Specifications
General
Type: Differential Pressure Transmitter
Series: ABB 266 GSH
Output: 4–20 mA, two-wire with HART communication
Sensor Technology: Digital capacitive differential sensor with temperature compensation
Measurement Performance
Reference Accuracy: ±0.04% of span (depending on calibration and range)
Repeatability: ±0.02% of span
Turn-Down Ratio: Up to 100:1
Response Time: <100 ms
Long-Term Stability: ±0.1% URL over 10 years
Pressure Ratings
Differential Pressure Range: According to CKBNA1 sensor selection
Static Pressure Rating: High static pressure capability (per GSH design)
Proof Pressure: 1.5 × static rating
Overpressure Protection: Integrated mechanical system
Materials & Construction
Wetted Parts: Stainless steel / Hastelloy / optional alloys (per CKBNA1)
Fill Fluid: Silicone oil or inert fluid
Housing: Aluminum or stainless steel (per model configuration)
Process Connections: Flanges or threaded high-pressure adapters
Electrical & Communication
Power Supply: 10.5–45 VDC
Signal: 4–20 mA + HART digital
Load Resistance (HART): ≤600 Ω
Local Configuration: Optional push-button or LCD interface
Environmental Conditions
Electronics Operating Temperature: –40 to +85 °C
Process Temperature: Based on sensor and fill fluid
Humidity: 0–100% RH, non-condensing
Ingress Protection: IP67 / IP68 depending on housing and electrical entry
Vibration Resistance: Up to 10 g, 10–2000 Hz
Certifications / Compliance
Explosion Protection: Ex ia / Ex d / Ex nA options depending on configuration
Compliance: ATEX, IECEx, PED, CE
EMC / Surge Protection: Industrial-grade standards
The ABB 266GSH (CKBNA1 configuration) is a high-performance differential pressure transmitter from ABB’s 266 series, designed for reliable and precise measurement of differential pressure in industrial process applications. The 266GSH features ABB’s proven digital capacitive sensor technology, offering excellent accuracy, long-term stability, and repeatability even under harsh conditions.