Parameters: Model Number: ABB SACE F2S2500 R2500 PR1/P-LSIG 3P Rated Voltage: 400 V AC (Three-phase) Rated Current: 2500 A (adjustable) Frequency: 50/60 Hz Protection Type: Long-Time Protection (L): Adjustable from 0.7 to 1.0 times rated current for overload protection, preventing prolonged overcurrents that could damage equipment. Short-Time Protection (S): Adjustable from 3 to 10 times rated current, with a time delay, protecting against short-circuit conditions and ensuring the system's stability. Instantaneous Protection (I): Provides immediate disconnection for high fault currents during severe short-circuit events, protecting sensitive equipment. Ground Fault Protection (G): Ground fault protection (LSIG) detects leakage currents or ground faults, isolating the faulty circuit to prevent electrical hazards. Thermal Overload Protection: Protects motors from overheating by continuously monitoring the system's temperature and adjusting the protection accordingly. Breaking Capacity (Icu): 50 kA at 400 V, ensuring that the breaker can quickly interrupt high fault currents without causing damage to the system or components. Mounting Type: DIN rail or panel mount for easy integration into existing electrical systems, such as motor control centers (MCCs) or distribution boards. Degree of Protection: IP20 (suitable for indoor environments; optional external protection kits available for harsher, outdoor environments). Weight: Approx. 20–25 kg (depending on configuration and options). Dimensions (H x W x D): Approx. 500 x 300 x 200 mm (subject to configuration). Control Voltage: 24 V DC (external supply required for control and communication features). Modbus RTU Communication (Optional): Enables remote monitoring and diagnostics via PLC or SCADA systems, allowing for real-time system health tracking and fault detection. Auxiliary Contacts (Optional): Available for use with control systems for signaling faults, remote indication, or integration with safety systems
Parameters: Model Number: ABB E1N1250 R1250 PR121/P-LSI WMP 3P Rated Voltage: 400 V AC (Three-phase) Rated Current: 1250 A (adjustable) Frequency: 50/60 Hz Protection Type: Long-Time Protection (L): Adjustable from 0.7 to 1.0 times rated current for overload protection, ensuring protection against sustained overcurrents. Short-Time Protection (S): Adjustable from 3 to 10 times rated current, with a time delay, for short-circuit protection, preventing damage from transient overcurrents. Instantaneous Protection (I): Provides immediate disconnection for severe short-circuit conditions to protect sensitive equipment from high fault currents. Ground Fault Protection (G): Detects leakage currents or ground faults and isolates the faulty section, improving electrical safety. Thermal Overload Protection: Protects motors from overheating by monitoring the system’s temperature and preventing extended overcurrent conditions. Wide Motor Protection (WMP): Ensures adaptive protection tailored to motor applications, optimizing protection parameters based on specific motor types and operational conditions. Breaking Capacity (Icu): 50 kA at 400 V, ensuring the breaker can safely handle high fault currents and disconnect the system in fault conditions. Mounting Type: DIN rail or panel mount for easy integration into electrical control systems, such as motor control centers (MCCs) or distribution panels. Degree of Protection: IP20 (suitable for indoor environments; optional external protection kits available for harsh environments). Weight: Approx. 15–20 kg (depending on configuration). Dimensions (H x W x D): Approx. 400 x 250 x 180 mm (subject to configuration). Control Voltage: 24 V DC (external supply required for control and communication features). Modbus RTU Communication (Optional): For remote monitoring and diagnostics, enabling real-time system health checks and fault detection via PLC or SCADA systems. Auxiliary Contacts (Optional): Available for use in control systems, providing feedback and fault signaling to external systems.
