Technical Parameters Parameter Specification Product Type AC Contactor Model / Series UA63-30-00 Control Coil Voltage 220–230 V AC (50 Hz) / 230–240 V AC (60 Hz) Rated Operating Frequency (Coil) 50 Hz / 60 Hz Main Circuit Rated Operational Voltage (Ue) Up to 690 V AC Rated Insulation Voltage (Ui) 1000 V AC Rated Impulse Withstand Voltage (Uimp) 8 kV Number of Main Contacts 3 poles (3 NO — normally open) Auxiliary Contacts Optional / model dependent Rated Operational Current (AC-3 Ie) Approx. 63 A at 220–240 V AC Rated Operational Current (AC-1 Ie) Approx. 100–115 A at 690 V AC Rated Operational Power (AC-3 Pe) ~15–18 kW at 230 V AC Rated Operational Power (AC-6b Pe) ~25 kVAr at 230–240 V AC Mechanical Endurance High (designed for millions of operations) Electrical Endurance Suitable for frequent switching cycles Coil Power Consumption Holding and pull-in values suitable for rated coil voltage Operate Time Typical make and break times consistent with IEC contactor classes Terminal Type Screw / clamp type terminations Ambient Operating Temperature Designed for standard industrial ambient ranges (e.g., −40 °C to +70 °C) Standards Compliance Meets IEC contactor requirements for industrial AC switching
Technical Parameters Parameter Specification Product Type AC Contactor Model / Series UA63-30-11 Control Coil Voltage (Uc) 220–230 V AC at 50 Hz / 230–240 V AC at 60 Hz Rated Frequency (Coil) 50 / 60 Hz Main Circuit Rated Operational Voltage (Ue) Up to 690 V AC Rated Insulation Voltage (Ui) 1000 V AC Rated Impulse Withstand Voltage (Uimp) 8 kV Number of Main Contacts 3 poles (3 NO) Auxiliary Contacts Optional (model dependent) Rated Operational Current (AC-3 Ie) ~65 A at 220–240 V AC Rated Operational Current (AC-1 Ie) ~115 A at 690 V AC Rated Operational Power (AC-3 Pe) ~18.5 kW at 230 V AC Rated Operational Power (AC-6b Pe) ~25 kVAr at 230–240 V AC Mechanical Durability Approx. 10 million operations Electrical Switching Frequency Up to ~3600 cycles/hour Coil Consumption Holding ~18 VA; Pull-in ~180 VA Operate Time Approx. 8–27 ms (make) / 4–11 ms (break) Terminal Type Screw / clamp terminals Environmental / Operating Temp Typically −40 °C to +70 °C Standards Compliance IEC 60947-4-1 compliance
Technical Parameters Parameter Specification Product Type AC Contactor Model / Series UA110-30-11 Control Coil Voltage 220–230 V AC (50 Hz) / 230–240 V AC (60 Hz) Operating Frequency 50 / 60 Hz Main Circuit Rated Operational Voltage Up to 1000 V AC Rated Operational Current (AC-3) Approx. 110 A at 220–240 V AC Rated Operational Power (AC-6b) Approx. 40–45 kVAr at 230–240 V AC Rated Insulation Voltage 1000 V AC Rated Impulse Withstand Voltage 8 kV Short-time Withstand Current (Icw) Approx. 800 A for 10 s (cold state) Making Capacity Approx. 10 × Ie (AC-3) Breaking Capacity Approx. 8 × Ie (AC-3) Number of Poles 3 (plus auxiliary contacts when fitted) Terminal Type Screw or cable clamp connections Mechanical Endurance High cycles (designed for long life) Ambient Operating Temperature Typically −40 °C to +70 °C
Technical Parameters Parameter Value Product Series ABB SACE Tmax XT Frame Size XT2 Frame Rating 160 A Rated Current (In) 40 A (adjustable) Trip Unit TMA – Thermal Magnetic Adjustable Thermal Overload Adjustment 28 – 40 A Magnetic Short-Circuit Adjustment 300 – 400 A Number of Poles 4P Breaking Capacity Class H (High breaking capacity) Rated Operational Voltage (Ue) Up to 690 V AC Rated Frequency 50 / 60 Hz Rated Insulation Voltage (Ui) 1000 V Rated Impulse Withstand Voltage (Uimp) 8 kV Rated Ultimate Short-Circuit Breaking Capacity (Icu) Up to 150 kA @ 400 V AC Rated Service Short-Circuit Breaking Capacity (Ics) 100% of Icu Mounting / Execution Fixed Terminal Type Front terminals (FF) Protection Functions Overload and short-circuit protection Standard Compliance IEC / EN 60947-2 Operating Mechanism Manual Typical Applications Power distribution, feeders, industrial panels
