Key Features:
8mm stainless steel probe with M10×1 threading
0.5-2.5mm measuring range (8mV/µm sensitivity)
Wide frequency response (0-10kHz)
IP67 environmental protection
MIL-spec threaded connector
Technical Specifications:
Power supply: -18 to -24VDC (±10%)
Output signal: -2 to -18VDC
Operating temperature: -40°C to +100°C
±1% linearity across full range
5m standard cable (extendable to 300m)
Performance Highlights:
±0.5µm repeatability
100 bar pressure rating
500N axial load capacity
NIST-traceable calibration available
Typical Applications:
Industrial pump monitoring
Steam turbine shaft vibration
Compressor rotor position
Paper manufacturing equipment
General rotating machinery
Certifications:
CE and RoHS compliant
Meets API 670 (4th Ed.) and ISO 7919
ATEX option available
Installation Notes:
Requires carbon steel targets (AISI 4140 recommended)
20-30N·m mounting torque
Proper grounding required for optimal performance
1. General Specifications
Parameter Specification
Model PR6423/010-001
Type Industrial Eddy Current Proximity Sensor
Application Shaft Vibration & Position Monitoring
Standards API 670 (4th Ed.), ISO 7919
Certifications CE, RoHS (ATEX Optional)
2. Sensor Specifications
Feature Details
Probe Diameter 8 mm
Measuring Range 0.5 to 2.5 mm
Sensitivity 8 mV/µm ±5%
Frequency Response 0 to 10 kHz (±3 dB)
Linear Range ±0.8 mm from Electrical Null
Target Material Carbon Steel (AISI 4140 Recommended)
3. Electrical Specifications
Parameter Value
Power Supply -18 to -24 VDC (±10%)
Output Signal -2 to -18 VDC
Cable Length 5 m Standard (Extendable to 300 m)
Connector MIL-C-5015 Threaded
Current Draw <15 mA
4. Environmental Ratings
Condition Rating
Operating Temp. -40°C to +100°C
Ingress Protection IP67
Housing Material Stainless Steel 316
Pressure Rating 100 bar (1450 psi)
5. Mechanical Specifications
Attribute Details
Thread Standard M10×1
Mounting Torque 20-30 N·m
Weight 400 g (Probe Assembly)
Axial Load 500 N Maximum
6. Performance Metrics
Metric Value
Linearity ±1% of Full Scale
Repeatability ±0.5 µm
Temp. Coefficient ±0.05%/°C
7. System Components
Standard Package: