor and load protection Transformer feeder protection Panel board and switchboard installation
Technical Parameters General Product Type: Selector switch Model: C2SS1-30R-11 Actuator Type: Rotary selector, short handle Operating Function: Maintained (latching) Number of Positions: 2 Illumination: Non-illuminated Handle Color: Red Bezel Material: Metal Panel Cut-out: 22 mm Auxiliary Contacts: 1 Normally Open (NO) + 1 Normally Closed (NC) Electrical Ratings Rated Operational Voltage: Up to 300 V Rated Frequency: 50 / 60 Hz Rated Operational Current: AC-15: up to 1 A at 220–240 V AC DC-13: up to 0.3 A at 24–125 V DC Contact Material: Silver alloy Connection Type: Screw terminals Mechanical & Environmental Mechanical Life: Up to 500,000 operations Degree of Protection (Terminals): IP20 Ambient Operating Temperature: −25 °C to +70 °C Storage Temperature: −30 °C to +85 °C Pollution Degree: 3 Applications Control panels and operator stations Machine mode selection Motor forward / reverse selection Manual control and signaling in industrial automation systems
Technical Parameters General Product Type: AC power contactor Model: AX80-30-11 Number of Poles: 3 Auxiliary Contacts: 1 Normally Open (NO) + 1 Normally Closed (NC), built-in Operating Principle: Electromagnetic, AC coil Electrical Ratings Rated Operational Voltage (Main Circuit): up to 690 V AC Rated Operational Current (AC-3): 80 A Rated Operational Current (AC-1): up to 125 A Rated Operational Power (AC-3, 400 V): up to 37 kW Frequency: 50 / 60 Hz Coil Control Voltage: Depends on coil version (e.g. 110 V AC, 220–240 V AC) Coil Type: AC operated Mechanical & Installation Mounting: DIN rail or panel mounting Construction: Block type Accessory Compatibility: Side-mounted auxiliary contact blocks, mechanical interlocks, surge suppressors Applications Motor starting and stopping Power circuit switching Industrial automation and control panels Pump, fan, compressor, and conveyor control systems
Key English Specifications Parameter Value / Description Contactor Type 3‑pole, non‑reversing magnet contactor Main Contacts 3 × Normally Open (NO) Auxiliary Contact 1 built‑in auxiliary contact Control Coil Voltage 24–60 VAC (50/60 Hz) or 20–60 VDC — wide control range Rated Operational Voltage (Ue) Up to 690 V AC (IEC standard) Rated Current (AC‑1) ~30 A Rated Motor Load (AC‑3) ~18 A (≈7.5 kW / 400 V) Maximum Load/Power Up to ~7.5 kW (AC‑3) Termination Screw terminals Mounting DIN rail or panel mount Design/Features AF technology with wide control voltage range, reduced power consumption, built‑in surge protection, compact block design Application Motor control, automation systems, switching circuits in industrial panels Standards IEC 60947 compliant Weight ~0.31 kg Typical Operating Frequency 50/60 Hz Operating Temperature Range Typical industrial duty range
Key Parameters Parameter Value / Description Product Type Rotary handle operating mechanism Model / Code RHE A1‑A2 Standard Returned ABB Catalog No. 1SDA066158R1 ABB Order Code KA2RHE Intended For MCCB FORMULA Series Frame Compatibility A1 and A2 frame sizes Operating Style Rotary handle — standard returned Mounting Feature Adjustable depth for various door thicknesses Additional Features Padlock provision, door interlock Standards / Approvals IEC compliant, UL recognized (region dependent) Weight ~0.45 kg Typical Use External operating handle for circuit breaker panel doors Environmental / Compliance REACH / RoHS compliant Function Standard returned — handle returns to neutral position after operation A1‑A2 Compatible with A1 and A2 frame MCCBs
Typical Parameters Parameter Symbol Typical Value / Description Module Type - Phase-Control Thyristor Module (Half-Controlled Bridge) Circuit Configuration - T21 (Two thyristors + two diodes, forming a half-controlled bridge leg). Repetitive Peak Off-State Voltage VDRM / VRRM 800 V to 1600 V (Common ratings: 1200V, 1400V, 1600V). Average On-State Current (Per Thyristor) IT(AV) 220 A (At a specified case temperature, e.g., Tc=80°C). This is likely the rated current indicated by "220" in the model. RMS On-State Current IT(RMS) ~ 347 A (Approx. π * IT(AV) for sine wave conduction). Non-Repetitive Peak Surge Current ITSM 3000 A to 4000 A (Typical for 10 ms half-sine wave). Gate Trigger Current IGT 200 mA (Typical). Gate Trigger Voltage VGT 1.5 V (Typical). Thermal Resistance, Junction-to-Case Rth(j-c) 0.08 °C/W to 0.12 °C/W (Per thyristor/diode, typical). Isolation Voltage Visol 2500 V RMS (Min., baseplate to terminals). Mounting - Module with isolated baseplate for screw mounting onto a heatsink with thermal grease. Terminals - Screw terminals for main power (AC input, DC output) and gate control signals. Operating Junction Temperature Tj -40 °C to +125 °C (Standard range).
