Industrial Controller
All product are in stock,guaranteed delivery within 3-7 days.
Infinite Innovation, the Future of Industrial Control Systems
Infinite Innovation, the Future of Industrial Control Systems
PRODUCT HOME>>PRODUCT
PRODUCT

PRODUCT

PICTURE

BRAND

DESCRIBE

STOCK

DOWNLOAD

Parameters: Model Number: ABB SACE PR122/P-LI Rated Voltage: AC 690 V (for three-phase systems, common in industrial setups) Rated Current: 50 A to 2500 A (depending on model and configuration) Frequency: 50/60 Hz Protection Type: Long-Time Protection (L): Adjustable settings, typically ranging from 0.7 to 1.0 times rated current, providing overload protection to safeguard against sustained overcurrent conditions. Short-Time Protection (S): Adjustable from 3 to 10 times rated current with time delay, protecting against short-circuit faults while allowing for motor startup. Instantaneous Protection (I): Provides instantaneous disconnection in case of severe short-circuit conditions, ensuring the system is protected from high fault currents immediately. Ground Fault Protection (G): Ground fault protection detects any leakage current and isolates the faulty section, enhancing safety by preventing electrical shock and equipment damage. Thermal Overload Protection: Ensures protection against overheating due to prolonged overload conditions by monitoring the temperature of the system. Breaking Capacity (Icu): 50 kA at 400V, ensuring safe interruption of high fault currents without damaging the system. Mounting Type: DIN rail or panel mountable for integration into motor control centers (MCCs), distribution panels, and electrical control systems. Protection Class: IP20 (suitable for indoor environments; external protection kits available for more demanding environments). Weight: Approx. 10–15 kg, depending on the rated current and configuration. Dimensions (H x W x D): Approx. 300 x 200 x 150 mm (varies with configuration). Control Voltage: Typically 24 V DC or 48 V DC, but depends on model and configuration. Communication Protocols: Can be equipped with communication modules for integration with systems using Modbus RTU, Profibus, or Ethernet for remote monitoring, diagnostics, and control.

Parameters: Model Number: ABB E1N1250 R400/800/1250 3/4P Rated Voltage: AC 690 V (three-phase system) Rated Current: 400A, 800A, and 1250A (adjustable depending on configuration) Rated Frequency: 50/60 Hz Number of Poles: 3P (three-pole) or 4P (four-pole) Protection Type: Long-Time Protection (L): Adjustable from 0.7 to 1.0 times rated current, offering overload protection and preventing damage due to prolonged overcurrent conditions. Short-Time Protection (S): Adjustable from 3 to 10 times rated current, with time delay, providing protection against short-circuit faults while allowing for motor startup. Instantaneous Protection (I): Offers instantaneous disconnection in case of severe short-circuit conditions, ensuring protection from high fault currents. Ground Fault Protection (G): Ground fault protection (LSI) detects leakage currents and isolates the faulty section, providing safety from electrical hazards. Thermal Overload Protection: Monitors the temperature of the system and prevents overheating caused by sustained overload conditions. Breaking Capacity (Icu): 70 kA at 400V, ensuring safe interruption of high fault currents without damaging the system. Mounting Type: DIN rail mountable or panel mountable for easy integration into motor control centers (MCCs), distribution panels, and electrical control systems. Protection Class: IP20 (for indoor use; additional kits available for more demanding environments). Weight: Approx. 15–25 kg, depending on the rated current configuration. Dimensions (H x W x D): Approx. 350 x 250 x 180 mm (varies with rated current configuration). Control Voltage: 24 V DC (or 48 V DC depending on configuration) for remote control and communication features. Communication Protocols: Supports Modbus RTU, Profibus, and Ethernet for remote monitoring, diagnostics, and integration into PLC or SCADA systems. Auxiliary Contacts (Optional): Available for signaling faults and system status updates, useful for integration into control and automation systems.