Parameters: Product Type: Molded Case Circuit Breaker (MCCB) Model: F1S1250 AR1 Rated Current (In): 1250A Rated Voltage: 690V (AC) Rated Frequency: 50/60 Hz Number of Poles: 3P (Three-Phase) Interrupting Capacity (Icu): 50kA (or higher depending on configuration) Protection Type: Thermal-Magnetic (Overload and Short-Circuit Protection) Thermal Protection: Adjustable thermal release for overload protection. Magnetic Protection: Adjustable magnetic release for short-circuit protection. Adjustable Settings (AR1): Adjustable protection settings for overload current and short-circuit trip values. Service Type: Indoor and outdoor installation (depending on the configuration and protective enclosure) Operating Temperature: -5°C to +40°C (standard range for ABB circuit breakers) Ingress Protection (IP Rating): IP20 (for indoor use), IP65 (if designed for outdoor use) Dimensions: [Insert dimensions, e.g., 160mm x 120mm x 250mm] (dependent on configuration) Weight: [Insert weight, e.g., 7-12 kg]
Parameters: Product Type: Vacuum Circuit Breaker (VCB) Model: VD4/Z 12.12.40 Rated Voltage: 12 kV (medium-voltage application) Rated Current: 630A (standard), or configurable to suit specific system needs Interrupting Capacity (Icu): 40 kA (at rated voltage) Rated Frequency: 50/60 Hz Number of Poles: 3P (Three-Phase) Service Type: Indoor installation (can be used in outdoor enclosures with appropriate protection) Operating Temperature: -25°C to +40°C (typical for ABB circuit breakers) Mechanical Endurance: 30,000 operations (or more depending on the specific configuration) Electrical Endurance: 10,000 operations (or more) Arc Quenching Medium: Vacuum Standards Compliance: IEC 60947-2, UL 489, CE, and other international standards Ingress Protection (IP Rating): IP20 (for indoor installations), IP65 (if designed for outdoor use) Dimensions: [Insert dimensions, e.g., 300mm x 250mm x 180mm] (specific dimensions depending on configuration) Weight: [Insert weight, e.g., 20-30 kg depending on configuration]
Parameters: Product Type: Protection Relay / Circuit Breaker Rated Current (In): 1600A Number of Poles: 3P (Three-Phase) Interrupting Capacity (Icu): Typically 50kA or higher, depending on the model and application. Protection Type: PR121/P-LSI (Long-time, Short-time, Instantaneous protection) Long-time (L): Adjustable overload protection with time delay Short-time (S): Adjustable short-time protection for transient conditions Instantaneous (I): Instantaneous protection for high short-circuit currents Wide Monitoring Platform (WMP): Continuous system health monitoring, fault detection, and diagnostics Neutral Switching Technology (NST): Ensures safe switching of neutral in three-phase systems, improving protection Rated Voltage: 400V or higher (depending on system configuration) Frequency: 50/60Hz Operating Temperature: -5°C to +40°C (typical for ABB industrial equipment) Standards Compliance: IEC 60947-2, UL 489, CE, and other international standards Mounting Type: Panel mount, or as part of a larger switchgear assembly Ingress Protection (IP Rating): IP20 (for indoor use), IP65 (if designed for outdoor use) Communication Protocols: Likely supports Modbus, Ethernet, or other industrial communication protocols for SCADA integration Dimensions: [Insert dimensions, e.g., 300mm x 200mm x 150mm] Weight: [Insert weight, e.g., 10-15 kg]
Parameters: Product Type: Protection Relay / Control Device Rated Voltage: [Insert rated voltage, e.g., 230V, 400V, etc.] Rated Current: [Insert rated current, e.g., 10A, 32A, 50A, etc.] Frequency: 50/60Hz Overcurrent Protection: Yes, with adjustable settings for fault current detection and time delay Short-Circuit Protection: Yes, with customizable trip settings for quick disconnection during fault conditions Earth Fault Protection: Yes, protecting against leakage currents and ground faults Communication Protocols: Supports Modbus, Ethernet, or other protocols for integration with SCADA or automation systems Mounting Type: Panel mount or DIN rail mount (depending on configuration) Standards Compliance: IEC 60947-2, UL 489, and other global standards for safety and performance Operating Temperature: -5°C to +40°C (typical range for ABB protection relays) Ingress Protection (IP Rating): IP20 (for internal use) or IP65 (for outdoor use) Dimensions: [Insert dimensions, e.g., 120mm x 80mm x 60mm] Weight: [Insert weight, e.g., 0.5 kg]
