Model Foxboro ICP10-T2001E-M2L1A3T Type Pressure Transmitter (Gauge/Absolute) Measurement Range 0-200 psi (e.g., "T200" may indicate 0-200 psi range) Output Signal 4-20 mA DC with HART® Protocol Accuracy ±0.25% of span (typical for ICP10 series) Power Supply 12-42 V DC (loop-powered) Process Connection 1/2" NPT Female (standard) Wetted Materials 316L Stainless Steel diaphragm and body Housing Rating NEMA 4X (IP66) Ambient Temperature -40°C to +85°C (-40°F to +185°F) Process Temperature -40°C to +120°C (-40°F to +248°F) Protocol HART® 7 Adjustable Turndown Up to 10:1 Certifications CE, RoHS (may vary by region) Electrical Connection 1/2" NPT conduit (as indicated by suffix)

Model Foxboro IMT25-IEBTB10N-B Type Multi-Variable Pressure Transmitter (DP, Static Pressure, Temperature) Measurement Range Differential Pressure (DP): 0-10 inH₂O (e.g., "10N" indicates 10 inH₂O span) Static Pressure: Up to 3600 psi (dependent on model variant) Temperature: Integrated RTD or via external sensor Output Signal 4-20 mA DC with HART® or FOUNDATION™ Fieldbus digital protocol Accuracy DP: ±0.04% of span; Static Pressure: ±0.1% of URL; Flow: ±0.5% of rate (typical) Power Supply 10.5-42 V DC (loop-powered for HART); 9-32 V DC (Fieldbus) Process Connection 1/2" NPT or flanged (e.g., 1/4" NPT for HP/LP sides) Wetted Materials Hastelloy C-276 diaphragm and seals (standard for corrosive environments) Housing Rating NEMA 4X (IP66) Ambient Temperature -40°C to +85°C (-40°F to +185°F) Process Temperature -40°C to +120°C (-40°F to +248°F) Protocol HART® 7 or FOUNDATION™ Fieldbus Adjustable Turndown Up to 100:1 Certifications SIL 2/3, ATEX, IECEx, CE Special Features Integrated flow computation, diagnostics, temperature compensation

Model Foxboro IMT25-PEATB10N-B Type Multi-Variable Pressure Transmitter (DP, Static Pressure, Temperature) Measurement Range Differential Pressure (DP): 0-10 inH₂O (e.g., "10N" indicates 10 inH₂O span) Static Pressure: Up to 3600 psi (dependent on model variant) Temperature: Integrated RTD or via external sensor Output Signal 4-20 mA DC with HART® or FOUNDATION™ Fieldbus digital protocol Accuracy DP: ±0.04% of span; Static Pressure: ±0.1% of URL; Flow: ±0.5% of rate (typical) Power Supply 10.5-42 V DC (loop-powered for HART); 9-32 V DC (Fieldbus) Process Connection 1/2" NPT or flanged (e.g., 1/4" NPT for HP/LP sides) Wetted Materials Hastelloy C-276 diaphragm and seals (standard for corrosive environments) Housing Rating NEMA 4X (IP66) Ambient Temperature -40°C to +85°C (-40°F to +185°F) Process Temperature -40°C to +120°C (-40°F to +248°F) Protocol HART® 7 or FOUNDATION™ Fieldbus Adjustable Turndown Up to 100:1 Certifications SIL 2/3, ATEX, IECEx, CE Special Features Integrated flow computation, diagnostics, temperature compensation

Model Foxboro BY3R873RS-BTWFGZ Type Pressure Transmitter (e.g., Gauge/Absolute/Differential) Measurement Range Customized (e.g., 0-1000 psi or other; "BTW" may indicate range code) Output Signal 4-20 mA DC with HART® Protocol Accuracy ±0.065% to ±0.1% of span (typical for 873 series) Power Supply 10.5-42 V DC (loop-powered) Process Connection 1/2" NPT or flanged (material: stainless steel or alloy) Wetted Materials Likely 316L Stainless Steel or Hastelloy (e.g., "FGZ" may specify materials) Housing Rating NEMA 4X (IP66) Ambient Temperature -40°C to +85°C (-40°F to +185°F) Process Temperature -40°C to +120°C (-40°F to +248°F) Protocol HART® 7 Certifications ATEX, IECEx, SIL 2/3 (depending on configuration) Calibration Factory calibrated to customer specifications