Parameters: Model Number: ABB E1N1000 R400/800/1000 3/4P Rated Voltage: AC 690 V (three-phase system) Rated Current: 400A, 800A, 1000A (adjustable depending on configuration) Frequency: 50/60 Hz Number of Poles: 3P (three-pole) or 4P (four-pole) Protection Type: Long-Time Protection (L): Adjustable from 0.7 to 1.0 times rated current, offering overload protection for sustained overcurrent conditions. Short-Time Protection (S): Adjustable from 3 to 10 times rated current, with a time delay, providing protection against short-circuit faults while allowing for motor startup. Instantaneous Protection (I): Provides instantaneous disconnection in case of severe short-circuit conditions, ensuring the system is protected from high fault currents. Ground Fault Protection (G): Ground fault protection (LSI) detects leakage currents and isolates the faulty section, improving safety by preventing electrical hazards. Thermal Overload Protection: Monitors the temperature of the system and prevents overheating due to prolonged overload conditions. Breaking Capacity (Icu): 50 kA at 400V, ensuring safe interruption of high fault currents without damaging the system. Mounting Type: DIN rail mountable or panel mountable, making it easy to install in motor control centers (MCCs), distribution boards, and electrical control systems. Protection Class: IP20 (for indoor use; external protection kits available for more demanding environments). Weight: Approx. 10–20 kg, depending on the rated current and configuration. Dimensions (H x W x D): Approx. 300 x 200 x 180 mm (varies with rated current configuration). Control Voltage: Typically 24 V DC or 48 V DC for remote control and communication features. Communication Protocols: Can be equipped with Modbus RTU, Profibus, and Ethernet communication modules for remote monitoring, diagnostics, and integration into PLC or SCADA systems. Auxiliary Contacts (Optional): Available for signaling faults, system status updates, and integration into control systems.

Parameters: Model Number: ABB E1N800 R400/630/800 3/4P Rated Voltage: AC 690 V (for three-phase systems) Rated Current: 400A, 630A, 800A (adjustable depending on the configuration) Rated Frequency: 50/60 Hz Number of Poles: 3P (three-pole) or 4P (four-pole) Protection Type: Long-Time Protection (L): Adjustable from 0.7 to 1.0 times rated current, offering protection against overload by monitoring prolonged overcurrent conditions. Short-Time Protection (S): Adjustable from 3 to 10 times rated current, with a time delay, providing protection from short-circuit faults while allowing motor startup. Instantaneous Protection (I): Provides instantaneous disconnection in case of severe short-circuit conditions, ensuring immediate protection from high fault currents. Ground Fault Protection (G): Ground fault protection (LSI) detects leakage currents, providing early warning and isolating the faulty section to prevent electrical hazards. Thermal Overload Protection: Continuously monitors the system's temperature, offering protection against sustained overload conditions that could cause overheating. Breaking Capacity (Icu): 50 kA at 400V, ensuring that the breaker can safely interrupt high fault currents without damage to the system. Mounting Type: DIN rail mountable or panel mountable for easy integration into motor control centers (MCCs), distribution panels, and electrical control systems. Protection Class: IP20 (for indoor use; additional external kits are available for more demanding environments). Weight: Approx. 10–20 kg, depending on the rated current and configuration. Dimensions (H x W x D): Approx. 300 x 200 x 180 mm (varies depending on rated current configuration). Control Voltage: 24 V DC (or 48 V DC depending on configuration) for remote control and monitoring features. Communication Protocols: Supports Modbus RTU, Profibus, and Ethernet communication for remote diagnostics and integration with PLC or SCADA systems. Auxiliary Contacts (Optional): Available for fault signaling, system status updates, and integration with automation control systems.