Parameters: Model Number: ABB E4S4000 R4000 PR122/P-LSIG 4P 4000A Rated Voltage: 400 V AC (Four-pole, Three-phase system) Rated Current: 4000 A (adjustable) Frequency: 50/60 Hz Protection Type: Long-Time Protection (L): Adjustable from 0.7 to 1.0 times rated current for overload protection, preventing equipment damage from prolonged overcurrents. Short-Time Protection (S): Adjustable from 3 to 10 times rated current, with a time delay, to protect against short-circuit conditions and to avoid unnecessary trips. Instantaneous Protection (I): Provides instantaneous disconnection for high fault currents, ensuring fast protection against severe short-circuit conditions. Ground Fault Protection (G): Ground fault protection (LSIG) detects leakage currents or faults and isolates the faulty section, providing enhanced safety. Thermal Overload Protection: Continuously monitors the temperature of motors and equipment, adjusting protection to prevent overheating and ensure the longevity of the system. Breaking Capacity (Icu): 65 kA at 400 V, ensuring the breaker can interrupt high fault currents and safely clear faults without damaging the system. Mounting Type: DIN rail or panel mount, making it versatile for use in motor control centers (MCCs), distribution boards, and control panels. Degree of Protection: IP20 (suitable for indoor environments; external protection kits available for harsher, outdoor conditions). Weight: Approx. 50–60 kg (depending on configuration). Dimensions (H x W x D): Approx. 650 x 450 x 300 mm (varies with configuration). Control Voltage: 24 V DC (external supply for control and communication features). Modbus RTU Communication (Optional): Enables remote monitoring, diagnostics, and fault detection through PLC or SCADA systems, allowing real-time system status checks and fault tracking. Auxiliary Contacts (Optional): Available for use with control systems for signaling faults, status monitoring, or integration with safety systems.
Parameters: Model Number: ABB E1N1600 R400/800/1600 3/4P Rated Voltage: 400 V AC (Three-phase or Four-pole systems) Rated Current: 1600 A (adjustable, with different options for 400A, 800A, or 1600A) Frequency: 50/60 Hz Protection Type: Long-Time Protection (L): Adjustable from 0.7 to 1.0 times rated current for overload protection. Short-Time Protection (S): Adjustable from 3 to 10 times rated current, with a time delay, for short-circuit protection. Instantaneous Protection (I): Provides instantaneous disconnection for severe short-circuit conditions. Ground Fault Protection (G): Ground fault protection (LSI) detects leakage currents and isolates the faulty section, providing enhanced safety for the system. Thermal Overload Protection: Protects motors from overheating by monitoring the system's temperature and adjusting protection parameters accordingly. Breaking Capacity (Icu): 50 kA at 400 V, ensuring the breaker can handle high fault currents and quickly disconnect during fault events. Mounting Type: DIN rail or panel mount, making it easy to install in motor control centers (MCCs), distribution panels, and control systems. Degree of Protection: IP20 (suitable for indoor environments; optional external protection kits for harsh, outdoor conditions). Weight: Approx. 20-25 kg (depending on configuration). Dimensions (H x W x D): Approx. 500 x 300 x 200 mm (subject to configuration). Control Voltage: 24 V DC (external supply required for control and communication features). Modbus RTU Communication (Optional): Allows for remote monitoring and fault diagnostics via PLC or SCADA systems. Auxiliary Contacts (Optional): Available for use in control systems, providing feedback, signaling faults, or integrating with safety systems.
Parameters: Model Number: ABB E3S1250 R1250 PR122/P-LSI WMP 3P Rated Voltage: 400 V AC (Three-phase) Rated Current: 1250 A (adjustable) Frequency: 50/60 Hz Protection Type: Long-Time Protection (L): Adjustable from 0.7 to 1.0 times rated current for overload protection, preventing sustained overcurrents that could damage equipment. Short-Time Protection (S): Adjustable from 3 to 10 times rated current, with time delay, for short-circuit protection to handle fault conditions without unnecessary tripping. Instantaneous Protection (I): Provides instantaneous disconnection during severe short-circuit conditions to protect sensitive equipment. Ground Fault Protection (G): Ground fault protection (LSI) detects leakage currents or faults in the system and isolates the faulty section, improving safety. Thermal Overload Protection: Continuously monitors motor temperature to prevent overheating and ensure safe operation under various conditions. Wide Motor Protection (WMP): Provides enhanced protection against inrush currents and load fluctuations, optimizing the motor's protection under varying operational conditions. Breaking Capacity (Icu): 50 kA at 400 V, ensuring that the breaker can safely interrupt high fault currents and clear faults quickly without damage to the system. Mounting Type: DIN rail or panel mount, making it easy to integrate into motor control centers (MCCs), distribution boards, and electrical panels. Degree of Protection: IP20 (suitable for indoor environments; optional external protection kits for harsher conditions). Weight: Approx. 20–25 kg (depending on configuration). Dimensions (H x W x D): Approx. 500 x 300 x 200 mm (subject to configuration). Control Voltage: 24 V DC (external supply required for control and communication features). Modbus RTU Communication (Optional): Enables remote monitoring and diagnostics via PLC or SCADA systems, providing real-time system health tracking and fault detection. Auxiliary Contacts (Optional): Available for control systems, offering fault signaling and feedback to external systems.
