Key Features: Signal conditioning for eddy current probes and velocity sensors Galvanic isolation between channels (250VAC) Wide frequency response (DC to 15kHz) DIN rail or panel mounting options IP65-rated enclosure for harsh environments Technical Highlights: Screw terminal connections for secure wiring Built-in noise filtering for signal integrity Supports cable runs up to 500 meters Wide operating temperature range (-40°C to +85°C) Typical Applications: Integration with EPRO 9000 series monitors Turbine and compressor monitoring systems Industrial machinery protection installations Vibration measurement signal conditioning Compliance: Meets IEC 61000 EMC standards RoHS compliant Optional ATEX/IECEx versions available
DESCRIBE
General Specifications
Model: CON 011/915-040

Type: Signal conditioning & connection interface

Application: Vibration monitoring system integration

Compatibility: Designed for EPRO 9000 series monitoring modules

Standards: IEC 61000 (EMC), RoHS compliant

Electrical Characteristics
Input Channels:

Accepts signals from eddy current probes (8mm/11mm)

Compatible with velocity sensors (4–20 mA)

Signal Conditioning:

Impedance matching for long cable runs

Noise filtering (built-in RFI suppression)

Frequency Range: DC – 15 kHz (-3 dB)

Connection & Wiring
Terminal Type: Screw terminals (spring cage optional)

Cable Support:

Shielded twisted pair (recommended)

Max cable length: 500m (with proper shielding)

Isolation: Galvanic isolation between channels (250 VAC)

Environmental Ratings
Operating Temperature: -40°C to +85°C

Storage Temperature: -50°C to +100°C

Humidity: 5–95% RH (non-condensing)

Enclosure Rating: IP65 (dust/water resistant)

Mechanical Specifications
Housing Material: Flame-retardant polycarbonate

Mounting: DIN rail (TS35) or panel mount

Dimensions: 90 × 60 × 30 mm (W×H×D)

Weight: ~200 g

Safety & Certifications
Electrical Safety: 3000 VAC isolation test voltage

EMC: EN 61326-1 (industrial immunity)

Hazardous Area: Optional ATEX/IECEx certification (model-specific)

Typical Applications
Signal routing for EPRO vibration monitors (e.g., 9200 series)

Sensor interface in turbines, compressors, and pumps

Noise reduction in industrial EMI environments