Parameters: Rated Voltage: 380-415 V AC (three-phase) Rated Current: 75 A Control Voltage: 24-240 V AC/DC Motor Power (kW): 37 kW at 400 V, 55 kW at 500 V Dimensions (H x W x D): 310 x 240 x 130 mm Weight: 2.8 kg Protection Class: IP20 Mounting: Wall mounting Ambient Temperature Range: -20 to +40°C Power Loss: 1.4 W (typical) Features: Soft start and stop capabilities Adjustable ramp-up and ramp-down times Built-in bypass contactor to reduce heat generation after motor start Integrated protection for overcurrent, phase failure, and more Easy to install and operate with minimal setup Communication capabilities for integration with control systems (depending on model and configuration)
Parameters: Rated Voltage: 380–690 V AC (Three-phase) Rated Current: 600 A Motor Power: Up to 500 kW at 400 V; up to 840 kW at 690 V (depending on application and voltage) Control Voltage: 24–240 V AC/DC Dimensions (H x W x D): 1080 x 670 x 430 mm Weight: Approx. 95 kg (varies with configuration) Protection Class: IP00 Ambient Temperature Range: -10 to +40°C (consult for higher ranges) Type of Mounting: Wall-mountable or as part of a panel solution Degree of Protection: IP20 (for indoor use; IP54 or higher available with optional kits) Integrated Communication Protocols: Modbus RTU, optional fieldbus (Profibus, Ethernet, etc.) Soft Start Time: Adjustable from 0.5 to 30 seconds Bypass Contactor: Integrated to reduce energy loss after motor start Integrated Protection Features: Overload protection Phase loss detection Overcurrent protection Ground fault detection (depending on configuration) Under-voltage and over-voltage protection
Parameters: Rated Voltage: 380-690 V AC (Three-phase) Rated Current: 600 A Motor Power: Up to 370 kW at 400 V; up to 600 kW at 690 V (depending on application and voltage) Control Voltage: 24–240 V AC/DC Dimensions (H x W x D): 810 x 480 x 290 mm Weight: Approx. 65 kg (varies depending on configuration) Protection Class: IP00 Ambient Temperature Range: -10 to +40°C (can be extended with cooling or specific configurations) Type of Mounting: Wall-mountable or part of a panel solution Degree of Protection: IP20 (for indoor use; higher protection classes available with optional kits) Communication Protocols: Modbus RTU, optional fieldbus options (Profibus, Ethernet, etc.) Soft Start Time: Adjustable from 0.5 to 30 seconds Bypass Contactor: Integrated bypass contactor for reduced power loss after motor start Protection Features: Overload protection Phase loss detection Overcurrent protection Ground fault detection (optional) Under-voltage and over-voltage protection
Parameters: Rated Voltage: 380-480 V AC (Three-phase) Rated Power: 55 kW (at 400 V) / 77 HP Rated Current: 77 A Input Voltage Range: 380-480 V ±10% Output Frequency Range: 0-500 Hz Control Method: V/F control, vector control, and sensorless vector control Overload Capacity: 150% of rated current for 60 seconds 110% of rated current for 1 minute Ambient Temperature Range: -10°C to +50°C (with derating above 40°C) Protection Class: IP20 (Standard) Enclosure: Wall-mountable Cooling: Forced ventilation with fan Weight: Approx. 27 kg Dimensions (H x W x D): 430 x 250 x 370 mm (with fan) Degree of Protection: IP20 (optional kits available for IP21 or higher) Input Control Voltage: 24 V DC Output Voltage: Same as input voltage (380-480 V)
Parameters: Rated Voltage: 380-480 V AC (Three-phase) Rated Power: 22 kW (at 400 V) / 52 A Rated Current: 52 A Input Voltage Range: 380-480 V ±10% Output Frequency Range: 0-500 Hz Control Method: V/f control, sensorless vector control Overload Capacity: 150% of rated current for 60 seconds 110% of rated current for 1 minute Cooling: Forced ventilation with fan Protection Class: IP20 (Standard) Ambient Temperature Range: -10°C to +50°C (derating above 40°C) Weight: Approx. 15.5 kg Dimensions (H x W x D): 320 x 195 x 220 mm Degree of Protection: IP20 (optional higher protection available) Control Voltage: 24 V DC (external supply) Motor Type Compatibility: Standard asynchronous motors, permanent magnet motors (optional)
Parameters: Rated Voltage: 380–480 V AC (Three-phase) Rated Power: 15 kW (at 400 V) / 20 HP Rated Current: 25.8 A Input Voltage Range: 380–480 V ±10% Output Frequency Range: 0–500 Hz Control Method: V/f control, sensorless vector control Overload Capacity: 150% of rated current for 60 seconds 110% of rated current for 1 minute Cooling: Forced ventilation with internal fan Protection Class: IP20 (Standard) Ambient Temperature Range: -10°C to +50°C (derating above 40°C) Dimensions (H x W x D): 270 x 175 x 210 mm Weight: Approx. 10.5 kg Degree of Protection: IP20 (optional higher protection available) Control Voltage: 24 V DC (external supply) Motor Type Compatibility: Standard asynchronous motors, permanent magnet motors (optional)
Parameters: Rated Voltage: 380-690 V AC (Three-phase) Rated Current: 600 A Motor Power: Up to 1050 kW at 690 V Up to 750 kW at 400 V Input Control Voltage: 24 V DC (external supply) Output Frequency: 0 to 500 Hz Cooling: Forced air cooling (with fan) Protection Class: IP00 (standard) Ambient Temperature Range: -10°C to +50°C (with derating above 40°C) Overload Capacity: 150% of rated current for 60 seconds 110% of rated current for 1 minute Dimensions (H x W x D): Approx. 1,020 x 740 x 500 mm Weight: Approx. 115 kg (depends on configuration) Degree of Protection: IP20 (for indoor use, optional higher protection classes available with kits) Mounting: Wall-mountable Control Method: Soft start with adjustable ramp-up and ramp-down, with full motor protection features. Key Features: Smooth Motor Start/Stop: The PSTX1050-600-70 ensures a smooth motor start, reducing mechanical shock and inrush current, which extends motor and system life. Advanced Protection Features: Overload protection Phase loss and phase imbalance protection Motor and system diagnostics Overvoltage and undervoltage protection Ground fault protection (depending on configuration) Short-circuit protection
Parameters: Rated Voltage: 380–690 V AC (Three-phase) Rated Current: 600 A Motor Power: Up to 45 kW at 400 V Up to 600 kW at 690 V Input Control Voltage: 24 V DC (external supply) Output Frequency: 0–500 Hz Cooling: Forced air cooling (with fan) Protection Class: IP00 (Standard) Ambient Temperature Range: -10°C to +50°C (with derating above 40°C) Overload Capacity: 150% of rated current for 60 seconds 110% of rated current for 1 minute Dimensions (H x W x D): Approx. 820 x 510 x 430 mm Weight: Approx. 65 kg (varies with configuration) Degree of Protection: IP20 (for indoor use, higher protection available with optional kits) Mounting: Wall-mountable Control Method: Soft start with adjustable ramp-up and ramp-down, with motor protection features.