Parameters: Model Number: ABB E3S2000 R2000 PR121/P-LSI 3P Rated Voltage: 400 V AC (Three-phase) Rated Current: 2000 A (adjustable) Frequency: 50/60 Hz Protection Type: Long-Time Protection (L): Adjustable from 0.7 to 1.0 times rated current for overload protection, ensuring that motors are not damaged by prolonged overcurrents. Short-Time Protection (S): Adjustable from 3 to 10 times rated current, with a time delay, for short-circuit protection to protect against fault conditions without causing unnecessary trips. Instantaneous Protection (I): Provides instantaneous disconnection in the event of severe short-circuit conditions, protecting sensitive equipment from high fault currents. Ground Fault Protection (G): Ground fault protection (LSI) detects leakage currents or faults in the system and isolates the faulty section to prevent damage and ensure safety. Thermal Overload Protection: The breaker monitors the temperature of the system and protects motors from overheating, reducing the risk of damage due to sustained overload conditions. Breaking Capacity (Icu): 65 kA at 400 V, ensuring the breaker can interrupt high fault currents and clear faults safely without damaging the system. Mounting Type: DIN rail or panel mount, making it easy to integrate into motor control centers (MCCs), distribution panels, and electrical control systems. Degree of Protection: IP20 (suitable for indoor environments; external protection kits available for harsh conditions). Weight: Approx. 45–50 kg (depending on configuration). Dimensions (H x W x D): Approx. 600 x 400 x 250 mm (subject to configuration). Control Voltage: 24 V DC (external supply required for control and communication features). Modbus RTU Communication (Optional): Enables remote monitoring and fault diagnostics via PLC or SCADA systems, providing real-time system health tracking. Auxiliary Contacts (Optional): Available for use in control systems to provide feedback, signaling faults, or integrating with safety systems.
Parameters: Model Number: ABB SACE Emax E2 2000A PR121/P 3P Rated Voltage: 400 V AC (Three-phase) Rated Current: 2000 A (adjustable settings) Frequency: 50/60 Hz Protection Type: Long-Time Protection (L): Adjustable from 0.7 to 1.0 times rated current for overload protection, helping prevent damage from prolonged overcurrents. Short-Time Protection (S): Adjustable from 3 to 10 times rated current, with a time delay, to protect against short-circuit conditions without unnecessary tripping. Instantaneous Protection (I): Provides instantaneous disconnection for severe short-circuit conditions, ensuring fast response to dangerous faults. Ground Fault Protection (G): Ground fault protection (PR) detects leakage currents or faults in the system and isolates the faulty section to ensure safety. Thermal Overload Protection: Monitors the system’s temperature to protect motors and transformers from overheating. Breaking Capacity (Icu): 70 kA at 400 V, ensuring safe interruption of high fault currents. Mounting Type: DIN rail or panel mount for easy installation into motor control centers (MCCs), distribution boards, and electrical panels. Degree of Protection: IP20 (suitable for indoor use; external kits available for harsher conditions). Weight: Approx. 50–60 kg (depending on configuration). Dimensions (H x W x D): Approx. 650 x 500 x 250 mm (subject to configuration). Control Voltage: 24 V DC (external supply for control and communication features). Communication Protocol: Modbus RTU, Profibus, and Ethernet (optional) for remote monitoring, diagnostics, and integration into larger control systems. Auxiliary Contacts (Optional): Available for integration into control systems for signaling faults and system status updates.
