Technical Parameters
Parameter / Feature Specification / Detail
Series / Model RT6 Safety Relay — 115 AC version (2TLA010026R0400)
Supply (Coil) Voltage 115 V AC (A1–A2)
Input Channels 1 or 2 (single- or dual‑channel configuration)
Safety Inputs Supported Emergency stop, safety mats/edges, light curtains/beams, safety switches / interlocks, gates/doors, enabling devices, contact strips, etc.
Reset Modes Manual supervised reset or Automatic reset (configurable)
Safety Output Contacts 3 × NO (normally open) + 1 × NC (normally closed) — total 4 safety‑rated contacts
Contact Rating / Switching Capacity (Resistive Load) 6 A @ up to 250 V AC (resistive) / up to 1500 VA maximum
Inductive Load Capacity e.g. AC‑15: 2 A @ 240 V AC; DC‑13: 1 A @ 24 V DC (when used on DC)
Maximum Total Switching Capacity 12 A distributed across all outputs
Minimum Load Capacity 10 mA @ 10 V (if contact load does not exceed 100 mA)
Auxiliary / Information Outputs Two voltage‑free transistor “info” outputs (Y14, Y24) — for status signalling (not to be used as safety outputs)
Auxiliary Output Supply / Load External +5 V … +30 V DC supply; max 15 mA per output; max voltage drop ~2.4 V at full load
Mounting / Terminals 35 mm DIN‑rail mounting; plug‑in / screw‑clamp terminal blocks
Enclosure / Protection Housing: IP40; Terminals: IP20
Product Dimensions Width: ~45 mm; Height: ~84 mm; Depth: ~120 mm
Weight (net) ~ 0.485 kg
Mechanical Endurance > 10⁷ operations (long lifetime)
Safety Category / Standard Compliance Safety Category 4 / Performance Level e (when properly wired, dual‑channel, with monitoring) — compliant with safety‑relay standards for machine safety
The RT6 115 AC Safety Relay (2TLA010026R0400) is a universal safety relay for industrial safety‑circuit use. It can monitor safety devices like emergency‑stop buttons, safety mats/edges, safety switches/interlocks, light curtains/beams, safety‑switch sensors, enabling devices, gates/doors, or contact strips — either in single‑channel or dual‑channel mode. The relay supports manual supervised reset or automatic reset, and includes safety‑rated relay outputs plus auxiliary “information” outputs and LED status indication. It is DIN‑rail mountable and designed to integrate into control panels to supervise and switch safety circuits reliably.