The Schneider Electric EZD400E represents a high-performance, compact solution within the EZD series of molded case circuit breakers. Designed specifically for 400 Ampere applications, this 4-pole (3-phase + neutral) MCCB delivers robust circuit protection for main distribution boards, sub-distribution panels, and industrial power systems.
Specifications
Category Technical Specifications
Basic Identification
Manufacturer & Series Schneider Electric, EZD Series
Complete Model Designation EZD400E 4P 400A
Product Type Molded Case Circuit Breaker (MCCB)
Standards Compliance IEC 60947-2, GB 14048.2, CE Certified
Electrical Ratings
Number of Poles 4-Pole (L1, L2, L3, N)
Frame Size E Frame
Rated Operational Current (Iu/Ir) 400 Amperes
Rated Insulation Voltage (Ui) 1000V AC
Rated Operational Voltage (Ue) 690V AC (50/60 Hz)
Rated Frequency 50/60 Hz
Breaking Capacity
Ultimate Breaking Capacity (Icu) 50kA at 400/415V AC (Standard)
65kA at 400/415V AC (High-breaking version)
Service Breaking Capacity (Ics) 100% of Icu (Ics = Icu)
Rated Short-Time Withstand Current (Icw) Typically 25kA for 1 second (varies by specific model)
Protection Characteristics
Overload Protection (L) Adjustable: (0.7-1.0) x In ±10% (Electronic version)
Fixed thermal protection (Thermal-Magnetic version)
Short-Circuit Protection (I) Adjustable: (1.5-10) x In ±15% (Instantaneous)
Fixed magnetic trip (Thermal-Magnetic version)
Trip Unit Options TM-D: Fixed thermal-magnetic
E/Micrologic: Electronic, adjustable with digital display
Mechanical & Physical Specifications
Mounting DIN Rail Mounting (35mm symmetrical) or Fixed Mounting
Electrical Connections Front or Rear terminals
Screw-type terminals for copper/aluminum cables
Busbar connection possible
Width Approximately 143mm (4-pole)
Weight Approximately 2.5-3.0 kg (depending on accessories)
Mechanical Durability 10,000 operations minimum
Electrical Durability 3,000 operations at rated current
Environmental Specifications
Operating Temperature -25°C to +70°C (Derating may apply above 40°C)
Storage Temperature -40°C to +85°C
Pollution Degree Degree 3
Installation Altitude Up to 2000m without derating
Protection Degree (IP Rating) IP20 (front panel mounted)
Accessories (Common Options)
Auxiliary Contacts OF, SDE, OF+SDE, alarm contact
Shunt Trip 24V AC/DC, 48V AC/DC, 110V AC, 220V AC/DC
Under-Voltage Release Available for various voltage ratings
Motor Operator Manual or remote operation mechanism
Terminal Covers For increased safety and IP rating
Locking Devices Padlock provisions, locking handles
Interlocks Mechanical interlock kits for multiple breakers