Parameters: Model Number: ABB SACE Emax E2 2000A PR122/P-LSI 3P Rated Voltage: 400 V AC (Three-phase) Rated Current: 2000 A (adjustable) Frequency: 50/60 Hz Protection Type: Long-Time Protection (L): Adjustable from 0.7 to 1.0 times rated current for overload protection, protecting against prolonged overcurrents that can damage equipment. Short-Time Protection (S): Adjustable from 3 to 10 times rated current, with a time delay, for short-circuit protection. This helps protect the system from fault conditions while avoiding unnecessary trips. Instantaneous Protection (I): Provides instantaneous disconnection in case of severe short-circuit conditions, protecting sensitive equipment from high fault currents. Ground Fault Protection (G): Ground fault protection (LSI) detects leakage currents and isolates the faulty section of the system, improving safety and reducing the risk of electrical hazards. Thermal Overload Protection: Protects against overheating by continuously monitoring the system's temperature and adjusting protection parameters accordingly. Breaking Capacity (Icu): 70 kA at 400 V, allowing for safe interruption of high fault currents, preventing damage to the system and connected equipment. Mounting Type: DIN rail or panel mount, making it easy to install in motor control centers (MCCs), distribution panels, and electrical control systems. Degree of Protection: IP20 (suitable for indoor applications; external protection kits can be added for harsher environments). Weight: Approx. 45–55 kg (depending on configuration). Dimensions (H x W x D): Approx. 650 x 500 x 250 mm (subject to configuration). Control Voltage: 24 V DC (external supply required for control and communication features). Communication Protocols: Modbus RTU, Profibus, and Ethernet for real-time remote monitoring, diagnostics, and control via PLC or SCADA systems. Auxiliary Contacts (Optional): Available for integrating into control systems for signaling faults and providing system status updates.
Parameters: Model Number: ABB E3S2000 R2000 PR121/P-LSI WHR 3P Rated Voltage: 400 V AC (Three-phase) Rated Current: 2000 A (adjustable) Frequency: 50/60 Hz Protection Type: Long-Time Protection (L): Adjustable from 0.7 to 1.0 times rated current for overload protection, which helps prevent damage due to prolonged overcurrents. Short-Time Protection (S): Adjustable from 3 to 10 times rated current, with a time delay, to provide short-circuit protection without unnecessarily tripping the system. Instantaneous Protection (I): Provides instantaneous disconnection in the event of a severe short-circuit, protecting sensitive equipment from high fault currents. Ground Fault Protection (G): Ground fault protection (LSI) detects leakage currents or faults in the system and isolates the faulty section for safety. Thermal Overload Protection: Continuously monitors the system's temperature, protecting the motor from overheating during overload conditions. Wide Motor Protection (WHR): Provides enhanced protection for motors, helping to handle high inrush currents and load fluctuations that are typical in motor-driven systems. Breaking Capacity (Icu): 65 kA at 400 V, ensuring safe interruption of high fault currents without damage to the system. Mounting Type: DIN rail or panel mount, making it easy to install in motor control centers (MCCs), distribution boards, and electrical control systems. Degree of Protection: IP20 (suitable for indoor environments; external protection kits available for harsh conditions). Weight: Approx. 40–50 kg (depending on configuration). Dimensions (H x W x D): Approx. 600 x 400 x 250 mm (subject to configuration). Control Voltage: 24 V DC (external supply required for control and communication features). Communication Protocols: Modbus RTU, Profibus, and Ethernet for remote monitoring, diagnostics, and integration with PLC or SCADA systems. Auxiliary Contacts (Optional): Available for integration into control systems to signal faults and provide system status updates.