Typical Parameters Parameter Description / Typical Value Module Type Fail-Safe Digital Input Module System Compatibility ABB Freelance DCS, AC 800F Controller, S800 I/O or F-I/O Series. Number of Channels 16 channels (common for this form factor). Input Type Dry Contact (volt-free contact) or Wet Contact (sourcing DC voltage). Nominal Input Voltage 24 VDC (most common). Also available in versions for 48 VDC and 125 VDC. Input Signal Level "0" (OFF): Typically < 5V DC. "1" (ON): Typically 15-30V DC (for 24V nominal). Input Current Typically ~5-10 mA per channel (at nominal voltage). Isolation Channel-to-Channel: Yes (typically 500V AC). Channel-to-Bus: Yes (optical isolation). Diagnostics Yes. Includes wire-break/short-circuit detection, module failure, and communication loss. Update Time Very fast, typically 1-10 ms per module (configurable). Backplane Bus S800 I/O Bus or Profibus-DP/PA, depending on the specific system configuration and the interface module used (e.g., CI871). Power Supply Requires 24 VDC for internal electronics, typically sourced from the system power supply or the field side. LED Indicators Per-channel status LEDs (Green/Red) and module status LEDs (RUN, ERR, etc.). Certifications Complies with CE, UL, cUL, and relevant industrial standards (IEC 61131).
Typical Parameters Parameter Description / Typical Value Model / Type MT-305B - NTC Thermistor Probe Resistance Value 5 kΩ (Kilo-ohms) at a specified reference temperature (e.g., R₂₅ = 5kΩ @ 25°C). This is the most critical parameter. Beta Value (β) A specific constant (e.g., 3470K, 3950K) that defines the resistance-temperature curve/characteristic. Essential for accurate temperature calculation. Tolerance Resistance tolerance at reference temperature (e.g., ±1%, ±5%). Defines measurement accuracy. Temperature Range Operating Range: Typically -50°C to +150°C (common for epoxy-coated NTCs). Exact range depends on construction. Probe Material & Construction Stainless steel sheath, epoxy-coated bead, or glass-encapsulated. Determines response time and environmental durability. Lead Wires Insulated copper wires (e.g., PVC, Teflon), specified length. Time Constant The time required for the sensor to respond to 63.2% of a step change in temperature (e.g., a few seconds in air or liquid). Dissipation Constant The power required to raise the thermistor's temperature by 1°C above its surroundings (in mW/°C). Important for self-heating error consideration. Application Temperature sensing in HVAC controls, battery packs, electronic assemblies, industrial processes, and consumer appliances.