Parameters: Model Number: ABB E3H2500 R2500 PR121/P-LI FHR 3P Rated Voltage: AC 690 V (for three-phase systems) Rated Current: 2500A (adjustable in different configurations) Frequency: 50/60 Hz Number of Poles: 3P (three-pole configuration) Protection Type: Long-Time Protection (L): Adjustable from 0.7 to 1.0 times rated current, providing overload protection to prevent damage from prolonged overcurrent. Short-Time Protection (S): Adjustable from 3 to 10 times rated current, with a time delay, protecting the system from short-circuit faults while allowing motor startup. Instantaneous Protection (I): Offers instantaneous disconnection during severe short-circuit conditions, ensuring protection from high fault currents. Ground Fault Protection (G): Ground fault protection (LSI) detects leakage currents, isolating the faulty section to enhance system safety. Thermal Overload Protection: Protects the system from overheating by continuously monitoring the temperature and responding to prolonged overloads. Breaking Capacity (Icu): 50 kA at 400V, providing safe interruption of high fault currents without damaging the system. Mounting Type: DIN rail mountable or panel mountable, making it easy to integrate into motor control centers (MCCs), distribution panels, and electrical control systems. Protection Class: IP20 (indoor use; additional protection kits available for more demanding environments). Weight: Approx. 30–40 kg, depending on rated current configuration. Dimensions (H x W x D): Approx. 500 x 400 x 250 mm (varies with rated current). Control Voltage: Typically 24 V DC or 48 V DC for remote control and monitoring. Communication Protocols: Supports Modbus RTU, Profibus, Ethernet, and other protocols for remote monitoring, diagnostics, and integration into PLC or SCADA systems. Auxiliary Contacts (Optional): Available for fault signaling, system status updates, and integration with control and automation systems.

Parameters: Model Number: ABB SACE Emax2 E1.2N 1250A 3P Rated Voltage: AC 690 V (for three-phase systems) Rated Current: 1250A (adjustable in different configurations) Frequency: 50/60 Hz Number of Poles: 3P (three-pole configuration for three-phase systems) Protection Type: Long-Time Protection (L): Adjustable from 0.7 to 1.0 times rated current, providing overload protection to prevent damage from prolonged overcurrent. Short-Time Protection (S): Adjustable from 3 to 10 times rated current, with a time delay, protecting against short-circuit faults while allowing for motor startup. Instantaneous Protection (I): Provides instantaneous disconnection in case of severe short-circuit conditions, ensuring protection from high fault currents. Ground Fault Protection (G): Ground fault protection (LSI) detects leakage currents, preventing electrical hazards by isolating the faulty section. Thermal Overload Protection: Continuously monitors the system's temperature, offering protection against overheating due to prolonged overload conditions. Breaking Capacity (Icu): 50 kA at 400V, ensuring safe interruption of high fault currents without damaging the system. Mounting Type: DIN rail mountable or panel mountable, making it easy to integrate into motor control centers (MCCs), distribution panels, and electrical control systems. Protection Class: IP20 (for indoor use; additional external protection kits are available for more demanding environments). Weight: Approx. 10–20 kg, depending on rated current configuration. Dimensions (H x W x D): Approx. 300 x 200 x 180 mm (varies depending on rated current configuration). Control Voltage: Typically 24 V DC or 48 V DC for remote control and monitoring features. Communication Protocols: Supports Modbus RTU, Profibus, and Ethernet communication for remote diagnostics and integration with PLC or SCADA systems. Auxiliary Contacts (Optional): Available for fault signaling, system status updates, and integration with automation control systems.

Parameters: Model Number: ABB VD4/Z-12.12.40 Rated Voltage: 12 kV (for medium voltage networks) Rated Current: 630 A (standard current rating for most applications) Rated Short-Circuit Breaking Capacity (Isc): 12.5 kA at 12 kV (designed to interrupt high fault currents) Rated Making Capacity (Icm): 50 kA at 12 kV (withstand the stresses of a fault current) Frequency: 50/60 Hz Number of Poles: 3P (three-pole design for three-phase systems) Arc Quenching Medium: Vacuum (vacuum interrupter for high reliability and low maintenance) Mounting Type: Fixed or withdrawable, suitable for integration in switchgear assemblies and panel mounting. Insulation Type: Air insulation for compact and efficient design. Protection Class: IP20 (standard for indoor applications; external kits are available for outdoor use). Mechanical Life: 30,000 operations (significantly longer life compared to traditional air circuit breakers). Weight: Approx. 120-200 kg, depending on configuration and accessories. Dimensions (H x W x D): Approx. 1000 x 600 x 500 mm (varies with installation configuration). Rated Voltage for Interruption: 12 kV Control Voltage: 24 V DC (for external control and monitoring systems). Auxiliary Contacts (Optional): Available for fault signaling, remote monitoring, and integration with automation systems.

