PRODUCT
PICTURE
BRAND
DESCRIBE
STOCK
DOWNLOAD
Technical Data: Series: Magnecraft / ABB 10 Series Contact Configuration: The standard MM10UR module itself is a single-pole, double-throw (SPDT) relay, also known as 1 Form C. Contacts: 1 Normally Open (NO) and 1 Normally Closed (NC). Coil Voltage: Universal (AC/DC). Rated Voltage Range: 200 - 250V AC, 50/60 Hz AND 200 - 250V DC. Contact Rating (Switching Capacity): Resistive Loads (AC-1): Typically 10 A @ 250V AC / 10 A @ 30V DC. Inductive Loads (AC-15, DC-13): Lower ratings apply (e.g., ~2-3A for motor starters). Always consult the data sheet for specific load category ratings. Electrical Life: Mechanical Life: Typically 10 million operations minimum. Electrical Life: Depends on load; e.g., 100,000+ operations at rated resistive load. Mounting: Designed for use with a standard 8-pin or 11-pin plug-in socket (e.g., ABB PK10 series sockets), which is then mounted on a 35mm DIN-rail. Terminals: Plug-in design for easy replacement. Status Indicator: Red flag/mechanism provides clear, visual indication of the relay's energized/de-energized state. Transient Protection: Not internally fitted as standard. A built-in metal-oxide varistor (MOV) surge suppressor is available as an option (typically denoted by an additional suffix like /M or /V). Standards Compliance: UL 508, CSA, CE, IEC/EN 61810-1.
Technical Parameters Parameter Specification Rated Current (In) 2000 A Number of Poles 3P Rated Operational Voltage (Ue) Up to 690 V AC Rated Insulation Voltage (Ui) 1000 V AC Rated Impulse Withstand Voltage (Uimp) 12 kV Short-Circuit Breaking Capacity (Icu) 66 kA (400–690 V AC) Rated Service Short-Circuit Breaking Capacity (Ics) 66 kA Short-Time Withstand Current (Icw) 66 kA for 1 s / 50 kA for 3 s Rated Uninterrupted Current (Iu) 2000 A Trip Unit Type Electronic trip unit (Ekip Dip) Terminal Connection Rear flat horizontal terminals Mechanical Durability ~25,000 operations Electrical Durability 8,000–10,000 operations Standards Compliance IEC 60947‑2
Technical Parameters Parameter Specification Rated Current (In) 200 A (trip unit setting max) Frame Size 250 A Number of Poles 3P Trip Unit Type Thermomagnetic Adjustable (TMA) Current Setting Range ~140 – 200 A (adjustable) Rated Operational Voltage 690 V AC / 500 V DC Rated Insulation Voltage (Ui) 1000 V Rated Impulse Withstand Voltage (Uimp) 8 kV Rated Uninterrupted Current (Iu) 250 A Rated Ultimate Short‑Circuit Breaking Capacity (Icu) ~50 kA at 380–400 V AC Rated Service Short‑Circuit Breaking Capacity (Ics) ~50 kA at 380–400 V AC Electrical Durability ~8,000 operations Mechanical Durability ~25,000 operations Terminal Connection Front terminals (bolted) Standards Compliance IEC 60947‑2
Technical Parameters Parameter Specification Rated Uninterrupted Current (Iu) 80 A Rated Current Setting Range (Thermal) 56 A – 80 A Number of Poles 3 Rated Operational Voltage Up to 690 V AC Rated Insulation Voltage (Ui) 800 V Rated Impulse Withstand Voltage (Uimp) 8 kV Rated Ultimate Short‑Circuit Breaking Capacity (Icu) 16 kA at 380–415 V AC Rated Service Short‑Circuit Breaking Capacity (Ics) 16 kA at 380–415 V AC Connection Type Front terminals (for copper cables up to ~70 mm²) Mechanical Durability ~25,000 operations Electrical Durability ~8,000 operations Trip Unit Type Thermomagnetic (overload + instantaneous magnetic) Terminal Cable Size Up to ~70 mm² Cu Standards Compliance IEC 60947‑2
Technical Parameters Parameter Specification Rated Operational Current (Ie) 40 A in various AC utilization categories (AC‑21A/AC‑22A/AC‑23A) at 380–415 V, 500 V, and 690 V AC Number of Poles 4 (three phases + neutral) Rated Operational Voltage Up to 800 V AC (main circuit) Rated Insulation Voltage (Ui) 800 V Rated Impulse Withstand Voltage (Uimp) 8 kV Rated Short‑time Withstand Current (Icw) 2.5 kA for 1 s Rated Operational Power (AC‑23A) ~18.5 kW at 400–415 V, 22 kW at 500 V, 37 kW at 690 V AC Thermal Current (Ith) 40 A Control Voltage (Motor) 230 V AC (motor drive to operate switch) Manual Operation Direct mounted handle included Cable Cross‑Section Range ~2.5–25 mm² or 2×2.5–16 mm² (typical) Degree of Protection (Front) IP20 Pollution Degree 3 (industrial environment) Mounting Type Base/front mounting Switch Transition Type Open transition Standards Compliance IEC/EN 60947 series typical for switch disconnectors
