Industrial Controller
All product are in stock,guaranteed delivery within 3-7 days.
Infinite Innovation, the Future of Industrial Control Systems
Infinite Innovation, the Future of Industrial Control Systems
PRODUCT POSITION:HOMEPRODUCT—GSH204 AC-C63/0.03
GSH204 AC-C63/0.03
Technical Specifications / Parameters Parameter Specification Manufacturer Type Code GSH204 AC-C63/0.03 Brand / Series ABB System PRO M compact® (GSH200 Series - RCBO) Device Type Residual Current Circuit Breaker with Overcurrent Protection (RCBO) Number of Poles 4-Pole (4P) (Protects all three phases and the neutral) Rated Current (In) 63 A (This is the overcurrent protection rating. The device provides both overload and short-circuit protection up to this current.) Tripping Characteristic (Overcurrent) C Curve (Instantaneous magnetic tripping range: 5In to 10In, i.e., 315A to 630A). Rated Residual Operating Current (IΔn) 30 mA (0.03A) (High sensitivity, providing protection against direct contact / electric shock). Residual Current Type Type AC: Sensitive to sinusoidal alternating residual currents only. Rated Operational Voltage (Ue) 400 V AC (3P+N~) Rated Breaking Capacity (Icn) 6 kA (IEC/EN 61009-1) Mechanical Life ≥ 20,000 operations Test Button Yes. A built-in "T" button to test the RCD functionality. Mounting DIN Rail Mounting (35 mm symmetrical rail, EN 60715) Module Width 72 mm (4 modules) Standards Compliance IEC/EN 61009-1 (RCBO standard), IEC/EN 60898-1 (for MCB part), CE, CCC, etc. Terminals Cage Clamp Terminal for all poles. Connectable Conductors Rigid/Flexible Copper: 10 - 35 mm² (suitable for 63A rating). Ambient Temperature Range -25°C to +55°C (for calibration)
DESCRIBE
The ABB GSH204 AC-C63/0.03 is a 4-pole, 63A, Type AC, C-curve Residual Current Circuit Breaker with Overcurrent Protection (RCBO). This is a combined protection device that integrates the functions of a miniature circuit breaker (MCB) and a residual current device (RCD) into a single unit. It provides comprehensive protection for three-phase circuits (with neutral) against: 1) overloads, 2) short-circuits, and 3) earth leakage currents that could cause electric shock or fire. The "C" curve indicates its magnetic tripping characteristic for short-circuit protection, suitable for circuits with moderate inrush currents.
SERVICE HOTLINE Grace +86 13600179521
Mail jilineasyyi@outlook.com ADDRESS Unit 12, 20th Floor, Good View Commercial Centre, 2-16 Garden Street, Mong Kok, Hong Kong
Q Q: info@hongkongeasy.com
吉林易择科技技术发展有限公司 吉ICP备2024020526号-1