Parameters: Model Number: ABB ACS510-01-017A-4 Rated Output Power: 17 kW (approximately 25 HP) Input Voltage Range: 380–480 V, 3-phase power supply Rated Input Current: 32.4 A (at 380 V) Frequency Range: 0 to 500 Hz Control Type: V/f (Volts per Hertz) control, open-loop control, sensorless vector control (for optimized motor performance) Motor Control: Suitable for controlling squirrel-cage motors in both constant torque and variable torque applications. Ambient Temperature Range: -10°C to +50°C (at full rated current) Protection Class: IP20 (for indoor use, additional protection kits available for harsher environments) Cooling: Forced air cooling (fan inside the drive) Efficiency: Typically 97%, providing energy savings in a variety of industrial applications. Dimensions (H x W x D): Approx. 420 x 220 x 175 mm (varies by configuration) Weight: Approx. 6.5 kg Control Voltage: 24 V DC (for control circuitry) Mounting: Wall or panel mountable (with standard mounting holes for ease of installation) Communication Protocols: Available for integration with Modbus RTU, Profibus DP, and DeviceNet for remote control and monitoring via automation systems. Keypad: Equipped with an integrated keypad for local configuration, parameter adjustment, and diagnostics. A digital display shows operational data and fault information. Built-in Protection Features: Overload Protection: With built-in motor protection features such as overload protection and over-temperature protection. Short-circuit Protection: Designed to protect the drive against short circuits and faults. Over-voltage/Under-voltage Protection: Includes protection against supply voltage anomalies. Overload Capacity: Can handle up to 150% of rated current for 60 seconds (typical overload capacity for VFDs).

Parameters: Model Number: ABB ACS510-01-012A-4 Rated Output Power: 12 kW (approximately 16 HP) Input Voltage Range: 380–480 V, 3-phase power supply Rated Input Current: 22 A (at 380 V) Frequency Range: 0 to 500 Hz Control Method: V/f (Volts per Hertz) Control: Basic method for variable-speed motor control. Sensorless Vector Control (SVC): Provides precise control of motor speed and torque, even at low speeds, without the need for external sensors. Motor Control: Ideal for variable torque applications like fans, pumps, compressors, and conveyors. Ambient Temperature Range: -10°C to +50°C (at full rated current) Protection Class: IP20 (standard for indoor use; additional external protection kits available for harsh environments) Cooling: Forced air cooling (fan inside the drive) Efficiency: Typically 97%, which helps reduce operating costs. Dimensions (H x W x D): Approx. 380 x 220 x 160 mm (varies by configuration) Weight: Approx. 5–7 kg Control Voltage: 24 V DC (for control and auxiliary circuits) Mounting: Panel or wall mountable (with standard mounting holes for easy installation) Communication Protocols: Modbus RTU Profibus DP DeviceNet (optional, depending on configuration) Built-in Application Macros: Simplifies installation and commissioning by providing predefined settings for various common applications (e.g., pumps, fans). Keypad: Integrated keypad for local programming and diagnostics with a digital display to show status and fault information.

Parameters: Model Number: ABB ACS510-01-05A6-4 Rated Output Power: 5.5 kW (approximately 7.5 HP) Input Voltage Range: 380–480 V, 3-phase power supply Rated Input Current: 12.6 A (at 380 V) Frequency Range: 0 to 500 Hz Control Method: V/f (Volts per Hertz) Control: Standard method for motor speed control. Sensorless Vector Control (SVC): Offers improved performance by providing precise torque and speed control without the need for a motor encoder. Motor Control: Suitable for controlling squirrel-cage motors in pumps, fans, compressors, and other variable torque applications. Ambient Temperature Range: -10°C to +50°C (at full rated current) Protection Class: IP20 (suitable for indoor environments; additional external kits available for outdoor or harsher environments) Cooling: Forced air cooling (fan inside the drive) Efficiency: Typically 97%, providing energy savings in motor-driven applications. Dimensions (H x W x D): Approx. 260 x 160 x 170 mm (varies by configuration) Weight: Approx. 4.5 kg Control Voltage: 24 V DC (for control circuitry) Mounting: Panel or wall mountable (with standard mounting holes for easy installation) Communication Protocols: Modbus RTU (standard communication for integration with PLCs and automation systems) Optional protocols for Profibus DP, DeviceNet, or Ethernet/IP (based on configuration) Keypad: Features an integrated keypad with a digital display for easy programming, status monitoring, and fault diagnostics. Built-in Application Macros: Pre-programmed settings for common applications such as fans, pumps, and conveyors for easy configuration and commissioning.

