Industrial Controller
All product are in stock,guaranteed delivery within 3-7 days.
Infinite Innovation, the Future of Industrial Control Systems
Infinite Innovation, the Future of Industrial Control Systems
PRODUCT POSITION:HOMEPRODUCT—XT1S160 TMD100-1000 FF 3P
XT1S160 TMD100-1000 FF 3P
Key Features Circuit Breaker Type: Automatic molded case circuit breaker with thermal‑magnetic trip unit (TMD). Number of Poles: 3P (three‑phase protection). Mounting: Fixed‑mount with front access terminals for easy installation. Frame Size: 160 A — breaker frame rating. Trip Unit Range: Designed for adjustable protection settings 100–1000 A within the thermal‑magnetic release. Application: Protects circuits from overloads and short circuits in low‑voltage distribution and load feeder systems. Electrical Ratings Rated Operational Voltage: Up to 690 V AC (low‑voltage AC distribution). Rated Insulation Voltage (Ui): Typically 800 V. Rated Impulse Withstand Voltage (Uimp): 8 kV — ability to withstand high transient voltages. Rated Uninterrupted Current (Iu): 160 A — conductor thermal rating for the breaker frame. Rated Current Setting (In): 100 A — nominal current trip setting within the adjustable range. Instantaneous Short‑Circuit Setting (Ii): 1000 A — magnetic threshold for short‑circuit trip. Service Short‑Circuit Breaking Capacity (Ics): High interrupt current capability rated for multiple kA values across common system voltages (e.g., higher at lower voltages, lower at high AC system voltages). Rated Frequency: 50/60 Hz compatibility. Mechanical & Durability Mechanical Durability: Designed for high numbers of switching operations over its service life. Electrical Endurance: Rated for many load make/break cycles under rated conditions. Thermal‑Magnetic Protection: Combines long‑term overload protection (thermal) with near‑instantaneous reaction to very high fault currents (magnetic). Environmental & Operational Operating Conditions: Suitable for industrial ambient environments typical of control panels, switchboards, and distribution enclosures. Installation Type: Panel‑mounted with access from the front for wiring and maintenance. Typical Applications Branch and feeder protection in industrial and commercial power distribution systems. Motor feeder circuit protection and equipment isolation. Control cabinets requiring circuit protection up to 160 A. Safety interlocks and emergency cutoff circuits requiring reliable overcurrent response.
DESCRIBE
The ABB XT1S 160 TMD 100‑1000 3P F F is a 3‑pole molded case circuit breaker (MCCB) from ABB’s Tmax XT1 series. It provides reliable overcurrent protection for low‑voltage electrical systems by combining thermal overload protection with instantaneous magnetic short‑circuit protection in a compact, fixed‑mount design with front terminals. It is suited for industrial and commercial power distribution, control panels, and machinery safety circuits.
SERVICE HOTLINE Grace +86 13600179521
Mail jilineasyyi@outlook.com ADDRESS Unit 12, 20th Floor, Good View Commercial Centre, 2-16 Garden Street, Mong Kok, Hong Kong
Q Q: info@hongkongeasy.com
吉林易择科技技术发展有限公司 吉ICP备2024020526号-1
js