Parameters: Rated Voltage: 690 V AC (maximum voltage rating) Rated Current: 63 A Rated Frequency: 50/60 Hz Number of Poles: 3P (Three-pole) Breaking Capacity: 10 kA (short-circuit breaking capacity) Switch Type: Rotary handle, manually operated IP Protection Class: IP65 (dust-tight and protected against water jets) Control Voltage: 230 V AC (for control circuit) Mounting Type: Panel mount Dimensions (H x W x D): Approx. 160 x 140 x 120 mm (varies slightly with configuration) Weight: Approx. 1.5 kg (depends on configuration) Connection Type: Screw terminal connections for ease of installation Operating Temperature Range: -25°C to +55°C (typical range for industrial environments) Certifications: UL, IEC, CE compliant Key Features: High Breaking Capacity: The switch can handle high fault currents (up to 10 kA), ensuring safe disconnection during short-circuit conditions. Rotary Handle: The handle allows for manual operation, providing clear visibility of the switch position (on/off) for operator safety. IP65 Protection: This high level of protection ensures the switch can be used in harsh environments where dust and water exposure is a concern. Safety Features: Provides a visible isolation to confirm the circuit is disconnected. This helps prevent accidental re-energizing of the equipment during maintenance or repair work. Durability: The device is designed for long-term use in industrial environments, with high-quality materials that ensure reliable operation over time. Versatile Applications: Suitable for use in various electrical panels, switchgear, industrial control systems, and HVAC systems. Compact Design: The compact size makes it easy to integrate into panels where space is limited. Applications: Industrial Electrical Distribution: Used in electrical panels and switchgear for isolating electrical circuits during maintenance. Commercial Buildings: Suitable for use in electrical systems requiring safe and reliable disconnection of power supplies. HVAC Systems: Ensures safe isolation of power in HVAC systems, preventing electrical hazards during service or repair. Power Control Systems: Used for controlling and isolating power to motors, generators, and other electrical devices in industrial settings. Renewable Energy Systems: Can be used in solar panel or wind turbine systems to safely isolate circuits for maintenance.
Parameters: Rated Voltage: 690 V AC (Maximum voltage rating) Rated Current: 63 A Number of Poles: 3P (Three-pole) Breaking Capacity: 10 kA (Short-circuit breaking capacity) Switch Type: Rotary handle, manually operated Control Voltage: 230 V AC (for control circuits) IP Protection Class: IP65 (Dust-tight and protected against water jets) Mounting Type: Panel mount Dimensions (H x W x D): Approx. 160 x 140 x 120 mm (varies slightly depending on configuration) Weight: Approx. 1.5 kg (depends on specific configuration) Connection Type: Screw terminals for electrical connections Operating Temperature Range: -25°C to +55°C (operating temperature range) Certifications: UL, IEC, CE Compliant
Parameters: Rated Voltage: 690 V AC (Maximum operating voltage) Rated Current: 63 A Number of Poles: 3P (Three-pole) Rated Frequency: 50/60 Hz Breaking Capacity: 10 kA (Short-circuit breaking capacity) Switch Type: Rotary handle, manually operated Control Voltage: 230 V AC (for control circuits) Protection Class: IP65 (Dust-tight and protected against water jets) Mounting Type: Panel mount Dimensions (H x W x D): Approx. 160 x 140 x 120 mm (varies slightly depending on configuration) Weight: Approx. 1.5 kg (depends on configuration) Connection Type: Screw terminals Operating Temperature Range: -25°C to +55°C (Standard operational temperature range) Certifications: UL, IEC, CE Compliant
Parameters: Rated Voltage: 690 V AC (Maximum rated voltage) Rated Current: 63 A Number of Poles: 3P (Three-pole switch) Rated Frequency: 50/60 Hz Breaking Capacity: 10 kA (Short-circuit breaking capacity) Switch Type: Rotary handle, manually operated Control Voltage: 230 V AC (for control circuits) IP Protection Class: IP65 (Dust-tight and protected against water jets) Mounting Type: Panel mount Dimensions (H x W x D): Approx. 160 x 140 x 120 mm (Dimensions may vary depending on configuration) Weight: Approx. 1.5 kg (Varies depending on configuration) Connection Type: Screw terminals for electrical connections Operating Temperature Range: -25°C to +55°C (Standard operational temperature range) Certifications: UL, IEC, CE Compliant