Parameters: Model Number: ABB ACS550-01-06A9-4 Rated Output Power: 3 kW (approximately 4 HP) Input Voltage Range: 380–480 V, 3-phase power supply Rated Input Current: 6.2 A (at 380 V) Frequency Range: 0 to 500 Hz Control Method: V/f (Volts per Hertz) Control: Basic method for motor speed control with smooth performance. Sensorless Vector Control (optional): Offers precise control of motor torque and speed without the need for additional sensors. Motor Control: Ideal for controlling squirrel-cage motors in both constant torque and variable torque applications. Ambient Temperature Range: -10°C to +50°C (at full rated current) Protection Class: IP20 (for indoor use; additional external kits are available for harsh environments) Cooling: Forced air cooling (fan inside the drive) Efficiency: Typically 97%, ensuring energy-efficient operation. Dimensions (H x W x D): Approx. 220 x 150 x 130 mm (varies by configuration) Weight: Approx. 2.5 kg Control Voltage: 24 V DC (for control and auxiliary circuits) Mounting: Panel or wall mountable (with standard mounting holes for easy installation) Communication Protocols: Modbus RTU (standard communication for integration with PLCs and other control systems) Optional protocols for Profibus DP, DeviceNet, or Ethernet/IP (depending on configuration) Keypad: Features an integrated keypad with a digital display for easy parameter setting, monitoring, and diagnostics. Built-in Application Macros: Simplifies the setup process with pre-configured settings for common applications like pumps, fans, and conveyors.

Parameters: Model Number: ABB ACS550-01-05A4-4 Rated Output Power: 2.2 kW (approximately 3 HP) Input Voltage Range: 380–480 V, 3-phase power supply Rated Input Current: 4.5 A (at 380 V) Frequency Range: 0 to 500 Hz Control Method: V/f (Volts per Hertz) Control: Standard method for controlling motor speed based on voltage and frequency ratio. Sensorless Vector Control (optional): Provides enhanced torque control and precision at low speeds, making it ideal for applications that require high performance. Motor Control: Suitable for controlling squirrel-cage motors in both constant torque and variable torque applications. Ambient Temperature Range: -10°C to +50°C (at full rated current) Protection Class: IP20 (suitable for indoor use; additional protection kits available for outdoor or harsh environments) Cooling: Forced air cooling (fan inside the drive) Efficiency: Typically 97%, ensuring energy savings in motor-driven systems. Dimensions (H x W x D): Approx. 220 x 150 x 130 mm (varies by configuration) Weight: Approx. 2.0–2.5 kg Control Voltage: 24 V DC (for control and auxiliary circuits) Mounting: Panel or wall mountable (with standard mounting holes for easy installation) Communication Protocols: Modbus RTU (for integration with PLCs and automation systems) Optional Profibus DP, DeviceNet, and Ethernet/IP for more advanced integration. Keypad: Integrated keypad with a digital display for easy parameter setting, monitoring, and diagnostics. Built-in Application Macros: Pre-programmed settings for pumps, fans, compressors, and conveyors, simplifying installation and commissioning.

SERVICE HOTLINE Grace +86 13600179521
Mail info@hongkongeasy.com jilineasyyi@outlook.com ADDRESS Unit 12, 20th Floor, Good View Commercial Centre, 2-16 Garden Street, Mong Kok, Hong Kong
Q Q: 615739355
吉林易择科技技术发展有限公司 吉ICP备2024020526号-1
js
0.864126s