Technical Parameters Parameter Specification Rated Uninterrupted Current (Iu) 800 A Number of Poles 4 P Rated Operational Voltage (Ue) Up to 690 V AC Rated Insulation Voltage (Ui) 1000 V AC Rated Impulse Withstand Voltage (Uimp) 12 kV Rated Ultimate Short‑Circuit Breaking Capacity (Icu) 66 kA (400–690 V AC) Rated Service Short‑Circuit Breaking Capacity (Ics) 66 kA Short‑time Withstand Current (Icw) 66 kA for 1 s / 50 kA for 3 s Rated Operational Frequency 50 / 60 Hz Trip Unit Type Electronic (Ekip series) Terminal Connection Rear flat horizontal terminals Mechanical Durability ~25,000 operations Electrical Durability ~15,000 operations Standards Compliance IEC 60947‑2
Technical Parameters Parameter Specification Model / Part Number 1SFA892014R1002 (PSS300/515‑500L) Product Type Soft Starter (motor starting controller) Rated Operational Voltage (Main Circuit) 208 – 500 V AC Rated Control Supply Voltage 220 – 240 V AC Rated Control Circuit Voltage 24 V DC (for control signals) Rated Frequency 50/60 Hz Rated Operational Current (Ie) 300 A (in‑line) Rated Operational Current (Delta) 515 A (inside delta connection) Rated Operational Power (Motor) ~90 kW at 230 V AC, ~160 kW at 400 V AC, ~200 kW at 500 V AC Ramp Times Adjustable: Start 1 – 30 s, Stop 0 – 30 s Initial Start Voltage ~30 % – 70 % of line voltage Current Limiting Function 1.5 – 4 × Ie when CT connected Number of Starts per Hour ~30 (at 3.5×Ie, 7 s on, 50 % duty) Bypass Signal Relay Yes Fault Signal Relay (NO contact) Yes Ambient Operating Temperature –25 °C to +60 °C Ambient Storage Temperature –40 °C to +70 °C Protection Rating (Main Terminals) IP00 (internal), requires appropriate enclosure for IP protection Terminal Type Main circuit bars (bus bar style) Duty Cycle Up to ~30 starts/hour under specified conditions Product Weight ~23.9 kg Dimensions (Approx.) Height ~340 mm, Width ~356 mm, Depth ~265 mm Standards Compliance IEC 60529, IEC 60947 series
Technical Parameters Parameter Typical Specification Type Molded Case Circuit Breaker (MCCB) Series/Family ABB Tmax T with PR221DS electronic trip Poles 3P (three phases) Rated Current (In) e.g., 630 A (varies by specific model) Trip Unit Type PR221DS electronic solid‑state release Rated Operational Voltage (Ue) Up to 690 V AC Rated Insulation Voltage (Ui) 1000 V AC Rated Impulse Withstand Voltage (Uimp) 8 kV Short‑Circuit Breaking Capacity (Icu) Up to 50 kA (varies with frame/size) Service Short‑Circuit Breaking Capacity (Ics) Defined per voltage; depends on model Terminal Connection Front terminals (fixed) Mounting Configuration Fixed frame Trip Functions Electronic overload and short‑circuit protection Standards Compliance IEC 60947‑2 (Low‑Voltage Circuit Breakers) Typical Use Electrical distribution panels, motor feeders, industrial systems
Technical Parameters Parameter Typical Specification Rated Current (In) 400 A Number of Poles 3 P Rated Operational Voltage (Ue) Up to 600–690 V AC (50/60 Hz) Rated Insulation Voltage (Ui) ~1000 V AC Rated Impulse Withstand Voltage (Uimp) ~8 kV Short‑Circuit Breaking Capacity (Icu) 35 kA to 100 kA @ 480 V AC (depends on trip unit and design class) Electrical +1 Service Short‑Circuit Breaking Capacity (Ics) Typically equal or close to Icu depending on frame/trip unit Trip Unit Types Thermal‑magnetic (TMA/TMD) or Electronic (PR221DS, Ekip series) Frequency 50/60 Hz Terminal Connection Fixed front terminals Mechanical Durability ~20,000 operations (typical) Standards Compliance IEC 60947‑2 / UL 489 (depending on region)
Technical Parameters Parameter Specification Model / Part Number 1SDA010623R1 Product Type Molded Case Circuit Breaker (MCCB) Series / Family ABB S6 / S6H Rated Current (In) 800 A Number of Poles 3 (3‑pole) Rated Operational Voltage (Ue) Typically up to 400–690 V AC (three‑phase systems) Rated Insulation Voltage (Ui) ~800–1000 V AC Interruption Capacity Designed for high fault interrupting capability — varies by standard/region Trip Unit Options Thermal‑magnetic or solid‑state (depending on exact variant) Mounting Type Fixed frame MCCB Terminal Type Front or rear load/line terminals depending on configuration Standards Compliance IEC 60947‑2 or equivalent (international MCCB standard)
