Model Number P0914LV
Product Type Gauge Pressure Transmitter
Pressure Type Gauge Pressure (pressure relative to atmospheric pressure)
Sensor Technology Advanced high-stability sensor (e.g., silicon resonant or capacitive)
Output Signal 4-20 mA analog output with HART® Protocol for digital communication.
Accuracy High accuracy. For low-pressure "LV" models, this is often ±0.075% of the Upper Range Limit (URL) or calibrated span.
Pressure Range (URL) The "LV" code is critical and typically indicates a low pressure range. The "14" in P0914LV often correlates to a specific range, such as 0-14 kPa (0-2 psi, 0-56 inches of water column).
Process Connection Low-pressure ports, often 1/4" NPT or similar, suitable for low-pressure gases.
Wetted Parts Material 316L Stainless Steel is standard.
Power Supply Standard 2-wire, 12-45 VDC loop-powered operation.
Operating Temperature Ambient: -40°C to +85°C (-40°F to 185°F). Process: Dependent on seal options.
Protection Rating NEMA 4X / IP67 (weatherproof and corrosion-resistant).
The Foxboro P0914LV is a gauge pressure transmitter from the Foxboro I/A Series. It is engineered for highly accurate and stable measurement of pressure in liquids, gases, and steam.