Typical Parameters Parameter Description / Inferred Value Model Series MJS Series (Standard Cast Iron Motor) Motor Type Three-Phase, Squirrel Cage Induction Motor Rated Output Power 0.75 kW (1 HP) *[Common interpretation: "60" often indicates ~0.75kW/1HP in this series.]* Number of Poles 4 *[Suffix "B" in older ABB codes typically denotes 4-pole.]* Synchronous Speed 1500 rpm (at 50Hz) Rated Speed ~1400 rpm (at 50Hz, 4-pole) Supply Voltage & Frequency 400 V, 3-phase, 50 Hz (Most common. May also be designed for 415V, 380V, or 460V/60Hz). Rated Current ~1.8 A (approximate at 400V, 50Hz, 0.75kW) Efficiency Class IE2 (High Efficiency) – Standard for its manufacturing period. Insulation Class Class F (with temperature rise according to Class B). Protection Class (IP) IP55 (Dust protected and protected against water jets). Cooling Method (IC) IC 411 (Totally Enclosed Fan Cooled - TEFC). Mounting (IM) IM B3 (Standard foot-mounted). Duty Cycle S1 (Continuous duty). Ambient Temperature Max. 40°C (standard). Altitude Max. 1000 m above sea level (standard). Connection Star (Y) / Delta (Δ) – Terminal board usually allows connection changes for different voltages.
Parameter Description / Typical Range Model Series OHB / HXR Series (High Voltage Motors) Type Three-Phase, Squirrel Cage, High Voltage Induction Motor Rated Output Power ~ 200 kW to 1000+ kW (The "S2" often indicates a specific frame size range for higher power, e.g., ~400-800 kW). Rated Voltage 3300 V, 6600 V, 11000 V (or other standard MV levels like 4160V, 13800V depending on region). Frequency 50 Hz or 60 Hz. Number of Poles 4, 6, 8, 10, or 12 poles (对应同步转速: 1500, 1000, 750, 600, 500 rpm @ 50Hz). Rated Speed Depends on poles (e.g., ~1485 rpm for 4-pole, ~990 rpm for 6-pole @ 50Hz). Insulation Class Class F (with temperature rise according to Class B for long life). Protection Class IP54 or IP55 (common for high voltage motors). Cooling Method IC 81W (Air-cooled, with integrated air-to-water heat exchanger) or IC 611 (Closed air circuit with air/air cooler) for dirty environments. Mounting IM B3 (Foot-mounted) is standard. IM B35 (Foot and flange) is also common. Service Factor / Duty Cycle S1 (Continuous duty). Starting Method Designed for direct-on-line (DOL) starting or with soft starters/VSDs. Ambient Temperature Max. 40°C (standard). Higher ambient options available. Altitude Up to 1000 m above sea level (standard). Efficiency Complies with IE3 (Premium Efficiency) or higher (IE4) per IEC 60034-30-1 for high voltage motors. Standards Designed to IEC 60034 standards. May also meet IEEE 841 (for severe duty) or API 541 (for oil & gas) upon request.
Key Parameters Parameter Description / Typical Value Model OHB274J12 Type Three-Phase Squirrel Cage Induction Motor Output Power 15 kW (20 HP) *[Note: "274" in ABB coding often corresponds to 15kW/20HP frame]* Rated Voltage 400 V (or other standard voltages like 690V, depending on design region) Frequency 50 Hz (or 60 Hz, or dual-frequency) Rated Speed ~1470 rpm (for 4-pole design at 50Hz) Number of Poles 4 (Synchronous speed: 1500 rpm @ 50Hz) Rated Current ~28-30 A (at 400V, 50Hz) [Exact value depends on efficiency & power factor] Efficiency Class IE3 (Premium Efficiency) or IE2 (High Efficiency) per IEC 60034-30 standards. Insulation Class F (with temperature rise according to Class B, ensuring long life). Protection Class IP55 (Dust protected and protected against water jets from any direction). Cooling Method IC 411 (Totally Enclosed Fan Cooled - TEFC). Mounting IM B3 (Foot-mounted) or IM B35 (Foot-mounted with flange) - common variants. Ambient Temperature Max. 40°C (as standard). Altitude Max. 1000 m above sea level (as standard). Duty Cycle S1 (Continuous duty). Standards Designed in accordance with IEC standards (e.g., IEC 60034). Design Standard N-design (normal starting torque, normal starting current, low slip).