Parameters: Model Number: ABB E3N3200 R3200 PR121/P-LSI FHR 3P Rated Voltage: 400 V AC (Three-phase) Rated Current: 3200 A (adjustable) Frequency: 50/60 Hz Protection Type: Long-Time Protection (L): Adjustable from 0.7 to 1.0 times rated current for overload protection, which prevents equipment from damage due to prolonged overcurrent conditions. Short-Time Protection (S): Adjustable from 3 to 10 times rated current, with a time delay, for short-circuit protection, providing immediate protection in the event of faults while allowing for motor startup. Instantaneous Protection (I): Provides instantaneous disconnection in the case of severe short-circuit conditions, protecting sensitive equipment from high fault currents. Ground Fault Protection (G): Ground fault protection (LSI) detects leakage currents or faults in the system and isolates the faulty section to prevent further damage or safety hazards. Thermal Overload Protection: Monitors the temperature of the system to prevent overheating, which could cause damage to motors or other components. Flexible High Resistance (FHR): Provides enhanced protection for motor-driven systems, allowing for adjustment to varying inrush currents and fluctuating load conditions that are common in motor-driven applications. Breaking Capacity (Icu): 70 kA at 400 V, ensuring safe interruption of high fault currents without causing damage to the system. Mounting Type: DIN rail or panel mount, making it easy to integrate into motor control centers (MCCs), distribution panels, and electrical control systems. Degree of Protection: IP20 (suitable for indoor environments; external kits available for harsher environments). Weight: Approx. 50–60 kg (depending on configuration). Dimensions (H x W x D): Approx. 650 x 500 x 250 mm (subject to configuration). Control Voltage: 24 V DC (external supply required for control and communication features). Communication Protocols: Modbus RTU, Profibus, and Ethernet for remote monitoring, diagnostics, and integration with PLC or SCADA systems. Auxiliary Contacts (Optional): Available for integration into control systems to signal faults and provide system status updates.
Parameters: Model Number: ABB E1B800 R800 PR121/P-LSI WHR 3P Rated Voltage: 400 V AC (Three-phase) Rated Current: 800 A (adjustable) Frequency: 50/60 Hz Protection Type: Long-Time Protection (L): Adjustable from 0.7 to 1.0 times rated current for overload protection, preventing damage from sustained overcurrents. Short-Time Protection (S): Adjustable from 3 to 10 times rated current with a time delay to provide protection against short-circuit conditions. Instantaneous Protection (I): Offers instantaneous disconnection for severe short-circuit conditions, protecting the system from high fault currents. Ground Fault Protection (G): Ground fault protection (LSI) detects leakage currents and isolates the faulty section, preventing hazards and ensuring safety. Thermal Overload Protection: Monitors the system’s temperature to protect equipment from overheating during prolonged overload conditions. Wide High Resistance (WHR): Designed for motor-driven systems, this feature helps protect against high inrush currents and fluctuating load conditions, which are typical in motors during startup or load changes. Breaking Capacity (Icu): 65 kA at 400 V, ensuring that high fault currents are safely interrupted without damaging the system. Mounting Type: DIN rail or panel mount for easy installation into motor control centers (MCCs), distribution panels, and electrical control systems. Degree of Protection: IP20 (suitable for indoor applications; external protection kits can be added for harsh environments). Weight: Approx. 30–40 kg (depending on configuration). Dimensions (H x W x D): Approx. 600 x 400 x 250 mm (subject to configuration). Control Voltage: 24 V DC (external supply required for control and communication features). Communication Protocols: Modbus RTU, Profibus, and Ethernet for remote monitoring, diagnostics, and integration with PLC or SCADA systems. Auxiliary Contacts (Optional): Available for integration into control systems for signaling faults and providing system status updates.
Parameters: Model Number: ABB 1SDA038290R1 Operating Voltage: 110/120V AC Relay Type: Electromechanical relay Relay Contact Configuration: Single-pole (SP) or Double-pole (DP) (specifics would depend on internal contacts; confirm with product datasheet for exact configuration). Rated Current: Up to 10 A (depending on application; typical for industrial control systems). Frequency: 50/60 Hz Coil Resistance: Typically in the range of 100 to 300 ohms, depending on the exact specifications of the relay coil. Switching Voltage: 110/120V AC Contact Rating: Typically 10A at 120V AC (resistive load), with different ratings available for inductive or capacitive loads. Mounting Type: DIN rail mountable or panel mountable, depending on installation preferences. Protection: Typically comes with internal overload protection, designed to safeguard the connected circuits from overcurrent conditions. Use Case: Suitable for control and automation applications, motor control, switching circuits, HVAC systems, and lighting circuits in industrial environments. Control Type: On/off control or timed relay control, depending on configuration.