Industrial Controller
All product are in stock,guaranteed delivery within 3-7 days.
Infinite Innovation, the Future of Industrial Control Systems
Infinite Innovation, the Future of Industrial Control Systems
PRODUCT HOME>>PRODUCT
PRODUCT

PRODUCT

PICTURE

BRAND

DESCRIBE

STOCK

DOWNLOAD

Key Parameters Category Parameter Description / Typical Values Valve Body & Size Valve Body Style Single-ported, top-guided globe valve. Size Range 1/2 inch (DN15) to 2 inches (DN50). End Connections Flanged (ANSI Class 150 & 300). Pressure & Temperature Pressure Rating ANSI Class 150 and 300. Temperature Range Standard: -20°F to +450°F (-29°C to +232°C). Flow Characteristics Flow Characteristics Linear or Equal Percentage (via plug design). Flow Coefficient (Cv) A range of Cv values available based on trim size. Leakage Class Leakage Class ANSI/FCI 70-2 Class IV (standard metal seat). Class VI available with soft seats. Materials Body Materials Carbon Steel (WCB), Stainless Steel (CF8/304, CF8M/316). Trim Materials Stainless Steel (standard). Actuator Actuator Type Typically paired with a compact Fisher Baumann 1051/1052 pneumatic actuator or other spring-diaphragm actuators.

Key Parameters Category Parameter Description / Typical Values Pressure Ratings Maximum Inlet Pressure (P1) 125 psig (8.6 bar). Outlet Pressure (P2) Range Adjustable via spring selection. Common ranges span from 3.5" w.c. to 20 psig (approx. 0.87 kPa to 1.4 bar). Capacity Flow Coefficient (Cv) Low to moderate Cv, suitable for its intended applications. Size & Connections Pipe Size Typically 1/2 inch to 1-1/4 inch. End Connections Threaded (NPT). Materials Body Material Aluminum. Internal Components Stainless Steel, Synthetic Rubber Diaphragm. Safety Features Overpressure Protection (OPP) Integral Internal Relief Valve is a common optional feature. Environment Operating Temperature Standard for gas service (e.g., -20°F to 150°F / -29°C to 66°C).

Key Parameters Category Parameter Description / Typical Values Pressure Ratings Maximum Inlet Pressure (P1) Up to 1440 psig (100 bar). Outlet Pressure (P2) Range Configurable via pilot selection. Designed for high outlet pressures, often ranging from hundreds to over a thousand psig. Capacity Flow Coefficient (Cv) Extremely high Cv values. For example, a 6" P700 can have a Cv of over 1500. Accuracy & Droop Excellent, typically within ±1-2% of the set point due to the pilot-operated design. Size & Connections Pipe Size 2 inches (DN50) to 8 inches (DN200). End Connections Flanged (ANSI Class 600, 900, 1500). Materials Body Material Forged Steel (standard for high pressure). Trim Materials Stainless Steel. Pilot & Safety Pilot Types Reducing Pilot, Monitor Pilot, Dome-Loaded Pilot. Safety System Almost always installed upstream with a Fisher PSL or PSS Slam-Shut Valve for critical overpressure protection. Environment Operating Temperature Standard: -20°F to +150°F (-29°C to +66°C).

Key Parameters Category Parameter Description / Typical Values Pressure Ratings Maximum Inlet Pressure (P1) Up to 400 psig (28 bar). Outlet Pressure (P2) Range Highly configurable via pilot selection. Common ranges from a few psig up to 250 psig. Capacity Flow Coefficient (Cv) High Cv values. For example, a 6" P650 can have a Cv of over 1000. Accuracy & Droop Excellent, typically within ±1-2% of the set point. Size & Connections Pipe Size 2 inches (DN50) to 12 inches (DN300). End Connections Flanged (ANSI Class 150 to 600). Materials Body Material Cast Iron or Ductile Iron. Trim Materials Stainless Steel. Pilot & Safety Pilot Types Reducing Pilot, Monitor Pilot, Dome-Loaded Pilot. Safety System Designed to be paired with external Slam-Shut Valves (PSL/PSS) for absolute overpressure protection. Environment Operating Temperature Standard: -20°F to +150°F (-29°C to +66°C).

Key Parameters Category Parameter Description / Typical Values Input & Control Control Signal 4-20 mA DC. Control Function Electronic setpoint for pressure reduction. Pressure Ratings Maximum Inlet Pressure (P1) 400 psig (28 bar). Outlet Pressure (P2) Range Determined by the internal pilot spring. Adjustable via the 4-20 mA signal across the spring's range. Capacity Flow Coefficient (Cv) High Cv values, similar to other regulators in its size class (e.g., a 2" size has a Cv of ~65). Size & Connections Pipe Size 3/4 inch to 4 inches. End Connections Threaded (NPT) or Flanged. Materials Body Material Cast Iron. Internals Stainless Steel. Electrical I/P Transducer Air Supply Requires a clean, dry instrument air supply (typically 20-100 psig).

Key Parameters Category Parameter Description / Typical Values Pressure Ratings Maximum Inlet Pressure (P1) 125 psig (8.6 bar). Outlet Pressure (P2) Range Adjustable via spring selection. Common ranges span from 3.5" w.c. to 20 psig (approx. 0.87 kPa to 1.4 bar). Capacity Flow Coefficient (Cv) Low to moderate Cv, suitable for its intended applications. Size & Connections Pipe Size Typically 1/2 inch to 1-1/4 inch. End Connections Threaded (NPT). Materials Body Material Aluminum. Internal Components Stainless Steel, Synthetic Rubber Diaphragm. Safety Features Overpressure Protection (OPP) Integral Internal Relief Valve is a common optional feature. Environment Operating Temperature Standard for gas service (e.g., -20°F to 150°F / -29°C to 66°C).

Key Parameters Category Parameter Description / Typical Values Compatibility Supported Protocols HART® (Highway Addressable Remote Transducer). Compatible Instruments Fisher FIELDVUE Digital Valve Controllers and other HART communication devices. Electrical Power Supply Loop-powered (draws power from the 4-20 mA loop of the connected HART instrument). Loop Requirements Requires a minimum loop voltage and resistance to operate (e.g., typically > 11 VDC and < 1100 Ω). Connectivity Computer Connection USB or Serial (RS-232) via appropriate cables. Field Connection Standard test lead connectors. Software Required Software Fisher FIELDVUE DVC Setup and Diagnostics Software or Emerson AMS Device Manager. Environment Operating Temperature Standard for field use (e.g., 32°F to 140°F / 0°C to 60°C).

The Eaton NZM3-XR208-240AC is a high-performance molded case circuit breaker with electronic trip unit, designed for critical power distribution applications requiring advanced protection and monitoring capabilities.

The Eaton NZMN2-A250-NA UL is a UL-listed, 250A molded case circuit breaker designed for reliable circuit protection in commercial and industrial power distribution systems. This 2-pole MCCB combines robust construction with advanced thermal-magnetic trip technology.

The Eaton RGH65K 2000A 3P is a heavy-duty air circuit breaker designed for main power distribution in large industrial and commercial facilities. With a 2000A rating and 65kA interrupting capacity, this breaker provides reliable protection for critical high-current circuits.

The Eaton NSX 4P 80A is a premium 4-pole molded case circuit breaker from Eaton's NSX series, designed for advanced circuit protection in commercial and industrial applications requiring neutral pole protection.

The Eaton NSX 4P 80A is a premium 4-pole circuit breaker designed for critical power distribution systems requiring full neutral protection. Part of Eaton's award-winning NSX range, this MCCB combines advanced protection technology with smart monitoring capabilities.