Model Foxboro HHT-AAEFNB Style-B Type Handheld Terminal (HHT) / Configurator Compatibility Foxboro field instruments (e.g., pressure/flow transmitters) Communication Protocols HART® (primary), potentially FOUNDATION™ Fieldbus or other protocols Display LCD screen (likely backlit for low-light environments) Keypad Sealed, ruggedized keys for use in harsh conditions Power Supply Rechargeable battery (e.g., Li-ion or NiMH) with AC adapter Battery Life 8-12 hours (typical per charge) Connectivity Electrical connections: 4-20 mA loop integration via test leads or connectors Operating Temperature -10°C to 50°C (14°F to 122°F) (field-use range) Enclosure Rating IP54 or higher (dust and water resistant) Software Features Device configuration, calibration, diagnostics, loop tests, data logging Certifications ATEX, IECEx (if rated for hazardous areas) Dimensions & Weight Compact and lightweight for portability (e.g., ~200-300g)

Model Foxboro FEM100 Type Fieldbus Electronic Module (FOUNDATION™ Fieldbus H1) Compatibility Foxboro I/A Series DCS (requires FMM chassis or compatible fieldbase) Protocol Support FOUNDATION™ Fieldbus H1 (IEC 61158-2) Number of Channels Typically 1 or 2 Fieldbus segments per module (varies by configuration) Power Supply 24 V DC (via chassis or external fieldbus power supply) Segment Power Provides conditioned power to Fieldbus segments (e.g., 19-23 V DC) Isolation 1500 V AC (channel-to-channel and channel-to-system) Communication Speed 31.25 kbit/s (standard Fieldbus H1 rate) Max Devices per Segment Up to 16 Fieldbus devices per segment Operating Temperature 0°C to 60°C (32°F to 140°F) Redundancy Support Yes (optional redundant configuration) Diagnostics LED status indicators for power, communication, and faults Certifications ATEX, IECEx, CE (depending on installation and region)

Model Foxboro IMT25-PEATB10N-B Type Multi-Variable Pressure Transmitter (Pressure/DP/Flow) Measurement Range Differential Pressure (DP): 0-10 inH₂O to 0-2000 psi (varies by code) Static Pressure: Up to 3600 psi (depending on model) Output Signal 4-20 mA DC with HART® or FOUNDATION™ Fieldbus digital protocol Accuracy DP: ±0.04% of span (typical); Static Pressure: ±0.1% of URL Power Supply 10.5-42 V DC (loop-powered for HART); 9-32 V DC (Fieldbus) Process Connection 1/2" NPT or flanged (e.g., 1/4" NPT for HP/LP sides) Wetted Materials Stainless Steel (316L), Hastelloy C-276, or other alloys (depending on variant) Housing Rating NEMA 4X (IP66) Ambient Temperature -40°C to +85°C (-40°F to +185°F) Process Temperature -40°C to +120°C (-40°F to +248°F) Protocol HART® 7 or FOUNDATION™ Fieldbus Adjustable Turndown Up to 100:1 Certifications SIL 2/3, ATEX, IECEx, CE Special Features Integrated flow computation, diagnostics, and temperature compensation

Model Foxboro P0903CW Rev-0C Type Pressure Transmitter (Gauge/Absolute) Measurement Range Likely 0-100 psi or similar (e.g., "03" in P0903 may indicate range code) Output Signal 4-20 mA DC with HART® Protocol Accuracy ±0.065% to ±0.1% of span (typical for Foxboro transmitters) Power Supply 10.5-42 V DC (loop-powered) Process Connection 1/2" NPT Female or Flanged (material: Hastelloy C-276) Wetted Materials Diaphragm: Hastelloy C-276; Seals: Viton® or PTFE (corrosion-resistant) Housing Rating NEMA 4X (IP66) Ambient Temperature -40°C to +85°C (-40°F to +185°F) Process Temperature -40°C to +120°C (-40°F to +248°F) Adjustable Turndown Up to 100:1 Protocol HART® 7 Certifications ATEX, IECEx, SIL 2/3 (depending on configuration) Revision Rev-0C (may include firmware updates or minor hardware changes)