1. General Data Model: DT 30806-9 16/26 Type: Universal, Loop-Powered, 2-Wire Series: TTH/TTL 300 Mounting: 35 mm DIN Rail (EN 60715) Display: Integrated LCD with backlight (Model "16" indicates display version) Communication: HART Protocol (FOUNDATION Fieldbus compatible), versions 5/6/7 2. Input Specifications Sensor Types: RTD: Pt100, Pt500, Pt1000 (to IEC 60751), Ni100, LG-Ni, Cu10, etc. Thermocouple: Types J, K, T, N, E, R, S, B, L, U, C (to IEC 60584). Ohms/mV: Linear resistance or millivolt input. Sensor Connection: RTD: 2-, 3-, or 4-wire connection (automatic lead resistance compensation for 3/4 wire). Thermocouple: 2-wire connection (internal or external cold junction compensation). 3. Output & Power Analog Output: 4-20 mA DC, two-wire. Load Limit: Maximum loop resistance: Typically 750 Ω at 24 V DC (consult datasheet for full load curve). Power Supply: 12 to 35 V DC (standard loop supply). Operation is dependent on total loop resistance. 4. Performance Reference Accuracy (at 23°C ±5°C): RTD (Pt100): Typically ±0.05% of span or ±0.03°C (whichever is greater). Thermocouple: Typically ±0.1% of span or ±0.5°C (whichever is greater). Note: Accuracy varies by sensor type and range. Refer to official data for exact values. Temperature Coefficient: Typically < ±0.015% of span per 10°C. Update Time: Configurable, typically < 500 ms. Long-Term Stability: Typically < ±0.1% of span per year. 5. Ambient Conditions Ambient Operating Temperature: -40°C to +85°C (-40°F to +185°F). Storage Temperature: -50°C to +100°C. Relative Humidity: 5% to 95%, non-condensing. Electromagnetic Compatibility (EMC): Compliant with IEC/EN 61326. Ingress Protection (IP): IP20 (terminal area - requires installation in an enclosure for protection). Vibration / Shock: Compliant with IEC/EN 60068-2-6 / 60068-2-27. 6. Electrical & Mechanical Terminals: Spring-clamp terminals. Wiring: 0.2 - 2.5 mm² (AWG 24-12). Electrical Isolation: Input to output to ground: Typically 500 V AC. 7. Certifications & Approvals (Typical) The suffix "-9" often indicates a specific set of international approvals. This model is commonly certified for: ATEX / IECEx: For use in Hazardous Areas (e.g., Ex ia IIC T4 Ga / Ex ia IIC T4 Gb). cULus: Listed for Class I, Division 1, Groups A, B, C, D T4; or Class I, Zone 0, AEx/Ex ia IIC T4. FM: Similar approvals for North America. CE Marking: Compliant with EU directives. SIL: Capable of supporting Safety Integrity Level (SIL 2) applications in accordance with IEC 61508.
Specifications 1. General Data Manufacturer Part Number: 84200940 Order Code / Article Number: 3HNE04393-6 (Verify for your specific batch) Product Type: PM 5xx-Bus Interface Module for CANopen Compatible System: ABB AC 500 V3 PLC Series (e.g., CPUs PM5xx-...) 2. Communication Specifications Fieldbus Protocol: CANopen (compliant with CiA standards) Supported Profiles: CiA DS-301 (CANopen application layer & communication profile) CiA DSP-402 (Drive profile) Operating Modes: Configurable as Master or Slave. Baud Rate: Configurable, standard range from 10 kbit/s up to 1 Mbit/s. 3. Physical Interface Connector: 1 x 9-pin D-Sub male (plug) connector. Pinout (CiA 303-1 compliant): Pin 2: CAN_L Pin 7: CAN_H Pin 3: CAN_GND (for shield) Pin 9: CAN_V+ (optional external power, typically not used) Termination: Integrated 120 Ω terminating resistor, activatable/deactivatable via DIP switch or software. 4. Electrical Characteristics Power Supply: Powered via the PLC backplane (PM 5xx bus). Isolation: Galvanic isolation between the bus side and the PLC backplane for noise immunity and protection. Bus Standard: Compliant with ISO 11898. 5. Ambient Conditions Operating Temperature: 0°C to +60°C. Storage Temperature: -25°C to +85°C. Relative Humidity: 5% to 95%, non-condensing. Degree of Protection: IP20 (for installation inside a control cabinet). 6. Mechanical Specifications Module Width: Typically 25 mm (standard for AC 500 V3 I/O modules). Mounting: Snaps onto a top-hat DIN rail (35 mm x 7.5 mm or 15 mm) and connects via the PM 5xx system bus. 7. Configuration & Software Engineering Tool: Configured and parameterized using the ABB Automation Builder suite. Data Exchange: CANopen Process Data Objects (PDOs) and Service Data Objects (SDOs) are mapped directly to the PLC's I/O image and memory areas within the software. 8. Approvals & Certifications (Typical) CE: Compliant with EU directives. cULus: Listed for North America (Industrial Control Equipment). RCM: For the Australian market. Maritime: May hold specific shipboard approvals (e.g., DNV GL) for relevant variants.