Parameters: Product Type: Molded Case Circuit Breaker (MCCB) Rated Current (In): 1250A Number of Poles: 3P (Three-Phase) Rated Voltage: 400V (or higher, depending on the system configuration) Interrupting Capacity (Icu): 50kA (or other depending on the model) Protection Type: LSI (Long-time, Short-time, Instantaneous) Long-time (L): Adjustable delay for overload protection Short-time (S): Adjustable delay for transient overloads and short-circuits Instantaneous (I): Instantaneous protection for short circuits Frequency: 50/60Hz Standards Compliance: IEC 60947-2, UL 489, CE, and other international standards for electrical safety Mounting Type: DIN Rail or Panel mount (depending on installation) Operating Temperature: -5°C to +40°C (standard for ABB breakers) IP Rating: IP20 (for internal use) or IP65 (if designed for outdoor use) Dimensions: [Insert dimensions, e.g., 320mm x 160mm x 130mm] Weight: [Insert weight, e.g., 7-10 kg, depending on the model]
Parameters: Product Type: Protection Relay / Control Device Rated Voltage: [Insert rated voltage, e.g., 230V, 400V, etc.] Rated Current: [Insert rated current, e.g., 10A, 32A, 50A, etc.] Frequency: 50/60Hz Overcurrent Protection: Yes, with adjustable settings for fault current detection Short-Circuit Protection: Yes, with configurable trip time Ground Fault Protection: Yes, providing protection against earth leakage and ground faults Mounting Type: Panel mount or DIN Rail mount (depending on configuration) Standards Compliance: IEC 60947-2, UL 489, or other applicable international standards Operating Temperature Range: -5°C to +40°C (typical range for ABB protection devices) Ingress Protection (IP Rating): IP20, IP65 (depending on the model) Dimensions: [Insert dimensions, e.g., 120mm x 80mm x 60mm] Weight: [Insert weight, e.g., 0.5 kg] Electrical Endurance: [Insert number of operations, e.g., 10,000 cycles]
Parameters: Product Type: Protection Relay / Circuit Breaker Rated Voltage: 6kV (typical for medium-voltage systems) Rated Current (In): 5000A (current rating depending on the configuration) Interrupting Capacity (Icu): 25kA (or other depending on the model) Short-Circuit Protection: Yes, with adjustable settings for fault current detection and trip time Overload Protection: Yes, with configurable time delay Earth Leakage Protection (LSIG): Yes, including Leakage, Short-circuit, Overload, and Ground Fault protection WMP (Wide Monitoring Platform): Real-time monitoring, fault diagnostics, and reporting for enhanced system performance Neutral Switching Technology (NST): Ensures safe neutral switching for three-phase systems Number of Poles: 3P (Three-Phase) Rated Frequency: 50/60Hz Mounting Type: Panel mount or switchgear integration Standards Compliance: IEC 60947-2, UL 489, and other international standards Operating Temperature Range: -5°C to +40°C (typical for ABB medium-voltage equipment) Ingress Protection (IP Rating): IP20 (for indoor use) or IP65 (if rated for outdoor installation) Dimensions: [Insert dimensions, e.g., 120mm x 100mm x 90mm] Weight: [Insert weight, e.g., 5 kg]
Parameters: Product Type: Vacuum Circuit Breaker (VCB) Model: VD4M1206-25 Rated Voltage: 12kV Rated Current: 630A (or other specific current ratings based on configuration) Interrupting Capacity (Icu): 25kA (short circuit interrupting capacity) Rated Frequency: 50/60Hz Number of Poles: 3P (Three-Phase) Mechanical Endurance: 30,000 operations Electrical Endurance: 10,000 operations Operating Mechanism: Spring-operated or motor-driven mechanism for fast and reliable switching Service Type: Indoor installation (typically in electrical switchgear and substations) Temperature Range: -25°C to +40°C (operating temperature range) Mounting Type: Fixed or withdrawable (depending on the configuration) IP Rating: IP20 (for internal use in switchgear) Arc Quenching Medium: Vacuum Weight: Approximately 100-150 kg (depending on the configuration)