Model Foxboro FBM216 Module Type Discrete Output (DO) - Sourcing Type Number of Channels 16 Output Type Sourcing (24-48 V DC typical), Solid-State Output Voltage Range 20-60 V DC (depending on field supply) Current Rating 0.5 A per channel (max), with group current limits Load Compatibility Solenoids, relays, motor starters, indicator lamps System Compatibility Foxboro I/A Series DCS (requires FBM200 series fieldbase) Update Rate Millisecond response time Isolation Channel-to-channel and channel-to-bus isolation (500 V AC minimum) Power Supply Fieldbase-powered (5 V DC internal); field device power requires external supply Diagnostics Per-channel status LEDs, module health monitoring (OK/FAIL) Redundancy Support Yes (1:1 redundancy configuration) Connections Removable screw terminal block on fieldbase Operating Temperature 0°C to 60°C (32°F to 140°F) Enclosure Designed for installation in FBM fieldbase (rack-mounted) Certifications Designed for industrial environments (CE, ATEX depending on installation)

Model Foxboro IGP10-T22D1F-M1 Type Gauge Pressure Transmitter Measurement Range 0-1000 psi (0-69 bar) (typical for "T22" code) Output Signal 4-20 mA DC with HART® Protocol Accuracy ±0.075% of full scale (typical for IGP10 series) Power Supply 12-42 V DC (loop-powered) Process Connection 1/2" NPT Female Wetted Materials Diaphragm: 316L Stainless Steel; Seals: Viton® (FKM) Housing Rating NEMA 4X (IP66) Ambient Temperature -40°C to +85°C (-40°F to +185°F) Process Temperature -40°C to +120°C (-40°F to +248°F) Adjustable Turndown Up to 20:1 Stability ±0.1% of URL per year Protocol HART® Electrical Connection 1/2" NPT Conduit (for "F" code) Calibration Factory calibrated ("M1" suffix) Certifications CE, ATEX, IECEx (depending on variant)

Model Foxboro P0926AH-B Type Gauge Pressure Transmitter Measurement Range 0-1000 psi (0-69 bar) Output Signal 4-20 mA DC with HART® Protocol (Version 7) Accuracy ±0.065% of calibrated span (includes linearity, hysteresis, repeatability) Power Supply 10.5 to 42 V DC (loop-powered) Process Connection 1/2" NPT Female Wetted Materials Diaphragm: 316L Stainless Steel; Seals: Hastelloy C-276 Housing Rating NEMA 4X (IP66) Ambient Temperature -40°C to +85°C (-40°F to +185°F) Process Temperature -40°C to +120°C (-40°F to +248°F) Adjustable Turndown Up to 100:1 Stability ±0.1% of URL per year (10 years) Protocol HART® Certifications ATEX, IECEx, SIL 2/3 (optional) Isolation 1500 V AC (channel-to-ground)

Model Foxboro FBM237 Module Type Analog Input (AI) Number of Channels 8 independently configurable input channels. Input Types (Configurable) • 4-20 mA DC (current loop) • 0-10 V DC (voltage) • 1-5 V DC (voltage) • Thermocouple (T/C) types (e.g., J, K, T, E, R, S, B, N) • RTD (e.g., 100 Ohm Pt, 10 Ohm Cu) • Millivolt (mV) signals Resolution 16-bit (high resolution for precise measurement). Accuracy ±0.05% of reading for voltage/current inputs. Varies for T/C and RTD based on type and range. System Compatibility Foxboro I/A Series DCS. Must be installed in a compatible FBM fieldbase (e.g., FBM200 series). Update Rate Configurable, typically a scan of all channels within tens of milliseconds. Input Impedance > 1 MΩ for voltage inputs. 250 Ω (or other shunted resistor) for current inputs. Power Supply Powered by the fieldbase (typically ±12V and +5V from the power supply module). Isolation Channel-to-Channel: Yes, channels are isolated from each other. Channel-to-Bus: 500 V AC optical isolation protects the system bus from field-side faults. Field Wiring Field wiring is terminated to a removable screw terminal block on the associated fieldbase. A common return terminal is provided for groups of inputs. Diagnostics Includes comprehensive internal diagnostics for faults (e.g., module failure, open input circuit, over-range, under-range). LED Indicators Module status LEDs (e.g., OK, ACTIVE, FAIL) and often per-channel status indicators for faults. Environmental Designed for industrial environments. Operating temperature typically 0 to 60°C (32 to 140°F).